Lightolier manual Page 3 of, LightPendant, Architectural Decorative Etched Glass40750UC

Models: 40750UC

1 3
Download 3 pages 37 Kb
Page 3
Image 3
Page 3 of 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Architectural Decorative Etched Glass  40750UC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 3 of 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-Light Pendant

Etched Glass  Catalog No. 40740, 32W CFL Lamp, 2400 Lumens.

180ϒ150ϒ

CANDLEPOWER SUMMARY

ZONAL LUMENS AND PERCENTAGES

COEFFICIENTS OF UTILIZATION

150

120ϒ

100

50

0

90ϒ

60ϒ

0ϒ 30ϒ

Report No. 2692FR

SC = 1.3

ANGLE MEAN CP LMS

089

5

89

8

10

88

 

15

86

24

20

84

 

25

83

38

30

82

 

35

79

49

40

73

 

45

65

51

50

58

 

55

52

47

60

46

 

65

40

40

70

34

 

75

29

33

80

32

 

85

46

52

90

68

 

ANGLE

MEAN CP

LMS

ZONE

LUMENS

% LAMP

%LUMINAIRE

90

68

 

0-30

71

2.96

5.31

95

98

106

0-40

120

5.00

8.97

100

125

 

0-60

217

9.06

16.27

105

148

156

0-90

342

14.27

25.62

110

167

 

40-90

222

9.27

16.64

115

177

175

60-90

125

5.21

9.35

120

184

 

90-180

994

41.45

74.38

125

189

170

0-180

1337

55.72

100.00

130

193

 

 

** Efficiency = 55.7% **

135

194

150

 

140

192

 

 

 

 

 

145186 116

150177

155

168

77

160

152

 

165

130

37

170

109

 

175

87

9

180

76

 

Ceiling

 

 

 

80

 

 

 

70

 

 

 

50

 

 

 

30

 

 

 

10

 

 

 

Wall

 

50

30

10

 

50

30

10

 

50

30

10

 

50

30

10

 

50

30

10

 

0

RCR

 

 

Zonal Cavity

Method - Effective Floor Reflectance = 20%

 

 

 

 

 

0

 

.56

.56

.56

 

.50

.50

.50

 

.39

.39

.39

 

.28

.28

.28

 

.19

.19

.19

 

.14

1

 

.48

.46

.44

 

.43

.41

.39

 

.33

.32

.30

 

.24

.23

.22

 

.16

.15

.15

 

.11

2

 

.42

.38

.35

 

.37

.34

.32

 

.29

.27

.25

 

.21

.19

.18

 

.14

.13

.12

 

.09

3

 

.37

.33

.29

 

.33

.29

.27

 

.25

.23

.21

 

.18

.17

.15

 

.12

.11

.10

 

.07

4

 

.32

.28

.25

 

.29

.25

.22

 

.22

.20

.18

 

.16

.15

.13

 

.11

.10

.09

 

.06

5

 

.28

.24

.21

 

.26

.22

.19

 

.20

.17

.15

 

.15

.13

.11

 

.10

.08

.08

 

.05

6

 

.26

.21

.18

 

.23

.19

.16

 

.18

.15

.13

 

.13

.11

.10

 

.09

.07

.07

 

.05

7

 

.23

.19

.16

 

.20

.17

.14

 

.16

.13

.11

 

.12

.10

.08

 

.08

.07

.06

 

.04

8

 

.21

.16 .14

 

.18 .15

.12

 

.14

.12

.10

 

.11 .09 .07

 

.07

.06

.05

 

.03

9

 

.19 .15 .12

 

.17 .13

.11

 

.13

.10

.09

 

.10 .08 .06

 

.06

.05

.04

 

.03

10

 

.17 .13

.10

 

.15

.12

.09

 

.12

.09

.08

 

.09

.07

.06

 

.06

.05

.04

 

.03

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 31.0

Notes: Multiply calculated footcandle values by .75 for 26W lamp.

Alabaster  Catalog No. 40750, 150W A-21 Lamp, 2780 Lumens.

180ϒ

150ϒ

CANDLEPOWER SUMMARY

ZONAL LUMENS AND PERCENTAGES

COEFFICIENTS OF UTILIZATION

200

150

120ϒ

100

50

0

90ϒ

60ϒ

0ϒ 30ϒ

Report No. 2705FR

SC = 1.3

ANGLE MEAN CP LMS

0140

5

140

13

10

138

 

15

136

38

20

132

 

25

128

59

30

124

 

35

118

74

40

111

 

45

102

79

50

93

 

55

82

74

60

72

 

65

62

62

70

53

 

75

45

49

80

41

 

85

46

53

90

61

 

ANGLE

MEAN CP

LMS

ZONE

LUMENS

% LAMP

%LUMINAIRE

90

61

 

0-30

111

2.00

6.81

95

94

106

0-40

184

3.33

11.34

100

138

 

0-60

337

6.08

20.72

105

179

185

0-90

501

9.02

30.76

110

205

 

40-90

316

5.69

19.41

115

216

213

60-90

163

2.94

10.03

120

223

 

90-180

1129

20.31

69.24

125

228

203

0-180

1630

29.33

100.00

130

229

 

 

** Efficiency = 29.3% **

135

226

174

 

140

219

 

 

 

 

 

145209 131

150194

155

175

80

160

144

 

165

107

31

170

77

 

175

61

6

180

56

 

Ceiling

 

 

80

 

 

70

 

 

50

 

 

30

 

 

10

 

 

Wall

50

30

10

50

30

10

50

30

10

50

30

10

50

30

10

0

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

 

 

 

 

