4.2. EYE-Q function check

4.2. EYE-Q function check

Step 1) Turn on the TV set.

Step 2) Press “EYE” key on Adjustment remote control.

Step 3) Cover the Eye Q sensor at the front of set for 6 seconds. Step 4) Check the value of Sensor Data. It must be below 10.

If not so, the Eye Q sensor may have some defect. Change the Eye Q sensor.

Step 5) Wait for 6 seconds after withdrawing form the Eye Q sensor.

Step 6) Check the value of Backlight. It must rise.

If not so, the Eye Q sensor may have some defect. Change the Eye Q sensor.

<Step 2>

 

<Step 3>

<Step 4>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Step 5>

<Step 6>

* EYE-Q Test is except for LV23xx/LK33x/LK43x series.

4.3. Outgoing condition Configuration

-When pressing IN-STOP key by Service remote control, Red LED are blinked alternatively. And then automatically turn off. (Must not AC power OFF during blinking)

5.GND and HI-POT Test

5.1. GND & HI-POT auto-check preparation

Check the Power cable and Signal cable insertion condition

5.2.GND & HI-POT auto-check

(1)Pallet moves in the station. (Power cord / AV cord is tightly inserted)

(2)Connect the AV JACK Tester.

(3)Controller (GWS103-4) on.

(4)GND Test (Auto)

-If Test is failed, Buzzer operates.

-If Test is passed, execute next process (Hi-pot test). (Remove A/V CORD from A/V JACK BOX.)

(5)HI-POT test (Auto)

-If Test is failed, Buzzer operates.

-If Test is passed, GOOD Lamp on and move to next process automatically.

5.3.Checkpoint

(1)Test voltage

-GND: 1.5 KV / min at 100 mA

-SIGNAL: 3 KV / min at 100 mA

(2)TEST time: 1 second

(3)TEST POINT

-GND Test = Power cord GND and Signal cord GND.

-Hi-pot Test = Power cord GND and LIVE & NEUTRAL.

(4)LEAKAGE CURRENT: At 0.5 mArms

6.Model name & Serial number D/L

Press “Power on” key of service remote control. (Baud rate : 115200 bps)

Connect RS232 Signal Cable to RS-232 Jack.

Write Serial number by use RS-232.

Must check the serial number at the Diagnostics of SET UP menu(Refer to below.)

6.1. Signal TABLE

CMD

LENGTH

ADH

ADL

DATA_1

. . .

Data_n

CS

DELAY

CMD : A0h

LENGTH : 85~94h (1~16 bytes)

ADH : EEPROM Sub Address high (00~1F)

ADL : EEPROM Sub Address low (00~FF)

Data : Write data

CS : CMD + LENGTH + ADH + ADL + Data_1 +…+ Data_n

Delay : 20ms

6.2. Command Set

No.

Adjust mode

CMD(hex)

LENGTH(hex)

Description

 

 

 

 

 

1

EEPROM WRITE

A0h

84h+n

n-bytes Write(n=1~16)

 

 

 

 

 

*Description

FOS Default write : <7mode data> write

Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0, Phase

Data write: Model name and Serial number write in EEPROM,.

6.3. Method & notice

A. Serial number D/L is using of scan equipment.

B. Setting of scan equipment operated by Manufacturing Technology Group.

C. Serial number D/L must be conformed when it is produced in production line, because serial number D/L is mandatory by D-book 4.0.

Copyright ©2012 LG Electronics. Inc. All right reserved.

- 12 -

LGE Internal Use Only

Only for training and service purposes

 

 

Page 12
Image 12
LG Electronics 42CS669C-ZD GND and HI-POT Test, Model name & Serial number D/L, EYE-Q function check, Checkpoint