CARE AND OPERATION

PRIMARY AIR DRAFT CONTROL

Use the air control adjustment tool (provided) to adjust the air controls per the following instructions.

Air Control / Ash Pan Removal Tool

The primary combustion air delivery is controlled by the Primary Air Draft Control Assembly (located above the front door). The heat output can be controlled by sliding the control to a higher or lower heat output setting using the Air Control Tool Provided (See Primary Air Draft Control below).

The fuel, the amount of heat and burn times desired, the type of installation are all variables that will affect the control setting. The same control settings in a variety of installations will produce different results. You will need to try different settings so you can learn how much heat to expect and how long the fire will burn.

With the air control tool (provided in accessory package) the control can be adjusted to the heat output desired (see following illustration).

Primary Air Draft Control

Using the air control tool (provided) slide the control

above door to adjust burn rate.

Lower Burn / Slide Left

Higher Burn / Slide Right

Adjusting Burn Rate:

The primary air draft control located above the front door can be adjusted to the right for higher temperatures and to the left for lower temperatures.

Generally, you will want to set the draft control somewhere in the low or medium range

Tips - Adjust the primary air control to a medium to low setting for a slow and more efficient burn. When burning on a higher setting, it is more efficient to burn with a bright but not roaring fire.

START UP AIR CONTROL (IGNITION BOOSTER)

To facilitate lighting, your stove is equipped with an ignition booster, which brings start-up air to the fire for a short period of time. This can be especially helpful when your chimney is cold. The ignition booster can also be used to allow the fire to recover quickly following refuel- ling.

Start-Up Air Control

PROVIDES SUPPLEMENTAL PRIMARY AIR. DO NOT LEAVE THE START-UP AIR CONTROL OPEN FOR MORE THAN FIVE MINUTES.

Stove

Back

Slide

Start-Up Air

to

Control Module.

Open

 

Before Initial Lighting

1.Using the air control tool open the start-up air control by pulling the lever outwards (see illustration above).

2.Load fuel into the firebox and light the fire as usual (see How To Start And Maintain A Fire on page 16)

DO NOT LEAVE THE START-UP AIR CONTOL IN THE OPEN POSITION FOR MORE THAN FIVE MINUTES (THIS COULD RESULT IN DANGEROUS OVERFIRING WHICH IS NOT COVERED UNDER THE WARRANTY). CLOSE BY PUSHING THE LEVER INWARDS.

See How to Start And Maintain A Fire on page 16

PAGE 15