Framing Ceiling

Frame the opening for the ceiling as speci- ficed here.

B

Note: Faming Dimensions in Canada & USA are different

because installations in USA require 1" Clearance to pipe.A Installations in Canada require 2" Clearance to pipe.

Ceiling Framing

Framing Dimensions for Ceiling

Inches (millimeters)

Flue Type

A

B

 

 

 

FTF8 Vertical

14 1/2"

14 1/2"

(USA)

(368 mm)

(368 mm)

 

 

 

FTF8 Vertical at 2"

16 1/2"

16 1/2"

(Canada)

(419 mm)

(419 mm)

FTF8 Offset 30°

14 1/2"

25"

(USA)

(368 mm)

(635 mm)

 

 

 

FTF8 Offset 30° at 2"

16 1/2"

27"

(Canada)

(419 mm)

(686 mm)

Figure 19

INSTALLING THE FIREPLACE

Step 1. Slide the fireplace into prepared framing or position fireplace in its final position and frame later.

The fireplace may not be recessed into a combustible floor. Maintain the floor to hearth clearance established by the fireplace lower front face.

Step 2. Insert the provided metal safety strips, beneath the fireplace as illustrated (Figures 21, 22 & 23). The safety strips should overlap 1/2 min. for continual coverage of the floor.

Note: Safety strips are not required when fire- place rests on a noncombustible surface.

Top Spacer

Maintain 1" (25 mm) Air Space At Back And Sides

1" (25 mm) Space

Hearth Extension

Framing Roof

Frame the opening for the roof as specificed here.

 

Note: Faming Dimensions in Canada & USA are different

 

C

 

because installations in USA require 1" Clearance to pipe.

D

 

 

 

Installations in Canada require 2" Clearance to pipe.

 

 

Roof Framing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Framing Dimensions for Roof

 

 

 

 

 

 

Inches (millimeters)

 

 

 

 

 

 

 

 

 

 

 

 

Pitch

FTF8 at 1" (USA)

FTF8 at 2" (Canada)

 

 

 

 

 

 

 

 

 

 

 

C

 

D*

C

D*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0/12

14 1/2"

 

14 1/2"

16 1/2"

16 1/2"

 

 

 

 

(368 mm)

 

(368 mm)

(419 mm)

(419 mm)

 

 

 

6/12

14 1/2"

 

17"

16 1/2"

19"

 

 

 

 

(368 mm)

 

(442 mm)

(419 mm)

(483 mm)

 

 

 

12/12

14 1/2"

 

21 1/2"

16 1/2"

23 1/2"

 

 

 

 

(368 mm)

 

(546 mm)

(419 mm)

(579 mm)

 

 

 

* Perpendicular to roof ridge

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 20

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Metal Safety Strip

Floor

Note: Hearth extensions must not interfere with circulating grillwork

Figure 21

Maintain 1" (25 mm) Air Space At Back And Sides

Hearth

Extension 1" (25 mm) Space

Metal Safety Strip

Platform

Floor

Note: Hearth extensions must not interfere with circulating grillwork

Figure 22