Lightolier 2001L specifications Page of, Job Information, Type, Lightolier a Genlyte company

Models: 2001L

1 2
Download 2 pages 61.59 Kb
Page 2
Image 2
Type:
18W TRIPLE TUBE LAMP, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH CLEAR LENS

Lytecaster® Performance Recessed CFL Downlighting  2001L

Page of 2

50

60˚

100

150

1

200

30˚

SC = 1.6

CERTIFIED TEST REPORT NO. 3349FR COMPUTED BY LSI PROGRAM **TEST-LITE**

3 ¾" Aperture Vertical Wet Location, Compact Fluorescent, Performance Series, Reflector Trim

CANDLEPOWER SUMMARY

 

ZONAL LUMEN SUMMARY

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

Angle

0˚ CP

 

Zone

Lumens

 

Zone

Lumens

%Lamp

%Fixt

 

Ceiling

 

80%

 

70%

50%

30%

 

0

129

 

 

0-10

13.37

 

0-30

139.25

11.6

38.1

 

Wall

 

70

50

30

10

50

10

50

10

50

10

0

5

135

 

10-20

46.72

 

0-40

232.59

19.4

63.6

 

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

10

150

 

20-30

79.16

 

0-60

353.98

29.5

96.8

 

 

0

36

36

36

36

35

35

34

34

32

32

30

15

165

 

30-40

93.34

 

0-90

365.87

30.5

100

 

 

1

34

33

32

31

32

31

31

30

30

29

27

20

173

 

40-50

79.65

 

90-120

0

0

0

 

Ratio

2

32

30

28

27

29

26

28

27

26

27

24

25

172

 

50-60

41.74

 

90-130

0

0

0

 

3

29

27

25

23

26

23

26

23

25

22

21

30

165

 

60-70

10.17

 

90-150

0

0

0

 

Cavity

4

27

24

22

20

24

20

23

20

22

20

19

35

150

 

70-80

1.58

 

90-180

0

0

0

 

5

25

22

20

18

22

18

21

18

20

17

17

40

131

 

80-90

.14

 

0-180

365.87

30.5

100

 

Room

6

24

20

18

16

20

16

19

16

19

16

15

45

104

 

90

-100

0

 

 

** Efficiency = 30.5%**

7

22

18

16

14

18

14

18

14

17

14

13

50

74

 

100-110

0

 

 

 

 

 

 

 

8

20

17

14

13

17

13

16

13

16

13

12

55

46

 

110-120

0

 

 

 

 

 

 

 

9

19

15

13

12

15

12

15

11

15

11

11

60

24

 

120

-130

0

 

 

 

 

 

 

10

18

14

12

11

14

10

14

10

14

10

10

65

8

 

130-140

0

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

70

3

 

140

-150

0

 

 

 

 

 

 

 

 

 

 

Luminaire Input Watts = 22.0

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

150

-160

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

1

 

160-170

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

0

 

170

-180

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18W TRIPLE TUBE LAMP, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH FRESNEL LENS

50

100

150

200

60˚

1

30˚

SC = 1.4

CERTIFIED TEST REPORT NO. 3348FR COMPUTED BY LSI PROGRAM **TEST-LITE**

CANDLEPOWER SUMMARY

 

ZONAL LUMEN SUMMARY

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

Angle

0˚ CP

 

Zone

Lumens

 

Zone

Lumens

%Lamp

%Fixt

 

Ceiling

 

80%

 

70%

50%

30%

 

0

151

 

 

0-10

14.54

 

0-30

131.6

11

37

 

Wall

 

70

50

30

10

50

10

50

10

50

10

0

5

152

 

10-20

44.62

 

0-40

217.11

18.1

61.1

 

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

10

154

 

20-30

72.45

 

0-60

333.76

27.8

93.9

 

 

0

35

35

35

35

34

34

33

33

31

31

30

15

157

 

30-40

85.51

 

0-90

355.26

29.6

100

 

 

1

33

32

31

30

31

30

29

28

27

27

26

20

159

 

40-50

73.84

 

90-120

0

0

0

 

Ratio

2

31

29

27

26

28

25

27

25

26

24

23

25

158

 

