NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Diagram A: Top View-Parallel Installation Diagram B: Side View-Alcove Installation

PIPE INSTALLATION A B(1) C D(1) E† F(1,4) G(4) H (2) I

(6)

Double Wall Residential or Alcove 12"
305mm
9-1/2"
241mm
24"
610mm
14"
356mm
8"
200mm
7-1/4”
184mm
18"
450mm
USA-43-1/2”
CAN-1308mm
USA-53”
CAN-1346mm
6” or 8”
Diameter
Mobile Home* 12"
305mm
9-1/2"
241mm
24"
610mm
14"
356mm
8"
200mm
7-1/4”
184mm
18"
450mm
USA-43-1/2”
CAN-1308mm
USA-53”
CAN-1346mm

PIPE INSTALLATION J (2) K L M N

u

T

(6)

Double Wall Residential or Alcove USA-38”
CAN-1130mm
20”
508mm
USA-0”
CAN-200mm
72"
1829mm
39-1/2"
1003mm
USA-68”
CAN-1727mm
6” or 8”
Diameter
Mobile Home* USA-38”
CAN-1130mm
20”
508mm
USA-0”
CAN-200mm
72"
1829mm
39-1/2"
1003mm
USA-68”
CAN-1727mm
insTallaTion clearances - refer To Diagrams a, B & c

Alcove, Residential, or Mobile Home

6” or 8” Double Wall Air Cooled

Footnotes:
1 - These dimensions to the stove body are for
reference only. Actual distances should be
measured from the stove’s flue collar.
2 - Minimum noncombustible hearth pad
dimensions.
3 - Shield shall be attached to the rear of the
stove pipe with a 1” air space and must run
from the top of the stove to the ceiling.
4 - Not applicable to alcove installations.
5- In corner applications, when installed
at minimum back wall clearances, the
required floor protection is dimensioned
off the back plane of the stove, therefore
the floor protection required off the back
corners (at a 45 degree angle) only needs
to extend to the wall. This situation will
only occur in CANADA installations.
6- Reference dimension only, to assist in
planning the installation.
Clearances to connector pipe shall be mea-
sured from the flue collar of the stove.
Diagram C: Top View-
Corner Clearance, Stove & Flue to Wall
† USA=8" (200mm) from door opening, Canada=8" (200mm) from sides and back of unit
u
Dimensions to Stove Body
* Mobile Home - USA only
B A L
C
D
†E †E
K
Floor Protection
H
I
J
M
N
I
Floor Protection
K
T
J
H
Floor Protection
F
F
GG
Combustible Wall

48”

Max.

Depth