Lewmar 34-77 Electrical wiring installation, Typical electrical layout, Main spindle rotation

Models: 34-77

1 22
Download 22 pages 4.75 Kb
Page 8
Image 8

2. Electrical wiring installation

GB

Fig. 2.1.1

3

 

2

4

1

5

System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cross

 

 

 

 

Cable

 

 

 

 

 

 

 

Distance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

sectional

 

 

 

 

size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power supply to winch

 

 

 

(V)

 

 

 

 

 

 

 

 

 

area

 

 

 

 

 

(US Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

Up to 10 m (33 ft)

 

 

 

 

 

50 mm

 

2

 

 

1/Ø

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

10 to 15 m (33 to 49 ft)

 

 

 

70 mm

 

2

 

 

2/Ø

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

15 to 20 m (49 to 66 ft)

 

 

 

95 mm

 

2

 

 

3/Ø

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

24

 

 

 

 

 

Up to 7 m (23 ft)

 

 

25 mm

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 to 10 m (23 to 33 ft)

 

 

 

35 mm

2

 

 

 

 

 

24

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

 

 

 

10 to 13 m (33 to 43 ft)

 

 

 

50 mm

 

2

 

 

1/Ø

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery size

Up to 300

Amp/hrs

2.1 Typical electrical layout

NOTE: This is not a wiring diagram.

1.Position the recommended circuit breaker close to the battery. See wiring diagrams Sec. 3.

2.Route 2 cables (see size table above) from battery to the control box.

3.Attach motor cables to control box (see wiring diagram) using recommended cable sizes.

4.Position the control box near the winch (±1 metre) in a dry area for watertight security and accessible for maintenance.

5.Position deck switches in view of winch. Route wire and attach to control box (see wiring diagram).

2.2 Main spindle rotation

Check correct main spindle rotation when fitted and operated.

Fig. 2.2.1

Winch

 

1st Gear

 

2nd Gear

 

3rd Gear

2Speed 66−77

3Speed 66−77

Ocean Electric Winches 34 - 77

9

Page 8
Image 8
Lewmar 34-77 Electrical wiring installation, Typical electrical layout, Main spindle rotation, Battery size, Up to Amp/hrs