PRECAUTIONS
Note: These fireplace systems are not difficult to install. However, in the interest of safety, it is recommended that the installer be a qualified or certified “tradesman” familiar with commonly accepted fireplace installation and safety techniques as well as prevailing local codes.
The most important areas of concern dealing with the installation of
TYPICAL INSTALLATION
Chimney and
Termination
Model LS43ST
Figure 1
INTRODUCTION
General Information
This Signature Series LS43ST is a radiant- heat,
Note: Illustrations shown reflect “typical” installations with nominal dimensions and are for design and framing reference only. Actual installations may vary due to individual design prefer- ences.However,alwaysmaintainminimumclearances to combustible materials and do not violate any specific installation requirements.
These fireplaces have been tested and listed by
These fireplace systems are designed for installation in accordance with the National Fire Protection Standard for chimneys, fireplaces and solid fuel burning appliances; NFPA 211 and in accordance with codes such as the BOCA Basic/National Codes, the Standard Mechanical Code and the Uniform Building Codes.
The local authority having jurisdiction should be consulted before installation, to determine if any permits need to be obtained.
WARNING: FAILURE TO USE MANUFACTURE PROVIDED PARTS, VARIATIONS IN TECHNIQUES AND CONSTRUCTION MATERIALS OR PRACTICES OTHER THAN THOSE DESCRIBED IN THIS MANUAL MAY CREATE A FIRE HAZARD AND VOID THE LIMITED WARRANTY.
The LS43ST system consists of three “sub- systems”:
1.The Fireplace and Door Assemblies
2.The Chimney and Termination
3.The Optional Combustion Air Kit
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
CLEARANCES AND HEIGHT
REQUIREMENTS
The fireplace may be placed on or near normal construction materials*. The combustion air kit, firestop spacer and roof flashing (not chase flashings) may be placed directly on or against normal construction materials.* The chimney and fireplace outer wrapper require a minimum 2" and 1" air space to combustibles respectively. A combustible mantle may be installed 12" above the opening of the fireplace as per NFPA 211, Section
The fireplace opening of the LS43ST must be kept a minimum of 12" (305 mm) from a side wall. A perpendicular side wall can not be closer that 12" (305 mm) to the LS43ST fireplace.
As with all chimney installations, avoid overhead obstructions such as trees, power lines, etc. Additionally chimney terminations must meet certain clearance to roof requirements detailed in the paragraph titled
The fireplace and chimney system must be enclosed when installed in or passing through a living area where combustibles or people may come in contact with it. This is important to prevent possible personal injury or fire hazard.
For questions, please call your distributor or the manufacturer. Special restrictions apply to the front and facing of the fireplace and nearby walls (See pages 18, 19 and 20 ).
*Construction Materials: |
|
• framing materials | • paneling |
• particle board | • flooring |
• dry wall | • etc. |
• plywood |
|
3