INSTALLATION

See Pipe Manufacturers Instructions For Installation Requirements Of Venting Components And Vent Clearances.

SINGLE WALL PIPE

 

DOUBLE WALL PIPE

 

 

 

Using 6” Diameter Single Wall Connector Pipe

 

(Approved for Model CI2000HT Only)

 

 

 

Chimney

 

Using 6” Diameter Type L-Vent Connector Pipe

 

 

 

 

 

 

Termination

 

 

 

 

 

Cap

 

 

Termination

 

 

 

 

Cap with

 

Storm

 

 

Spark Arrestor

 

 

 

 

 

 

Collar

 

3 Feet

 

 

 

 

 

 

 

 

 

 

Minimum

 

 

 

Roof

 

Storm Collar

 

 

 

 

Flashing

 

 

 

 

 

Flashing

 

 

 

 

 

 

 

 

 

Ceiling Support

 

 

 

 

 

 

 

 

Assembly

 

 

 

 

 

 

 

 

 

Support

 

 

Minimum of 12-15' of

 

Box

 

Slip

 

 

 

Flue

to achieve a

 

 

 

Adapter

 

 

 

stable draft.

 

 

 

 

 

 

 

 

 

 

DVL Close

 

 

 

 

Clearance

 

 

 

 

Connector

 

 

 

 

Pipe

 

7 Feet

Minimum

Chimney

Connector

6" x 24" 24-gage black steel or 26 gage blued steel single wall pipe

Floor

Protector

IMPORTANT NOTES:

Minimize the use of elbows (30°, 45° or 90°) - Offsets in the venting system are very restrictive and will inhibit the draft (i.e. You will lose approximately 5 feet of effective draft for every 90 degrees of direction change). This appliance re- quires 12 to 15 feet of effective draft for optimum perform- ance (see Draft Requirements on page 12).

First section of pipe must be vertical - Use as much straight vertical pipe directly above the appliance as possible be- fore using an elbow (a 2’ to 3’ initial vertical rise is sug- gested).

PAGE 13