2
SAFETY INSTRUCTIONS................................................................................................................................... 3
GLOSSARY OF SYMBOLS.................................................................................................................................3
INTRODUCTION................................................................................................................................................. 4
UPS SUPPORT................................................................................................................................................5
INSTALLATION...................................................................................................................................................5
UNLOADING AND INSPECTION..................................................................................................................... 5
LOCATION.......................................................................................................................................................5
INSTALLATION CONNECTIONS..................................................................................................................... 6
INSTALLING CUSTOMER EQUIPMENT..........................................................................................................6
START-UP....................................................................................................................................................... 7
OPERATION....................................................................................................................................................... 8
ENVIRONMENTAL CONTROL MODULE (ECM) & UNINTERRUPTIBLE AIR SUPPLY™ (UAS)......................8
FORCED AIR COOLING (FAC)........................................................................................................................8
SITENET® INTEGRATOR®.............................................................................................................................8
SENSOR OPTIONS......................................................................................................................................... 9
MAINTENANCE................................................................................................................................................ 10
FILTER CLEANING........................................................................................................................................10
ECM REPLACEMENT....................................................................................................................................10
UPS REPLACEMENT.................................................................................................................................... 10
TABLES............................................................................................................................................................ 11
FORCED AIR COOLING (FAC) PERFORMANCE DATA (WITH 30PPI FILTER)............................................ 11
ENVIRONMENTAL COOLING MODULE (ECM) PERFORMANCE DATA.......................................................11
FIXED SERVICE CONNECTION (AMPS).......................................................................................................12
MAX. AVAILABLE CUSTOMER EQUIPMENT AMPS..................................................................................... 12
FULL LOAD AMP DRAW (230V - 50HZ).........................................................................................................12
DRAWINGS.......................................................................................................................................................13
TROUBLESHOOTING.......................................................................................................................................23
Model Number Breakdown
RD 78 38 MDEK
Enclosure
Rack Width Enclosure
Height/ Depth Main or
Cluster Primary Cooling
System UPS
Rack-Mount Input Power
RD=24" Rack
HD=19" Rack 78" Height
72" Height
38" Depth
34" Depth
(Nominal)
M = Main
C = Cluster A = FAC-190
B = FAC-360
C = ECM-42
D = ECM-62
E = N/A
F = ECM-80
0 = None
A = N/A
B = N/A
C = GXT-1000
D = N/A
E = GXT-1500
F = N/A
G = GXT-2000
K = 120V/60Hz/1PH
S = 230V/50Hz/1PH