50-60

42.8

 

90-130

0

0

0

 

3

28

26

24

22

25

22

24

22

24

21

20

30

151

 

60-70

16.63

 

90-150

0

0

0

 

Cavity

4

26

23

21

19

23

19

22

19

21

19

18

35

138

 

70-80

4.73

 

90-180

0

0

0

 

5

24

21

19

17

21

17

20

17

20

17

16

40

119

 

80-90

.14

 

0-180

355.26

29.6

100

 

Room

6

23

19

17

15

19

15

18

15

18

15

14

45

97

 

90

-100

0

 

 

** Efficiency = 29.6%**

 

 

7

21

17

15

13

17

13

17

13

16

13

13

50

71

 

100-110

0

 

 

 

 

 

 

 

8

20

16

14

12

16

12

13

15

13

12

11

55

47

 

110-120

0

 

 

 

 

 

 

 

9

18

15

12

11

15

11

14

11

14

11

10

60

28

 

120

-130

0

 

 

 

 

 

 

10

17

14

11

10

13

10

13

10

13

10

9

65

16

 

130-140

0

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

70

9

 

140

-150

0

 

 

 

 

 

 

 

 

 

 

Luminaire Input Watts = 22.0

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

150

-160

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

1

 

160-170

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

0

 

170

-180

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18W TRIPLE TUBE LAMP, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH OPAL LENS

50

100

150

200

60˚

1

30˚

SC = 1.1

CERTIFIED TEST REPORT NO. 3350FR COMPUTED BY LSI PROGRAM **TEST-LITE**

CANDLEPOWER SUMMARY

 

ZONAL LUMEN SUMMARY

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

Angle

0˚ CP

 

Zone

Lumens

 

Zone

Lumens

%Lamp

%Fixt

 

Ceiling

 

80%

 

70%

50%

30%

 

0

151

 

 

0-10

14.23

 

0-30

111.65

9.3

35.8

 

Wall

 

70

50

30

10

50

10

50

10

50

10

0

5

150

 

10-20

39.88

 

0-40

175.81

14.7

56.4

 

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

10

147

 

20-30

57.54

 

0-60

279.09

23.3

89.6

 

 

0

31

31

31

31

30

30

29

29

28

28

26

15

142

 

30-40

64.16

 

0-90

311.48

26

100

 

 

1

29

28

27

26

27

26

26

25

25

24

23

20

134

 

40-50

58.87

 

90-120

0

0

0

 

Ratio

2

27

25

23

22

24

22

23

21

23

21

20

25

125

 

50-60

44.41

 

90-130

0

0

0

 

3

24

22

20

19

22

19

21

18

20

18

17

30

115

 

60-70

25.17

 

90-150

0

0

0

 

Cavity

4

23

20

18

16

20

16

19

16

18

16

15

35

103

 

70-80

7.09

 

90-180

0

0

0

 

5

21

18

16

14

18

14

17

14

17

14

13

40

90

 

80-90

.14

 

0-180

311.48

26

100

 

Room

6

19

6

14

13

16

13

16

12

15

12

12

45

76

 

90

-100

0

 

 

** Efficiency = 26%**

 

 

7

18

15

13

11

15

11

14

11

14

11

11

50

63

 

100-110

0

 

 

 

 

 

 

 

8

17

14

12

10

13

10

13

10

13

10

9

55

50

 

110-120

0

 

 

 

 

 

 

 

9

16

13

11

9

12

9

12

9

12

9

9

60

37

 

120

-130

0

 

 

 

 

 

 

10

15

12

10

8

12

8

11

8

11

8

8

65

25

 

130-140

0

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

70

15

 

140

-150

0

 

 

 

 

 

 

 

 

 

 

Luminaire Input Watts = 22.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

6

 

150

-160

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

1

 

160-170

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

0

 

170

-180

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Job Information

Type:

 

 

Lightolier a Genlyte company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2007 Genlyte Group LLC • C1007

Page 2
Image 2
Lightolier 2001L specifications Page of, Job Information, Type, Lightolier a Genlyte company, Genlyte Group LLC C1007