Lightolier 26046 Power Extention Connector for use with ProSpec, Track System Only, Is, A0197

Models: 26046

1 2
Download 2 pages 31.85 Kb
Page 2
Image 2
Power Extention Connector for use with ProSpec™

INSTRUCTION SHEET NO.

IS:26046

A0197

Page 2 of 2

Power Extention Connector for use with ProSpec

Track System Only.

POWER FEED TO THE CONNECTOR(S) (continued)

DIRECT POWER FEED FROM A STRUCTURAL SURFACE--Fig 4 & Fig. 5

1.Remove the bottom cover (if required) by snapping it out of the connector. Save cover.

2.Push out hole plug.

3.Thread electrical connector into the end cap.

4.Pass conduit or cable through electrical connector and secure conduit or cable to electrical connector.

5.Form the wires to the appropriate screw terminals. Cut and strip wires and attach to the screw terminals. (See wiring section of instruction sheet).

6.Snap the bottom cover onto the connector.

WIRING THE CONNECTOR--Fig. 6 & Fig. 7

Note: Multiple circuits can be fed into the Power Extension Connector. The Connector is not polarized and can be inserted into the track in any orientation. Therefore identification of the circuits during wiring needs to be controlled by the installer or electrician. The brass screw terminals are for the hot leads, the silver screw terminals are for neutral leads, and terminals marked "GND" are for the ground. The individual circuits are arranged vertically (see diagrams).

1.Form the wires to the screw terminals, strip the insulation back 1/2".

2.Slip the wire under the terminal screw head. Tighten all screw terminals when wiring is completed.

3.Make sure stripped portion of wires are not touching each other.

4.Snap bottom cover onto the connector to cover the wires.

There are additional feed in kits (Floating Canopy, End Feed Canopy, Floating Invisible Feed, Grid Ceiling Canopy Kit, Stem Kits....) that can

be used with these connectors. See the Instruction Sheet supplied with the Feed-in Kit for detailed instructions on mounting the kit to the connector.

Power

 

 

 

 

 

Extention

 

 

 

 

 

Connector

 

 

 

 

 

Hole Plug

 

Track Unit

 

Fig. 4

 

 

 

 

Dead End

 

 

 

 

 

 

Power

 

 

 

 

 

Extention

 

 

 

 

End Cap

Connector

 

 

 

 

 

 

 

 

 

Electrical

 

 

 

 

Track Unit

Connector

 

 

 

 

 

(by Others)

 

 

 

 

 

Conduit or Cable

Bottom Cover

 

 

 

 

 

 

(by Others)

 

 

 

 

 

Fig. 5

 

 

 

 

 

Power

 

 

 

er Ou t

Structural

Feed

Mini Coupler or

 

 

Impediment

Power

 

 

w

 

In-Line Connector

o

 

 

P

 

 

 

Feed

 

 

 

 

 

Feed Track

Feed Track

Feed Track

or Power Extension Connector

Power

 

er Ou t

Feed

 

Power

w

o

 

P

 

Feed

 

 

Feed Track

 

 

 

 

 

Use 12 ga. solid copper wire for

 

 

 

feed connections including

Circuit 2

Circuit 1

 

ground.

 

N

N

 

 

 

 

 

 

1

 

Neutral

 

Circuit

2

 

Terminals

Circuit

 

Power

 

 

 

 

Terminals

 

 

 

 

 

 

 

.50

 

 

Fig. 5

 

 

Power

 

 

 

Extension

 

Feed Track

 

Connector

 

 

 

or Power Extension

 

 

 

 

 

 

Connector

Power

 

 

 

Feed

 

 

er Ou t

Power

 

w

 

P

 

 

 

o

 

Feed

 

 

 

Power

 

 

 

Extension

Plain Track

 

 

Connector

Power

 

 

 

Extension

 

Feed Track

 

Connector

 

 

 

or Power Extension

 

 

 

 

 

 

Connector

 

 

Two wires may be

Fig. 6

Ground Terminal

attached to one

screw terminal.

 

Power Extension

Connector

Fig. 7

© 1997

Page 2