Owner's Manual
11
16 AUTO CLEAN
Used to set Auto Clean mode.
17 ˚C TO ˚F SWITCHING BUTTON
Used to switch temperature reading from Centigrade to Fahrenheit.
18 HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON (NOT ON ALL MODELS)
Used to set the desired horizontal airflow direction.
START/STOP BUTTON
Operation starts when this button is pressed and stops when the button is pressed again.
OPERATION MODE SELECTION BUTTON Used to select the operation mode.

Operating Instructions

RemoteControlOperation

The Remote Controller transmits the signals to the system.

1

Signal transmitter

2

 

 

3

ROOM TEMPERATURE

(Heat Pump) (Cooling Only)

 

 

 

 

 

SETTING BUTTONS

 

 

 

 

 

 

 

 

Used to select the room temperature.

 

 

 

4

INDOOR FAN SPEED SELECTOR

 

 

 

 

Used to select fan speed in four steps

 

 

 

 

low, medium, high and CHAOS.

 

5

1

5

JET COOL

 

6

 

 

 

Used to start or stop the speed cooling/heating.

 

3

 

(Speed cooling/heating operates super high fan

 

 

speed.)

 

4

 

 

 

6

CHAOS SWING BUTTON

 

 

10

Used to stop or start louver movement and set

2

 

 

 

 

 

 

the desired up/down airflow direction.

 

CANCEL

 

 

7

 

9

 

 

OFF

SET

7

ON/OFF TIMER BUTTONS

ON

16

 

11

 

AUTO CLEAN

Used to set the time of starting and stopping operation.

 

 

 

 

 

8

 

° C/° F

12

8

TIME SETTING BUTTONS

13

 

17

Used to adjust the time.

 

 

 

 

 

 

 

 

18

9

TIMER SET/CANCEL BUTTON

14

 

 

Used to set the timer when the desired time is obtained and

 

 

15

 

 

 

 

to cancel the Timer operation.

 

 

 

 

 

 

 

 

 

10

SLEEP MODE AUTO BUTTON

 

 

 

 

 

Used to set Sleep Mode Auto operation.

Flip-up door

11

AIR CIRCULATION BUTTON

(opened)

 

Used to circulate the room air without cooling or heating.

Operation Mode

12

ROOM TEMPERATURE CHECKING BUTTON

 

 

Used to check the room temperature.

Cooling Operation

13

PLASMA(OPTIONAL)

Used to start or stop the plasma-purification function.

 

Auto Operation

14

RESET BUTTON

 

 

Initialize remote controller.

Healthy Dehumidification Operation

15

2nd F Button

 

 

Used prior to using modes printed in blue at the bottom of

buttons.

Heating Operation

• Cooling Model(), Heat Pump Model( )

ENGLISH

Page 11
Image 11
LG Electronics EN 61000-3 NORM Remote Control Operation, Signal transmitter, Cooling Model , Heat Pump Model

EN 61000-3, EN 61000-3 NORM specifications

LG Electronics has consistently been at the forefront of technological innovation, and its commitment to compliance with international standards is evident in its adherence to EN 61000-3 norms. The EN 61000-3 series focuses on electromagnetic compatibility (EMC) concerning emissions and immunity, particularly in residential, commercial, and light-industrial environments. This standard is critical for ensuring that electronic devices do not generate excessive electromagnetic interference (EMI), while also ensuring their proper functioning in the presence of such interference from other devices.

One of the main features of the EN 61000-3 standard is the regulation of harmonic emissions. Devices must limit the levels of harmonic currents they introduce into the power system. This requirement is crucial for maintaining the integrity of electrical networks and preventing issues that could arise from harmonics such as overheating and equipment failures. LG Electronics ensures that its products, including appliances and electronic devices, are designed to stay within the specified limits of the norm, thereby promoting energy efficiency and longevity.

Another characteristic of the EN 61000-3 standard is its focus on voltage fluctuations and flicker. Voltage fluctuations can lead to flickering lights and other undesirable effects. By adhering to these requirements, LG Electronics demonstrates its dedication to providing products that enhance user experience and reduce discomfort. This is especially critical in environments where stable power supply is essential, such as in home theaters or professional audio setups.

In terms of technologies, LG incorporates advanced filtering techniques and power management systems in its devices to ensure compliance with the EN 61000-3 norms. These technologies help mitigate EMI and ensure that the devices operate effectively in varied electrical environments. Furthermore, LG's commitment to research and development allows the company to innovate continuously, ensuring that its future products will not only comply with current standards but also embrace ongoing changes in global regulations.

In conclusion, LG Electronics' adherence to the EN 61000-3 norms underscores its commitment to producing high-quality, reliable, and efficient electronic devices. By prioritizing harmonics control and mitigating voltage fluctuations, LG not only enhances user experience but also contributes to a sustainable future. Through ongoing technological advancements and compliance with stringent international standards, LG reinforces its position as a leader in the electronics industry.