![](/images/new-backgrounds/1009842/98423x1.webp)
dual UV lamp operation
dual UV lamp operation (63-1530 only)
1.Press the UV button to turn the Lamps on or off.
2.The Lamps will light and
you will see a faint blue glow along the front of the unit above the grille. “UV” will be displayed in the LCD screen.
NOTE emoving the IFD filter assembly or rning the unit off will cancel the UV Lamp function.
filter clean indicator operation
63-1532 filter clean reminder operation
1.When the filter clean LED illuminates, it is time to inspect/clean the IFD filter (see “removing/cleaning the IFD™ filter”).
2.Once you have cleaned the filter, press the filter reset button until the LED light goes out.
63-1530 filter clean reminder operation
1.As you operate your air purifier, the filter bar within the LCD control panel will slowly fill up with additional bars leading from CLEAN to DIRTY.
2.Once all of the bars are filled in and indicate DIRTY, the LED will illuminate above the control panel. You should inspect/clean the filter
(see “removing /cleaning the IFD™ filter”).
3.Once you have inspected/cleaned the filter, press the filter reset button until the bars decrease to indicate CLEAN. The LED light will now go out.
removing/cleaning the IFD™ filter
to remove the IFD™ filter
1.Turn off and unplug the air purifier.
2. Push the Filter Release
( ) button and then gently lift the filter assembly. The filter assembly will only release if the button is pushed.
3. Remove the
to clean the IFD™ filter
1.DO NOT USE WATER OR OTHER LIQUIDS TO CLEAN THE IFD FILTER.
2.After removing the IFD Filter assembly from the air purifier, gently tap the filter onto a firm surface within a trash receptacle to release the captured particles. Should the IFD filter(s) dislodge from the frame, just place back in gently.
3.To clean the filter with a vacuum, lay the filter on a flat surface, with the
cleaning the pre-filter
to remove the
Press the top tab to release the
to clean the pre-filter
The particle
installing the filters
NOTE | ease make sure that the air purifier is off and |
| nplugged. |
to install the IFD™ filter and pre-filter
1.Insert the lower tab of the
2.Align the filter assembly with the opening in the unit and insert back into the unit. Press until it is flush and you hear a “click”.
replacing the dual UV lamps
The UV Reset LED light will illuminate when it is time to replace the dual UV bulbs.
to replace the dual UV bulbs (63-1530 only)
1.Be sure to turn off and unplug your air purifier.
2.Press the Filter Release
( ) button and remove the filter
assembly.
3. The UV bulb housing is on the left and has a finger grip for ease of removal. Gently remove the UV bulb housing.
4. Turn the tab towards the unlock symbol ( ).
5.Gently grasp the top of the tab and pull the bulb cartridge straight out of the UV socket. Do not touch the bulb directly with your hands.
6.Do the same for the bottom tab and pull the bulb cartridge out of the UV socket.
7. Replace the top and lower UV bulb sockets.
8.The bulb cartridge will only fit one way; if it does not fit, turn the bulb cartridge the other way (with the arrow
pointing to the center of the unit) and insert.
9.Push down gently so that the bulb cartridge engages with the unit. Turn arrow to the lock position.
10.Discard old UV bulb cartridge(s) only at household hazardous waste collection sites.
11.Place UV bulb housing
back in air purifier housing and then insert IFD™ filter assembly.
12. Press UV reset button.
NOTE ulb and bulb housi are not intended for use ith any other product or purpose.
cleaning and maintenance
to clean the unit
1.Use a clean, dry cloth to wipe the external surfaces of the air purifier. DO NOT USE WATER, GASOLINE, POLISH, OR ANY CHEMICAL SOLUTION.
2.The IFD™ filter and
frequently asked questions
How often is cleaning required?
About every four weeks depending on the air quality of the room. Select models have a filter clean indicator, advising you when to clean the filters.
Is the IFD™ Air Purifier considered an ozone generator?
No. Ozone generators produce large amounts of ozone and the EPA considers these unsafe for household use.
replacement filters
If you should damage your
Filter No. | For Model | Qty. | Price |
|
|
|
|
1 | $6.25 ea. | ||
|
|
|
|
2 | $6.25 ea. | ||
|
|
|
|
2 | $6.25 ea. | ||
|
|
|
|
consumer relations
Mail questions or comments to:
Kaz, Inc.
Consumer Relations Dept.
250 Turnpike Road Southborough, MA 01772
Call us
Please be sure to specify a model number.
Patent # 6,749,669 and other patents pending.
The ionizing process used by the air purifier produces small amounts of ozone as a by- product. These air purifiers comply with U.S. Government limits for acceptable levels of ozone (less than 50 parts per billion by volume of air circulating through the product). People with a history of respiratory problems or heart/lung disease should consult a physician prior to using this product.
You should first read all instructions before attempting to use this product.
A. This limited
B. At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship within the limited warranty period. Defective product should be returned to the place of purchase in accordance with store policy. Thereafter, while within the warranty period defective product may be returned to Kaz.
C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the user’s guide.
D. This warranty DOES NOT cover the
E. Return defective product to Kaz, Inc. with a brief description of the problem. Include proof of purchase and a $10 US check or money order for handling, return packing and shipping charges . Please include your name, address and a daytime phone number.
You must prepay shipping charges. Send to:
Kaz, Inc.
Attn: Returns Department 4755 Southpoint Drive Memphis, TN 38118 USA
IFD™ is a trademark of Darwin Technology, Ltd.
©2004. All Rights Reserved. LifeWise™ is a trademark of RadioShack Corporation.