LifeSpan TR200 manual Troubleshooting

Models: TR200

1 40
Download 40 pages 19.85 Kb
Page 35
Image 35

TR100 / TR200

Troubleshooting

MyTread

The treadmill is designed and manufactured to be reliable and easy to use. However, if you have a problem, these troubleshooting steps may help you ￿nd the cause.

Problem:

The console is erratic or not lighting up

Solution:

Check to make sure that the treadmill is properly plugged in, turn the power

 

switch o￿ and back on again and make sure the safety key is in place. If the

 

problem persists contact LifeSpan Customer Service.

Problem:

The belt does not stay in the center of the treadmill when in use.

Solution:

First check to make sure that the treadmill is level, then refer to the instructions in

 

this manual on how to tension and adjust the belt.

Problem:

The treadmill motor seems strained or E1 comes up after several minutes of use.

Solution:

The lubricating silicone that is applied to the deck and belt is wearing down and

 

the belt needs to be lubricated with silicone spray.

Problem:

The treadmill belt slips during use.

Solution:

The belt may need to be tensioned after a period of use. Refer to the Belt

 

Tensioning and Adjustment Section of this manual.

Problem:

Speed does not match quick keys. Treadmill Starts at 1 and goes to 16.

Solution:

The treadmill is set up in Metric Mode. See chart on next page for Console

 

Engineering Mode.

Problem:

Heart Rate is erratic or not picking up.

Solution:

Make sure your hands are moist (Aloe Vera helps). Make sure all connectors at the

 

back of the console are properly connected and no wires are damaged.

 

If wearing a chest strap make sure the batteries are good and that the electrodes

 

are moist and position properly on your chest.

Problem:

Treadmill automaticaly pauses during workout.

Solution:

Treadmill is not picking up Step Count. Go into Engineering Mode to turn Intelli

 

Guard o￿.

Problem:

Silicon icon lights up on console.

Solution:

Lubricate the running belt with 100% pure silicone. Then simultaneously press

 

and hold the Speed Down and Start/Stop buttons until the light turns o￿.

Problem:

Maintenance icon lights up on console.

Solution:

This light indicates a scheduled cleaning and maintenance should be done.

 

Please read the Cleaning section in this manual for details. To turn the icon

 

o￿ press the Speed Down and the Start/Stop buttons simultaneously.

35

Page 35
Image 35
LifeSpan TR200 manual Troubleshooting