109
ENGENGLISH
EXTERNAL CONTROL DEVICE SETUP
Command reference listCommunication Parameters

yBaud rate: 9600 bps (UART)

yData length: 8 bits

yParity : None

yStop bit: 1 bit

yCommunication code: ASCII code

yUse a crossed (reverse) cable.

y* Note : During USB operations such as DivX or EMF, all commands except Power(ka) and Key(mc)

are not executed and treated as NG.

COMMAND1 COMMAND2
DATA
(Hexadeci-
mal)
COMMAND1 COMMAND2
DATA
(Hexadeci-
mal)
01. Power k a 00 to 01 14. Bass k s 00 to 64
02. Aspect
Ratio k c (See p.111) 15. Balance k t 00 to 64
03. Screen
Mute k d (See p.111) 16. Colour
Temperature x u 00 to 64
04. Volume
Mute k e 00 to 01 17. ISM
Method j p (See p.113)
05. Volume
Control k f 00 to 64 18. Energy
Saving j q 00 to 05
06. Contrast k g 00 to 64 19. Auto Con-
figuration j u 01
07. Brightness k h 00 to 64 20. Tune Com-
mand m a (See p.113)
08. Colour k i 00 to 64 21. Programme
Add/Skip
m b 00 to 01
09. Tint k j 00 to 64 22. Key m c Key Code
10. Sharpness k k 00 to 64 23. Control
Back Light
m g 00 to 64
11. OSD Select k l 00 to 01 24. Input select
(Main)
x b (See p.114)
12. Remote
Control
Lock Mode
k m 00 to 01
25. 3D x t (See p.114)
13. Treble k r 00 to 64 26. Extended
3D
x v (See p.114)
Downloaded From TV-Manual.com Manuals