DISTANCE TO SIDE OF UNIT
6" 12" 18" 24" 30" 36" 42" 48"
0 11.0 6.5 5.5 3.0 2.0 1.5 1.0 0.5 0.5 19.5 16.5 19.5 15.0 10.5 15.0
1 70.0 65.0 34.0 12.0 5.5 8.0 1.5 1.0 1.0 97.0109.5 97.0 80.0 48.5 80.0
2 115.0 110.0 66.0 26.0 9.0 3.5 2.0 1.0 1.0 171.0190.5 171.0 129.0 95.0 129.0
2.5 140.0 130.0 80.0 36.0 14.0 4.5 2.5 1.5 1.0 217.0231.0 217.0 160.0 120.0 160.0
3 120.0 115.0 77.0 39.0 16.5 6.0 2.5 1.5 1.5 203.0 217.0 203.0 144.0 120.0 144.0
4 48.0 48.0 40.0 24.0 14.0 7.5 3.0 2.0 1.5 102.0 113.0 102.5 71.0 69.0 71.0
5 17.0 17.0 16.0 11.5 8.5 5.5 3.0 2.0 1.5 46.5 51.0 46.5 33.0 32.5 33.0
6 8.0 7.0 8.0 6.0 5.0 3.5 2.8 2.0 1.5 25.5 27.0 25.5 18.5 18.5 1 8.5
7 4.0 4.0 5.0 3.5 3.0 3.0 2.0 2.0 1.0 15. 0 18.5 15.0 12. 0 1 2.5 12.0
8 2.5 3.0 3.0 2.5 2.5 2.5 2.0 1.5 0.5 11.5 14.0 11.5 9.0 0.0 9.0
10'-0" Ceiling Height Track 40" from Wall*
DISTANCE TO SIDE OF UNIT
12' 24' 36' 48" 60' 72" 84'
0 6.0 5.0 2.5 2.5 2.0 1.0 0.5 0.0 12.0 9.5 12.0 7.5 6.0 7.5
1 13.0 11.0 9.0 3.5 2-0 1.0 0.5 0.5 21.5 24.0 21.5 17.0 13.5 17.0
2 23.0 18.0 12.0 4.5 3.0 1.0 0.5 0.5 82.5 83.0 82.5 26.0 18.0 26.0
3 25.0 28.0 14.5 5.0 8.0 1.0 0.5 0.5 86.5 40.5 36.5 28.0 21.0 28.0
4 33.0 27.0 15.0 6.0 2.5 1.0 0.5 0.5 48.0 45.0 48.0 36.0 22.5 36.0
4.5 34.0 28.0 16.0 6.0 2.5 1.0 1.0 0.5 48.0 47.0 48.0 37.0 23.5 37.0
5 28.0 25.0 15.0 6.0 2.5 1.5 1.0 0.5 41.0 43.0 41.0 31.5 22.0 81.5
6 20.0 18.0 13.0 5.5 2.0 1.5 1.0 0.5 82.0 34.0 32.0 28.5 20.0 23.5
7 15.0 18.0 9 .0 4.0 1.5 1.5 1.0 1.0 25.0 25.0 25.0 18.0 14.5 18.0
8 10.0 8.5 6.0 3.0 1.5 1.5 1.0 1.0 18.0 18.0 18.0 18.0 10.5 13.0
9 8.0 7.0 4.5 2.0 1.5 1.5 1.0 1.0 14.0 14.0 14.0 11.0 8.5 11.0
10 5.0 4.0 8.5 1.5 1.5 1.5 1.0 1.0 9.0 10.5 9.0 7.5 6.5 7.5
12'-0" Ceiling Height Track 66" from Wall*
DISTANCE TO SIDE OF UNIT
12' 24' 36' 48' 60' 72' 84' 96'
0 3.5 3.0 2.5 2.0 1.0 1.0 0.5 0.5 0.5 5.0 5.0 5.0 4.0 3.0 42
1 5.5 5.0 4.0 3.0 1.5 1.0 0.5 0.5 0.5 7.5 7.5 7.5 6.0 3.5 6.2
2 8.0 7.5 5.5 3.5 2.0 1.5 1.0 0.5 0.5 10.5 10.0 10.5 8.5 5.0 8.8
3 9.0 8.5 7.0 4.5 2.5 1.5 1.0 4.0 0.5 12.0 12.0 12.0 9.5 5.5 9.8
4 10.0 10.0 8.0 5.5 8.0 2.0 1.0 1.0 0.5 18.5 14.5 18.5 10.5 6.5 10.6
5 12.5 12.0 10.0 6.5 3.5 2.0 1.0 1.0 0.5 17.0 17.5 17.0 13.5 8.0 13.4
6 15.0 14.0 11.0 7.5 4.5 2.5 1.5 1.0 1.0 20.0 20.0 20.0 16.5 9.5 16.4
6.5 15.0 14.0 11.0 8.0 4.5 3.0 1.5 1.0 0.5 21.5 20.5 21.5 16.5 10.0 16.4
7 14.0 12.5 10.5 7.5 4.5 8.0 1.5 1.0 0.5 20.0 19.5 20.0 15.0 9.5 15.6
8 12.5 11.5 10.0 7.0 4.0 3.0 1.5 1.5 0.5 18.5 18.0 18.5 13.5 9.0 15.6
9 10.0 9.0 8.0 6.0 4.0 8.0 1.5 1.5 0.5 16.0 15.0 16.0 11.0 8.5 11.2
10 8.5 8.0 7.0 5.0 4.0 3.0 1.5 1.5 0.5 14.0 18.5 14.0 1 9.5 8.5 19.6
11 7.0 6.5 6.0 4.5 8.0 8.0 1.5 1.5 0.5 12.5 11.0 12.5 7.5 7.0 7.6
12 5.5 5.0 4.2 3.0 3.0 2.0 1.5 1.5 0.5 9.5 8.5 9.5 6.0 6.5 6.2

Lighting Data: 150W PAR38 FL

FOOTCANDLES ON WALL: Single Units Multiple Units
EXAMPLE: With track located 40" from wal andmultiple units spaced 38" on center and aimed60° from horizontal, the illumination on wall5' 6" from floor will be 48 f.c. beneath units and47 f.c. between units.38"40"48 f.c.47 f.c.60
°
5'-6"
8'-0" Ceiling Height Track 22" from Wall*
Track Dist.
from Wall
Track Dist.
from Wall
*At recommended track distance from wall forcorresponding ceiling height, wall washer willprovide maximum Illumination at eye level(5' 6' above floor) when aimed 60 from horizontal(I.E.S. recommended practice).Footcandles shown In table for multiple units arebased on a minimum of 5 units when on 18", 27", or38" centers and 8 units when on 57" 62", or 98"centers.Footcandle values are based on average roomconditions.
Track Dist.
from Wall