4 - White Rodgers 36E/36F Gas Valve - Switch gas valve lever to OFF.

Honeywell VR8205 Gas Valve - Turn knob on gas

valve clockwise to OFF. Do not force. 5 - Replace the upper access panel.

Filters

This unit is not equipped with a filter or rack. A field-pro- vided high-velocity filter is required for the unit to operate properly.

A filter must be in place whenever the unit is operating.

Seasonal Inspections

A qualified service technician should inspect the complete system each season (heating and cooling). The following maintenance procedures should only be conducted by a qualified service technician. Do not attempt to service

the unit in any way.

Venting System

WARNING

Asphyxiation Hazard

The exhaust vent for this furnace must be securely connected to the furnace flue collar at all times.

For your safety and to fulfill the terms of the limited warranty, a qualified service technician must annual- ly inspect this furnace and its vent system.

Annually (before heating season) inspect furnace venting system, vent cap, heat exchanger, and burners for corro- sion, deterioration, or deposits of debris. Remove any ob- structions.

Inspect the furnace venting system to make sure it is in place, physically sound, and without holes, corrosion, or blockage. Vent connector must be in correct position, sloped upward and be physically sound without holes or excessive corrosion.

Inspect the furnace return air duct connection to ensure duct is sealed to the furnace and terminates outside the space containing the furnace.

Inspect the physical support of the furnace to guarantee that it is sound without sagging, cracks or gaps around base and it maintains seal between base and support.

During a seasonal check the service technician will inspect the indoor blower and the burner flames along with the venting system.

Blower

Check blower wheel for any debris and clean, if necessary. Blower motor is pre-lubricated for extended bearing life. No further lubrication is needed.

Burner Flame

CAUTION

To ensure proper operation, a qualified technician should annually check the burner flame.

Service Reminder

Call your Lennox service technician if the unit will not oper- ate. Before calling, always check the following to be sure service is required:

1 - Check that electrical disconnect switches are ON.

2 - Check room thermostat for proper setting.

3 - Replace any blown fuses or reset circuit breakers.

4 - Gas valve should be ON.

5 - Air filter should not be plugged, which will limit air flow. 6 - Is gas turned on at meter?

7 - Is manual main shut-off valve open?

Record the model and serial number of the furnace. These numbers are on the unit nameplate, which is located below the burners.

Serial Number __________________

Model Number __________________

Safety Precautions

If you discover any of the following, shut down your unit, and contact a Lennox dealer for an inspection by a-qualified technician.

If you repeatedly hear any new or unfamiliar sounds while your unit is operating, there may be a problem. For example, poorly performing burners can produce unfa-

-miliar noises.

If you smell any unusual odors, your unit may be operat- ing improperly. For example, units can give off unfamil- iar odors if components are required to operate in ab-

-normal conditions.

Look for visible signs of a malfunctioning unit. Examples include unusual amounts of condensate on windows in- side your house, visibly burnt components or unusual

-dirt or rust accumulations on the vent pipe or in the unit.

If you experience headache, nausea, fatigue, or dizzi- ness, the cause could be exposure to carbon monoxide gas. This is often misdiagnosed as the flu because symptoms are similar. If you suffer from flu-like symp- toms that are exaggerated at home, but seem to sub- side while you are away from the house, exposure to carbon monoxide could be the cause.

Your vigilance may pay off in early detection of a problem before either personal injury or property damage occurs. Do not hesitate to contact a qualified service technician as an investment in your well being.

Page 5

Page 5
Image 5
Lennox International Inc G40UH(X) manual Filters, Seasonal Inspections, Service Reminder, Safety Precautions

G40UH(X) specifications

Lennox International Inc. has long been a recognized leader in the heating, ventilation, and air conditioning (HVAC) industry, providing customers with innovative, high-efficiency solutions. One of its standout products is the G40UH(X) series, a gas furnace that exemplifies modern engineering and energy efficiency. The Lennox G40UH(X) is designed to offer powerful heating capability while maintaining eco-friendly performance and reliability.

One of the main features of the G40UH(X) is its multi-speed blower motor, which not only enhances comfort levels but also operates quietly and efficiently. This furnace utilizes advanced technology to provide better airflow and even heating throughout the space, reducing temperature fluctuations and ensuring that every corner of a home remains comfortable regardless of external weather conditions.

The G40UH(X) series includes a variable-speed gas valve, allowing for precise control over heating output. This feature enables the furnace to adjust its heating capacity in response to the specific needs of the home, optimizing energy consumption and reducing utility costs. Its efficiency rating of up to 96% AFUE (Annual Fuel Utilization Efficiency) means that a significant majority of the energy consumed is effectively converted into heat, making it an environmentally friendly choice.

In terms of design, the G40UH(X) is compact and versatile, making it suitable for various home layouts. Its quiet operation is another significant benefit, as it is engineered to minimize noise, ensuring that it does not disrupt daily activities while efficiently heating the home.

Additional characteristics of the G40UH(X) include compatibility with the Lennox iComfort S30 Smart Thermostat. This integration allows homeowners to control the system remotely, optimizing performance and ensuring maximum comfort. Safety is also a top priority with features such as a secondary heat exchanger and an integrated carbon monoxide sensor, providing peace of mind to users.

Overall, the Lennox G40UH(X) gas furnace embodies quality, efficiency, and innovative design, making it a popular choice for homeowners looking to enhance their heating systems. With its combination of advanced technology, substantial performance, and user-friendly features, the G40UH(X) remains an ideal solution for modern indoor comfort.