LG Electronics LT1010CR, LT1210CR, LT0810CR owner manual To achieve rearward slope for unit draining

Models: LT0810CR LT1210CR LT1010CR

1 48
Download 48 pages 47.15 Kb
Page 17
Image 17

Installation

PROCEDURE C

7

To achieve rearward slope for unit draining,

remove the backing from the 1113/16" shim

 

 

strips and attach them as shown below in Fig.

 

21. The higher portion of shim is to be placed

 

in front of the rib on the base of wall sleeve.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1" high

 

 

 

 

 

 

3/4" High

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIG. 20

 

 

 

 

 

 

 

 

 

 

 

Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit.

To prevent injury or strain, use proper lifting and carrying techniques when moving unit.

When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.

Make sure air conditioner does not fall during removal.

If unit does not operate after installation check, to be sure the circuit interrupter has not been tripped. Refer to the Troubleshooting guide for reset procedure.

ENGLISH

6"

Shim (2EA)

6"

FIG. 21

8 Install the new unit into the wall sleeve

9 Assemble trim as described in Step 6, Procedure A.

Owner’s Manual 17

Page 17
Image 17
LG Electronics LT1010CR, LT1210CR To achieve rearward slope for unit draining, Remove the backing from the 1113/16 shim