dual UV lamp operation

dual UV lamp operation (63-1530 only)

1.Press the UV button to turn the Lamps on or off.

2.The Lamps will light and

you will see a faint blue glow along the front of the unit above the grille. “UV” will be displayed in the LCD screen.

NOTE emoving the IFD filter assembly or rning the unit off will cancel the UV Lamp function.

filter clean indicator operation

63-1532 filter clean reminder operation

1.When the filter clean LED illuminates, it is time to inspect/clean the IFD filter (see “removing/cleaning the IFD™ filter”).

2.Once you have cleaned the filter, press the filter reset button until the LED light goes out.

63-1530 filter clean reminder operation

1.As you operate your air purifier, the filter bar within the LCD control panel will slowly fill up with additional bars leading from CLEAN to DIRTY.

2.Once all of the bars are filled in and indicate DIRTY, the LED will illuminate above the control panel. You should inspect/clean the filter

(see “removing /cleaning the IFD™ filter”).

3.Once you have inspected/cleaned the filter, press the filter reset button until the bars decrease to indicate CLEAN. The LED light will now go out.

removing/cleaning the IFD™ filter

to remove the IFD™ filter

1.Turn off and unplug the air purifier.

2. Push the Filter Release

( ) button and then gently lift the filter assembly. The filter assembly will only release if the button is pushed.

3. Remove the pre-filter (see “cleaning the pre- filter”), and set aside.

to clean the IFD™ filter

1.DO NOT USE WATER OR OTHER LIQUIDS TO CLEAN THE IFD FILTER.

2.After removing the IFD Filter assembly from the air purifier, gently tap the filter onto a firm surface within a trash receptacle to release the captured particles. Should the IFD filter(s) dislodge from the frame, just place back in gently.

3.To clean the filter with a vacuum, lay the filter on a flat surface, with the pre-filter side down, and run a vacuum cleaner with a nozzle or brush attachment along the filter to pick-up dirt.

cleaning the pre-filter

to remove the pre-filter

Press the top tab to release the pre-filter from the filter assembly.

to clean the pre-filter

The particle pre-filter helps pick-up large airborne particles that enter the rear grille. This pre-filter can be removed from the frame and rinsed by hand under warm water. Let the pre-filter dry completely before inserting it back into the unit.

installing the filters

NOTE

ease make sure that the air purifier is off and

 

nplugged.

to install the IFD™ filter and pre-filter

1.Insert the lower tab of the pre-filter into the filter assembly and press the top tab into the filter assembly until you hear a “click”.

2.Align the filter assembly with the opening in the unit and insert back into the unit. Press until it is flush and you hear a “click”.

replacing the dual UV lamps

The UV Reset LED light will illuminate when it is time to replace the dual UV bulbs.

to replace the dual UV bulbs (63-1530 only)

1.Be sure to turn off and unplug your air purifier.

2.Press the Filter Release

( ) button and remove the filter

assembly.

3. The UV bulb housing is on the left and has a finger grip for ease of removal. Gently remove the UV bulb housing.

4. Turn the tab towards the unlock symbol ( ).

5.Gently grasp the top of the tab and pull the bulb cartridge straight out of the UV socket. Do not touch the bulb directly with your hands.

6.Do the same for the bottom tab and pull the bulb cartridge out of the UV socket.

7. Replace the top and lower UV bulb sockets.

8.The bulb cartridge will only fit one way; if it does not fit, turn the bulb cartridge the other way (with the arrow

pointing to the center of the unit) and insert.

9.Push down gently so that the bulb cartridge engages with the unit. Turn arrow to the lock position.

10.Discard old UV bulb cartridge(s) only at household hazardous waste collection sites.

11.Place UV bulb housing

back in air purifier housing and then insert IFD™ filter assembly.

12. Press UV reset button.

NOTE ulb and bulb housi are not intended for use ith any other product or purpose.

cleaning and maintenance

to clean the unit

1.Use a clean, dry cloth to wipe the external surfaces of the air purifier. DO NOT USE WATER, GASOLINE, POLISH, OR ANY CHEMICAL SOLUTION.

2.The IFD™ filter and pre-filter should be cleaned at least once a month, or sooner depending on the air quality of the room (see “removing/cleaning the IFD filter” or “cleaning the pre-filter” respectively).

frequently asked questions

How often is cleaning required?

About every four weeks depending on the air quality of the room. Select models have a filter clean indicator, advising you when to clean the filters.

Is the IFD™ Air Purifier considered an ozone generator?

No. Ozone generators produce large amounts of ozone and the EPA considers these unsafe for household use.

replacement filters

If you should damage your pre-filter, order a replacement pre-filter for the LifeWise IFD™ Air Purifier, by visiting our website at www.kaz.com or call us at 1-800-332-1110.

Filter No.

For Model

Qty.

Price

 

 

 

 

63-1533-F

63-1533

1

$6.25 ea.

 

 

 

 

63-1533-F

63-1532

2

$6.25 ea.

 

 

 

 

63-1533-F

63-1530

2

$6.25 ea.

 

 

 

 

consumer relations

Mail questions or comments to:

Kaz, Inc.

Consumer Relations Dept.

250 Turnpike Road Southborough, MA 01772

Call us toll-free at: 1-800-332-1110

E-mail: consumerrelations@kaz.com

Please be sure to specify a model number.

Patent # 6,749,669 and other patents pending.

The ionizing process used by the air purifier produces small amounts of ozone as a by- product. These air purifiers comply with U.S. Government limits for acceptable levels of ozone (less than 50 parts per billion by volume of air circulating through the product). People with a history of respiratory problems or heart/lung disease should consult a physician prior to using this product.

You should first read all instructions before attempting to use this product.

A. This limited 5-year warranty applies to repair or replacement of product found to be defective in material or workmanship within 5 years of the date of purchase. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE. ANY IMPLIED WARRANTY, INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS LIMITED WARRANTY. Some regions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from region to region. This warranty applies only to the original purchaser of this product from the original date of purchase.

B. At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship within the limited warranty period. Defective product should be returned to the place of purchase in accordance with store policy. Thereafter, while within the warranty period defective product may be returned to Kaz.

C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the user’s guide.

D. This warranty DOES NOT cover the pre-filter or the IFD filter except for material or workmanship defects.

E. Return defective product to Kaz, Inc. with a brief description of the problem. Include proof of purchase and a $10 US check or money order for handling, return packing and shipping charges . Please include your name, address and a daytime phone number.

You must prepay shipping charges. Send to:

Kaz, Inc.

Attn: Returns Department 4755 Southpoint Drive Memphis, TN 38118 USA

IFD™ is a trademark of Darwin Technology, Ltd.

©2004. All Rights Reserved. LifeWise™ is a trademark of RadioShack Corporation.

Page 2
Image 2
LifeWise 63-1530, 63-1533, 63-1532 Dual UV lamp operation, filter clean indicator operation, Removing/cleaning the IFD filter