Lightolier 37121 Metal Halide T-6Reflector Flood, Metal Halide T-6Narrow Flood, Page 2 of, MHT6RF

Models: 37121

1 2
Download 2 pages 25.86 Kb
Page 2
Image 2
Page 2 of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ProSpec120V/277 Track Lighting  37121

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 2 of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mini HID, Cylinder, 39W T6 CMH (M130)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MHT6RF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Metal Halide T-6 Reflector Flood

Aiming Angle:

L Beam Length

D

Distance

W Beam Width

A

Aiming Angle

C Distance to center beam

FC

Footcandles

L and W are the outer points where the candle power drops to 50% of the maximum. FC are the initial footcandles at the center of the beam.

Lamp data shown is typical. Consult lamp manu- facturers for availability and performance.

CBCP = Center Beam Candle Power.

Flood Reflector

30° Horizontal

30° Vertical

45° Vertical

with 39W T-6 Master Color Ceramic Metal Halide Philips (Clear) Lamp

Lamp

(To 50% CBCP)

 

Life (Hrs.)

 

D

FC

L

W

 

Beam Spread

CBCP

Rated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6'

107

4.4'

4.4'

 

 

 

 

8'

60

5.8'

5.8'

 

 

3,849

9000

10'

38

7.3'

7.3'

39W T-6

 

 

to

12'

27

8.7'

8.7'

 

40°

 

15,000

 

 

 

 

 

D

C

FC

L

W

 

 

 

 

 

6'

3.5'

69

6.1'

5.0'

8'

4.6'

39

8.1'

6.7'

10'

5.8'

25

10.2'

8.4'

12'

6.9'

17

12.2'

10.1'

D

C

FC

L

W

 

 

 

 

 

2'

3.5'

120

9.7'

2.9'

3'

5.2'

53

14.5'

4.4'

4'

6.9'

30

19.3'

5.8'

5'

8.7'

19

24.2'

7.3'

D

C

FC

L

W

 

 

 

 

 

3'

3.0'

151

5.0'

3.1'

4'

4.0'

85

6.7'

4.1'

5'

5.0'

54

8.4'

5.1'

6'

6.0'

38

10.1'

6.2'

MHT6RNF

Metal Halide T-6 Narrow Flood

Aiming Angle:

L Beam Length

D

Distance

W Beam Width

A

Aiming Angle

C Distance to center beam

FC

Footcandles

L and W are the outer points where the candle power drops to 50% of the maximum. FC are the initial footcandles at the center of the beam.

Lamp data shown is typical. Consult lamp manu- facturers for availability and performance.

CBCP = Center Beam Candle Power.

Narrow Flood Reflector

30° Horizontal

30° Vertical

45° Vertical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with 39W T-6 Master Color Ceramic Metal Halide Philips (Clear) Lamp

Lamp

(To 50% CBCP)

 

Life (Hrs.)

 

D

FC

L

W

 

 

Beam Spread

CBCP

Rated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6'

171

3.0'

3.0'

 

 

 

 

 

8'

109

3.7'

3.7'

 

 

 

10,932

12,000

10'

76

4.4'

4.4'

 

 

 

 

 

12'

56

5.2'

5.2'

 

 

21°

 

 

 

 

 

 

 

D

C

FC

L

W

 

 

 

 

 

6'

4.5'

111

4.0'

5.0'

8'

5.8'

71

5.0'

6.7'

10'

6.9'

49

6.0'

8.4'

12'

8.1'

36

7.0'

10.1'

D

C

FC

L

W

 

D

C

FC

L

W

 

 

 

 

 

 

 

 

 

 

 

2'

5.2'

152

5.0'

2.2'

 

5'

5.0'

155

3.8'

2.6'

3'

6.9'

85

6.6'

3.0'

6'

6.0'

107

4.6'

3.1'

4'

8.7'

55

8.3'

3.7'

7'

7.0'

79

5.4'

3.7'

5'

10.4'

38

9.9'

4.4'

8'

8.0'

60

6.1'

4.2'

MHT6RS

Metal Halide T-6 Reflector Spot

Aiming Angle:

L Beam Length

D

Distance

W Beam Width

A

Aiming Angle

C Distance to center beam

FC

Footcandles

L and W are the outer points where the candle power drops to 50% of the maximum. FC are the initial footcandles at the center of the beam.

Lamp data shown is typical. Consult lamp manu- facturers for availability and performance.

CBCP = Center Beam Candle Power.

Spot Reflector

30° Horizontal

30° Vertical

45° Vertical

with 39W T6 Master Color Ceramic Metal Halide Philips (Clear) Lamp

Lamp

(To 50% CBCP)

 

Life (Hrs.)

 

D

FC

L

W

 

Beam Spread

CBCP

Rated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10'

281

1.7'

1.7'

 

 

 

 

15'

125

2.6'

2.6'

 

 

28,105

9,000

20'

70

3.5'

3.5'

39W T6 CMH

10°

 

12,000

25'

45

4.4'

4.4'

 

 

 

 

 

 

 

D

C

FC

L

W

 

 

 

 

 

6'

4.6'

285

1.9'

1.6'

12'

6.9'

127

2.8'

2.4'

16'

9.2'

71

3.7'

3.2'

20'

11.5'

46

4.7'

4.0'

D

C

FC

L

W

 

 

 

 

 

4'

6.9'

220

2.9'

1.4'

6'

10.4'

98

4.3'

2.1'

8'

13.9'

55

5.7'

2.8'

10'

17.3'

35

7.2'

3.5'

D

C

FC

L

W

 

 

 

 

 

6'

6.0'

276

2.1'

1.5'

9'

9.0'

123

3.2'

2.2'

12'

12.0'

69

4.2'

3.0'

15'

15.0'

44

5.3'

3.7'

Job Information

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • A1108

Lightolier is a Philips group brand

Page 2
Image 2
Lightolier 37121 manual Metal Halide T-6Reflector Flood, Metal Halide T-6Narrow Flood, Page 2 of, MHT6RF, MHT6RNF, MHT6RS