0

.30

.30

.30

.27

.27

.27

.21

.21

.21

.16

.16

.16

.11

.11

.11

.09

1

.26

.25

.23

.23

.22

.21

.18

.18

.17

.14

.13

.13

.10

.09

.09

.07

2

.22

.21

.19

.20

.19

.17

.16

.15

.14

.12

.11

.11

.08

.08

.07

.06

3

.20

.18

.16

.18

.16

.14

.14

.13

.12

.11

.10

.09

.07

.07

.06

.05

4

.17

.15

.13

.16

.14

.12

.12

.11

.10

.09

.08

.08

.07

.06

.05

.04

5

.15

.13

.11

.14

.12

.10

.11

.10

.08

.08

.07

.07

.06

.05

.05

.04

6

.14

.11

.10

.12

.10

.09

.10

.08

.07

.07

.06

.06

.05

.05

.04

.03

7

.12

.10

.08

.11

.09

.08

.09

.07

.06

.07

.06

.05

.05

.04

.03

.03

8

.11

.09 .07

.10 .08

.07

.08

.07

.05

.06 .05 .04

.04

.04

.03

.02

9

.10 .08 .06

.09 .07

.06

.07

.06

.05

.06 .04 .04

.04

.03

.03

.02

10

.09 .07

.06

.08

.06

.05

.07

.05

.04

.05

.04

.03

.04

.03

.02

.02

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 150.0

Etched Glass  Catalog No. 40740, 150W A-21 Lamp, 2780 Lumens.

180ϒ

150ϒ

 

CANDLEPOWER SUMMARY

 

 

ZONAL LUMENS AND PERCENTAGES

200

 

ANGLE MEAN CP

LMS

ANGLE MEAN CP

LMS

ZONE

LUMENS

% LAMP

%LUMINAIRE

 

0

110

 

90

62

 

0-30

 

86

1.55

 

5.40

 

 

 

 

 

 

 

 

5

109

10

95

95

106

0-40

 

143

2.59

 

8.99

150

 

10

108

 

100

138

 

0-60

 

264

4.76

 

16.54

 

120ϒ

15

106

30

105

180

187

0-90

 

405

7.30

 

25.35

100

 

20

102

 

110

209

 

40-90

 

261

4.71

 

16.36

 

 

25

100

46

115

220

217

60-90

 

141

2.54

 

8.81

50

 

30

96

 

120

226

 

90-180

 

1195

21.50

 

74.65

 

35

92

58

125

231

208

0-180

 

1601

28.80

 

100.00

 

 

 

 

0

90ϒ

40

86

 

130

237

 

 

**

Efficiency = 28.8%

**

45

80

62

135

239

184

 

 

 

50

73

 

140

238

 

 

 

 

 

 

 

 

 

55

66

59

145

234

147

 

 

 

 

 

 

 

 

60

58

 

150

227

 

 

 

 

 

 

 

 

 

65

50

50

155

212

96

 

 

 

 

 

 

 

60ϒ

70

43

 

160

183

 

 

 

 

 

 

 

 

75

36

40

165

145

41

 

 

 

 

 

 

30ϒ

 

 

 

 

 

 

80

36

 

170

109

 

 

 

 

 

 

 

Report No. 2706FR

 

 

 

 

 

 

 

 

85

45

51

175

83

8

 

 

 

 

 

 

SC = 1.3

 

 

 

 

 

 

 

 

90

62

 

180

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

 

 

 

 

Ceiling

 

 

 

80

 

 

 

70

 

 

 

50

 

 

 

30

 

 

 

10

 

 

 

Wall

 

50

30

10

 

50

30

10

 

50

30

10

 

50

30

10

 

50

30

10

 

0

RCR

 

 

Zonal Cavity

Method - Effective Floor Reflectance = 20%

 

 

 

 

 

0

 

.29

.29

.29

 

.26

.26

.26

 

.20

.20

.20

 

.15

.15

.15

 

.10

.10

.10

 

.07

1

 

.25

.24

.23

 

.22

.21

.20

 

.17

.16

.16

 

.12

.12

.12

 

.08

.08

.08

 

.06

2

 

.22

.20

.18

 

.19

.18

.16

 

.15

.14

.13

 

.11

.10

.10

 

.07

.07

.06

 

.05

3

 

.19

.17

.15

 

.17

.15

.14

 

.13

.12

.11

 

.10

.09

.08

 

.06

.06

.05

 

.04

4

 

.17

.15

.13

 

.15

.13

.12

 

.12

.10

.09

 

.08

.08

.07

 

.06

.05

.05

 

.03

5

 

.15

.13

.11

 

.13

.11

.10

 

.10

.09

.08

 

.08

.07

.06

 

.05

.04

.04

 

.03

6

 

.13

.11

.09

 

.12

.10

.08

 

.09

.08

.07

 

.07

.06

.05

 

.04

.04

.03

 

.02

7

 

.12

.10

.08

 

.11

.09

.07

 

.08

.07

.06

 

.06

.05

.04

 

.04

.03

.03

 

.02

8

 

.11

.08

.07

 

.10

.08

.06

 

.07

.06

.05

 

.06 .05 .04

 

.04

.03

.03

 

.02

9

 

.10

.08

.06

 

.09

.07

.06

 

.07

.05

.04

 

.05 .04 .03

 

.03

.03

.02

 

.02

10

 

.09

.07

.05

 

.08

.06

.05

 

.06

.05

.04

 

.05

.04

.03

 

.03

.02

.02

 

.01

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 150.0

Job Information

Type:

 

 

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • 0408

Lightolier is a Philips group brand

Page 3
Image 3
Lightolier Page 3 of, LightPendant, Architectural Decorative Etched Glass40750UC, Lightolier is a Philips group brand