4.6. 3D function test

4.6. 3D function test

(Pattern Generator MSHG-600, MSPG-6100[Support HDMI1.4]) * HDMI mode NO. 872 , pattern No.83

(1)Please input 3D test pattern like below.

(2)When 3D OSD appear automatically, then select OK key.

Step 4) If the system finds any AP like blow PIC, it is working well.

(3)Don't wear a 3D Glasses, check the picture like below.

4.7.Wi-Fi Test

Step 1) Turn on TV

Step 2) Select Network Connection option in Network Menu.

Step 3) Select Start Connection button in Network Connection.

4.8. LNB voltage and 22KHz tone check

(only for DVB-S/S2 model)

Test method

(1)Set TV in Adj. mode using POWER ON.

(2)Connect cable between satellite ANT and test JIG.

(3)Press Yellow key(ETC+SWAP) in Adj Remote control to make LNB on.

(4)Check LED light ‘ON’ at 18 V menu.

(5)Check LED light ‘ON’ at 22 KHz tone menu.

(6)Press Blue key(ETC+PIP INPUT) in Adj Remote control to make LNB off.

(7)Check LED light ‘OFF’ at 18 V menu.

(8)Check LED light ‘OFF’ at 22 KHz tone menu.

Test result

(1)After press LNB On key, ‘18 V LED’ and ‘22 KHz tone LED’ should be ON.

(2)After press LNB OFF key, ‘18 V LED’ and ‘22 KHz tone LED’ should be OFF.

4.9. Option selection per country

4.9.1. Overview

- Option selection is only done for models in Non-EU

4.9.2. Method

(1)Press ADJ key on the Adj. R/C, then select Country Group Meun

(2)Depending on destination, select Country Group Code 04 or Country Group EU then on the lower Country option, select US, CA, MX. Selection is done using +, - or ►◄ key.

4.10. Tool Option selection

Method : Press "ADJ" key on the Adjustment remote control, then select Tool option.

4.11. Ship-out mode check(In-stop)

After final inspection, press "IN-STOP" key of the Adjustment remote control and check that the unit goes to Stand-by mode.

Copyright ©

LG Electronics. Inc. All rights reserved.

- 16 -

LGE Internal Use Only

Only for training and service purposes

 

 

Page 16