4. (Model 9500HR / 9100) Locate the TELEMETRY CABLE (#17).

Feed the 3-PIN CONNECTOR (3P) end of the cable through the

front of the HANDLEBAR ASSEMBLY (#15). The cable must be

routed down the HANDLEBAR BRACKET TUBE (F) and back up

the top of the MONOCOLUMN (#10). Feed the 3-PIN

CONNECTOR through the DISPLAY CONSOLE MOUNTING

BRACKET (D) ACCESS HOLE.

(Model 9500HR) Locate the HEART RATE CABLE (#18). In

similar fashion, feed the 4-PIN CONNECTOR (4P) end of the cable

through the front of the HANDLEBAR ASSEMBLY (#15). The

cable must be routed down the HANDLEBAR BRACKET TUBE

(F) and back up the top of the MONOCOLUMN (#10). Feed the 4-

PIN CONNECTOR through the DISPLAY CONSOLE MOUNTING

BRACKET (D) ACCESS HOLE. Pull the LEFT HEART RATE

SENSOR CABLE (2PL) (Red/Black) through the LEFT LARGE

HOLE (H) of THE HANDLEBAR BRACKET TUBE. Pull the RIGHT

HEART RATE SENSOR CABLE (2PR) (Green/White) through the

RIGHT LARGE HOLE of THE HANDLEBAR BRACKET TUBE.

5. (Model 8500 / 9100) Align the USER LEFT BULLHORN (#13) to

the HANDLEBAR BRACKET TUBE (F). Using three MOUNTING

SCREWS (#6), secure the USER LEFT BULLHORN to the

HANDLEBAR BRACKET TUBE and the HANDLEBAR (#15).

Tighten the SCREWS securely. Repeat the procedure for the

USER RIGHT BULLHORN (#14).

(Model 9500HR) Locate the USER LEFT BULLHORN (#13) with a

D

3P

15

10

F 17

14 2P

2PR 15

2PL 2P

Lifepulse sensor. Connect the 2-PIN CONNECTOR (2P) leading

from the USER LEFT BULLHORN to the 2-PIN CONNECTOR

(2PL) now leading from the HANDLEBAR BRACKET TUBE (F).

Carefully feed any excess HEART RATE CABLE (#18) into the

HANDLEBAR BRACKET TUBE and secure the USER LEFT

BULLHORN to the HANDLEBAR BRACKET TUBE using three

MOUNTING SCREWS (#6). Tighten the SCREWS securely.

Repeat the procedure for the USER RIGHT BULLHORN (#14) with

a Lifepulse sensor.

6. Locate the POLAR RECEIVER ASSEMBLY (#16). Plug the

POLAR RECEIVER ASSEMBLY into the POLAR RECEIVER

JACK (J). Place the POLAR RECEIVER in a vertical position,

POLAR RECEIVER JACK facing downward, at the front of the

HANDLEBAR BRACKET TUBE (F). Position the POLAR COVER

(#19) over the center of the HANDLEBAR ASSEMBLY (#15) at the

HANDLEBAR BRACKET TUBE. Making sure the POLAR COVER

is oriented properly, slide the POLAR COVER over the

HANDLEBAR ASSEMBLY covering the POLAR RECEIVER

ASSEMBLY and the end of the HANDLEBAR BRACKET TUBE.

The POLAR COVER should fully nest over the HANDLEBAR

ASSEMBLY. Secure the POLAR COVER using two MOUNTING

SCREWS (#8).

CAUTION: DO NOT OVER-TIGHTEN THE PHILLIPS PAN HEAD

SCREWS (#8).

F

10 13

8

J

F8

19

16

15

MISE EN GARDE : NE SERREZ PAS EXCESSIVEMENT LES

VIS CRUCIFORMES À TÊTE CYLINDRIQUE (Nº 8).

Page 6
Image 6
Life Fitness LS8500 manual Mise EN Garde NE Serrez PAS Excessivement LES