16 WTE...6
Information on building in
W Only build the fridge/freezer into units that are firmly fixed
W Make cupboard level using spirit level and set square. If
necessary, even out by placing something underneath. Floor
and side wall of the cupboard must be perpendicular to one
another.
W The ventilation sections must be maintained:
- The depth of the ventilation shaft on the back wall of the cup-
board must be at least 38 mm.
- For the ventilation sections in the plinth of the cupboard and at
the top of the cupboard at least 200 cm2 is required. Basically:
the bigger the ventilation section, the more energy saving the
operation of the appliance.
W Check the dimensions of the appliance and recess for
building in.
W Pull the plastic plug bl out of the door bracket.
Remove the limit stop bm .
Move the limit stop bm to the new hinge side of the door.
Insert the plug bl snugly on the new handle side of the
door. Ensure that the plug is not twisted.
W Attach the handle.
W Remove bearing
bracket 8and angle
bracket 9 (if already
affixed). To do this fold
up the cover of the
angle bracket. Swap
each of the parts to the
opposite side. Screw
on the bearing bracket
8 through the third and sixth slot from the outside.
W Move bearing bracket 5 to the other side and turn through
180°. Fix bearing bracket at the side.
W Move lower bracket pin
7
W Place the door on the
lower bracket pin 7.
W Align the top of the door with
the bearing bracket 5 and
insert upper bracket pin 9.
Installation
W Fasten stop limit 3 through the
white slide element bo with screw
4
W Re-affix covers 1and plugs 2 on the opposite side.