| 3 3/4 " Aperture Low Voltage MR16 Standard | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| 11 1/8” | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Complete Fixture consists of Reflector Trim &
| Reflector Trims — See Individual Reflector Trim Specification Sheets |
| |||||||
|
|
| Open Downlight |
|
| Adjustable | Enclosed | ||
|
|
|
|
| |||||
| Aperture Cone | Satin Cone |
| Baffles | Slot | Pinhole | Mini Swivel | Eyeball | Wet Location |
2000LV | 2012 | 2008 |
| 2005 | 2006 | 2011 | 2025WH | 2022LV | 2090LV |
| 2012NM | 2008NM |
| 2005WH |
|
|
|
| 2026WH |
| 2013BKNM | 2010 |
| 2005BNM |
|
|
|
|
|
| 2013CD | 2010NM |
| 2005NM |
|
|
|
|
|
| 2013CDNM |
|
|
|
|
|
|
|
|
| 2013NM |
|
|
|
|
|
|
|
|
| 2013BK |
|
|
|
|
|
|
|
|
| 2013WH |
|
|
|
|
|
|
|
|
| 2013 |
|
|
|
|
|
|
|
|
| 2013WD |
|
|
|
|
|
|
|
|
| 2013WDP |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
1.Mounting Frame: .036" (#20 ga.) galvanized steel. Accommodates all ceilings up to 1" thick.
2.Junction Box: 4" x 3 1/2”x 2", .063" (#14 ga.) galvanized steel. U.L. listed for maximum of 8 No. 12 ga. 90° C through branch circuit conductors (75° C end of run). Integral cable clamps permit attachment of nonmetallic Romex® or armored cable without need of additional connectors.
3.Mounting Bars: .059" (#16 ga.) galvanized steel. 13" long bars extend to 27" with integral nailing tabs. Attaches to wood joist without need of accessories.
4.Socket Housing: Aluminum with lamp adjustment assembly allows 35° max. vertical 358° horizontal adjustment. (See reflector trim specification sheet for specific adjustment.)
5.Socket: Field replaceable. Two pin socket,
6.Transformer: Outboard mounted, magnetic, 120V. primary, nominal 12V. secondary. Removable from below.
7.Thermal Protector: Meets NEC and UL requirements. Insulation must be kept 3" away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat.
Dimming
Dimming Controls: use only dimmers specifically designed for use with magnetic transformers, like Lightolier Onset® , Sunrise® series LV or VA dimmers, or any Lightolier Controls dimming system. Low voltage fixtures may produce audible sound when used with dimmers, which may be objectionable in acoustically criti- cal areas.
Options & Accessories
Mounting Bars: | 1964 - 20" set of (2) | |
1956 | - set of (4) | |
Plaster Ceiling Ring: | 1959 | - 7/8" depth for wet plaster ceilings. |
MR16 Socket Replacement: | 1975B | |
277V Remote | 7997 - 277V down to 120V | |
Transformer: |
| 300W max. load. |
Socket for General Electric Turn and Lock (TAL) MR16 Lamp: 1975TAL.
Labels
UL (Suitable for Damp Locations), I.B.E.W.
Romex® is a registered trademark of General Cable Industries Inc.