Offset Elevation Chart

A

 

B

 

FTF8-ES30

 

Number of FTF8 Chimney Sections

Offset

Height

Offset/Return

FTF8-S4

 

 

 

 

 

 

 

 

(Inches)

(Inches)

Elbow

Stabilizer

12"

18"

36"

48"

 

 

 

 

 

 

 

 

 

 

4

 

15

³⁄₄

1

0

0

0

0

0

9

 

24

¹⁄₂

1

0

1

0

0

0

12

 

29

³⁄₄

1

0

0

1

0

0

14

¹⁄₄

33

¹⁄₂

1

0

2

0

0

0

 

 

 

 

 

 

 

 

 

 

17

¹⁄₄

38

¹⁄₂

1

0

1

1

0

0

20

¹⁄₄

43

³⁄₄

1

0

0

2

0

0

21

 

45

¹⁄₄

1

0

0

0

1

0

22

¹⁄₄

47

¹⁄₂

1

0

2

1

0

0

 

 

 

 

 

 

 

 

 

 

25

¹⁄₄

52

¹⁄₂

1

0

1

2

0

0

26

¹⁄₄

54

¹⁄₄

1

0

1

0

1

0

27

 

55

³⁄₄

1

0

0

0

0

1

28

¹⁄₄

57

³⁄₄

1

0

0

3

0

0

29

¹⁄₄

59

¹⁄₄

1

0

0

1

1

0

31

¹⁄₄

63

 

1

0

2

0

1

0

32

¹⁄₄

64

¹⁄₂

1

0

1

0

0

1

34

¹⁄₄

68

¹⁄₄

1

0

1

1

1

0

35

¹⁄₄

69

³⁄₄

1

0

0

1

0

1

37

¹⁄₄

73

¹⁄₄

1

0

0

2

1

0

38

¹⁄₄

75

 

1

0

0

0

2

0

39

¹⁄₄

77

 

1

0

2

1

1

0

41

¹⁄₂

80

¹⁄₂

1

0

1

4

0

0

43

¹⁄₄

83

³⁄₄

1

0

1

0

2

0

44

¹⁄₄

85

¹⁄₄

1

0

0

0

1

1

45

¹⁄₄

87

¹⁄₂

1

0

0

3

1

0

 

 

 

 

 

 

 

 

 

 

46

¹⁄₄

89

 

1

0

0

1

2

0

48

¹⁄₄

91

¹⁄₂

1

0

2

0

2

0

49

¹⁄₄

94

¹⁄₄

1

0

1

0

1

1

50

¹⁄₄

95

³⁄₄

1

0

0

0

0

2

51

¹⁄₄

97

³⁄₄

1

0

1

1

2

0

54

¹⁄₄

103

 

1

0

0

2

2

0

55

¹⁄₄

104

¹⁄₂

1

0

1

0

0

2

56

¹⁄₂

106

¹⁄₂

1

0

2

1

2

0

58

¹⁄₄

109

³⁄₄

1

0

0

1

0

2

61

³⁄₄

116

 

1

1

1

0

3

0

64

³⁄₄

121

¹⁄₄

1

1

0

1

3

0

67

 

124

³⁄₄

1

1

2

0

3

0

 

 

 

 

 

 

 

 

 

 

68

³⁄₄

128

 

1

1

0

0

1

2

70

 

130

 

1

1

1

1

3

0

73

 

135

¹⁄₄

1

1

0

2

3

0

74

³⁄₄

138

¹⁄₄

1

1

0

0

0

3

79

 

145

¹⁄₂

1

1

1

0

4

0

80

 

147

¹⁄₄

1

1

1

0

0

3

82

 

150

³⁄₄

1

1

0

1

4

0

82

¹⁄₄

152

 

1

1

0

1

0

3

 

 

 

 

 

 

 

 

 

 

Table 4

18

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Return

Elbow

Figure 50

Note: The return elbow assembly performs the same function as a stabilizer. Consider this when determining the need for a stabilizer.

Note: Do not apply excessive pressure to any subsequent chimney section following return elbow assembly when installing. Ensure that each subsequent chimney section is securely attached by testing as noted above.

Gas Line Connection

Install a 1/2" gas supply line through fireplace wall for connection to a decorative gas appliance inside the firebox. Outside, the gas supply line connects to a gas shut-off valve recessed flush into the wall or floor. The valve should be controlled by a removable valve key for safety.

Always plumb gas line installation per local codes. Check all connections with a gas leak detection solution for leaks (which will bubble if present). Never test any gas line connection with a match or open flame.

This provision is intended for connection to a decorative gas appliance incorporating an automatic shut-off device and complying with the Standard for Decorative Gas Appliances for installation in vented fireplaces, ANSI Z21.60 (1991) or American Gas Association draft requirements for Gas-Fired Log Lighters for Wood Burning Fireplaces, Draft No. 4 dated August, 1993. Install in accordance with the National Fuel Gas Code, ANSI Z223.1. This complies with the revised U.L. 127 standard.