—3—
1. PREFACE
This service manual provides various service information, including the mechanical and electrical parts, etc.
This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory.Be sure to read the safety precautions prior to servicing the unit.

1.1 FEATURES

DESIGNED FOR COOLING ONLY
POWERFUL AND INCREDIBLE COOLING
TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE
BUILT-IN ADJUSTABLETHERMOSTAT
WASHABLE ONE-TOUCHFILTER
COMPACTSIZE

1.2 SPECIFICATIONS

• NOTE: Specifications are subject to minor change without notice for further improvement.
MODELS
ITEMS
COOLING CAPACITY(BTU/h) 5,000
POWER SUPPLY(Phase, V, Hz) 1Ø, 220-240V,50HZ
INPUT (W) 625
OPERATINGCURRENT (AMP.) 2.8
REFRIGERANT CONTROL CAPILLARY TUBE
REFRIGERANT CHARGE (R-22) 200g
INSIDE FAN TURBO
OUTSIDE FAN PROPELLERFAN WITH SLINGER RING
AIR DISCHARGE 2-WAY(RIGHT AND LEFT)
CHASSIS TOP-DOWN
PROTECTOR
TEMPERATURECONTROL THERMOSTAT
ROTARY SWITCH 5 STEP (LOW FAN,HIGH FAN, OFF, HIGH COOL, LOWCOOL)
FANMOTOR 4 POLES, 18W
• OVERLOAD PROTECTORFOR COMPRESSOR
• INTERNAL PROTECTORFOR FAN MOTOR
LWJ0561ACG,LWJ0561ACP/AAG