•To be installed and/or used in accordance with appropriate electrical codes and regulations.
•If you are unsure about any part of these instructions, consult a qualified electrician.
•To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer- operated appliance.
•Use with incandescent or 120V halogen fixtures only.
•Vizia™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ remotes for multi-location dimming.
•Use only one (1) Vizia™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will turn the light on at the brightness level selected at the dimmer.
•Dimmer may not operate with dioded lamps (Sylvania Designer 16™ or Philips PAR-16™).
•Total minimum load must exceed 40W.
•Dimmer may feel warm to the touch during normal operation.
•Recommended minimum wall box depth is 2-1/2".
•Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
•Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
•Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
Push in side at tab | Line up tabs and |
to release | press in side to |
| attach |
Installing Dimmer by itself or with other devices:
If installing Dimmer in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-device application, proceed as follows:
MULTI-DEVICE APPLICATION:
In multi-dimmer installations, the reduction of the dimmer’s capacity is required. Refer to the chart for maximum load per dimmer.
Step 2 Identifyingcommon): your wiring application (most
NOTE: If the wiring in the wall box does not resemble any of these configurations, consult a qualified electrician.
Side Wire Connection | Back Wire (either hole may |
be used) |
Side wire terminals accept | Back wire openings use #14-12 |
#14 AWG solid copper wire only. AWG solid copper wire only.
• Make sure that the ends of the wires from the wall box are |
straight (cut if necessary). |
• Remove insulation from each wire in the wall box as shown. |
• For Single-Pole Application, go to Step 4a. |
• For 3-Way Coordinating Remote (no LEDs) Application, go |
to Step 4b. |
• For 3-Way Matching Remote (with LEDs) Application, go to |
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
•Green or bare copper wire in wall box to Green terminal screw.
•Line Hot wall box wire to terminal screw marked "BK".
•Load wall box wire to terminal screw marked "RD".
•Dimmer terminal screw marked "YL/RD" should have Red insulation label affixed.
NOTE: If insulating label is not affixed to terminal screw marked "YL/RD", use electrical tape to cover.
•Proceed to Step 5.
Step 4b 3-Way Wiring with Coordinating Dimming or Switching Remote (no LEDs)
(Coordinating Dimming Remote Depicted)
Coordinating Remote | Dimmer |
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer can be installed on either the Line or Load side of the 3-way circuit.
NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
•Green or bare copper wire in wall box to Green terminal screw.
•Line Hot (common) wall box wire identified (tagged) when removing old switch to terminal screw marked “BK”.
•First Traveler wall box wire to terminal screw marked “RD” (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked “RD”.
•Remove Red insulating label from terminal screw marked “YL/RD”.
•Second Traveler wall box wire to terminal screw marked “YL/RD” (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked “YL/RD”.
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
| | | More than |
Cat. No. | Single | Two Devices | 2 Devices |
| | | | |
VZIØ6 | 600W | 500W | 400W |
| | | | |
Single-Pole | 3-Way |
1. | Line (Hot) | 1. | Line or Load (See important |
2. | Neutral | | instruction below) |
3. | Ground | 2. | Neutral |
4. | Load | 3. | Ground |
4.First Traveler – note color
5.Second Traveler – note color NOTE: For matching remote w/LEDs installation, the First Traveler becomes Line Hot.
IMPORTANT: For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the dimmer wall box and remote wall box.
Step 4a Single-Pole Wiring Application:
Terminal | BK | 1 | 2 |
|
Screw marked | | | |
Black (BK) | | 3 | |
| | |
Terminal | YL/RD RD | |
Screw marked | | 4 | |
Yellow/Red | | Terminal | |
(YL/RD) | | |
| Screw marked | |
| | |
| | Red (RD) | |
| Terminal Label: | |
| Use Terminal for 3-Way or More Applications Only. |
| For Single-Pole Applications, Do Not Remove This |
| Label. | | |
BK | | 1 | Terminal | BK | 1 | |
| | 2 |
| | 2 | Screw marked | | |
| | | Black (BK) | | 3 | |
| | 3 | | | |
| | | | 4 | |
| RD | | Terminal | YL/RD | |
| 4 | RD | |
YL/RD | | Screw marked | | | |
| | | | 5 | |
| | 5 | Yellow/Red | | |
| | | (YL/RD) | | | |
| | | | | Terminal | |
| | | | Screw marked | |
| | | | | Red (RD) | |
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300ft.
•Green or bare copper wire in wall box to Green terminal screw.
•Load wall box wire identified (tagged) when removing old switch to terminal screw marked “BK”.
•First Traveler wall box wire (note color as above) to terminal screw marked “RD”. This traveler from the remote must go to the terminal screw on the dimmer marked “RD”.
•Second Traveler wall box wire (note color as above) to terminal screw marked “YL/RD”. This traveler from the remote must go to the terminal screw on the dimmer marked “YL/RD”.
•Remote terminal screw marked "WH" should have White insulation label affixed.
NOTE: If insulating label is not affixed to terminal screw marked "WH", use electrical tape to cover.
•Proceed to Step 5.