SECTION 1A/Folio F50-11 REV. B

 

XT, XR XT2/XR2 SERIES 240/340/440

Page 2 of 2

2'x4' LAY-IN RECESSED FLUORESCENT STATIC, FLAT STEEL LENS FRAME (XT)

 

 

REGRESSED ALUMINUM LENS FRAME (XR), 2, 3, 4 LAMPS, T8 OR T12

PHOTOMETRY

MODEL NO. XT2GVA340120SO coefficients of utilization — zonal cavity method

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

 

1

89

86

83

81

78

76

78

76

74

ratio

2

82

76

72

72

68

65

70

67

64

3

76

68

63

65

60

56

63

59

55

cavity

4

70

61

55

58

53

49

56

52

48

5

64

55

48

52

47

42

51

46

42

room

6

59

49

43

47

41

37

46

41

37

7

55

44

38

43

37

33

41

36

32

 

8

51

40

33

38

33

28

37

32

28

 

9

47

36

29

34

29

25

34

28

24

 

10

43

33

26

31

26

22

31

25

22

visual comfort probability

room size

 

 

 

 

ceiling height

 

 

 

 

ceiling height

 

W

L

 

8.5

10.0

13.0

16.0

 

 

8.5

10.0

13.0

16.0

20

20

 

 

64

68

75

82

 

 

61

65

72

79

20

30

 

 

57

61

66

73

 

 

54

58

63

69

20

40

 

 

54

57

62

66

 

 

49

53

58

62

20

60

 

 

51

54

57

61

 

 

46

49

52

57

30

20

 

 

65

69

74

80

 

 

63

67

72

78

30

30

 

 

58

61

65

70

 

 

55

59

62

68

30

40

 

 

54

57

60

64

 

 

50

53

57

60

30

60

 

 

50

53

55

59

 

 

46

49

51

55

30

80

 

lengthwise

49

51

52

55

 

crosswise

44

46

48

51

40

40

 

55

57

60

63

 

51

54

57

61

40

20

 

 

66

70

75

79

 

 

65

69

73

78

40

30

 

luminaries

59

63

66

70

 

luminaries

57

60

64

68

40

60

 

51

53

55

58

 

47

49

51

54

40

80

 

 

49

51

51

54

 

 

44

47

48

51

40

100

 

 

49

50

50

52

 

 

43

45

45

48

60

30

 

 

60

63

66

70

 

 

58

62

65

69

60

40

 

 

55

58

60

63

 

 

53

56

58

61

60

60

 

 

51

53

55

58

 

 

48

50

51

55

 

 

60

80

 

 

49

51

51

54

 

 

45

47

47

50

60

100

 

 

49

50

49

51

 

 

44

45

45

48

100

40

 

 

58

60

62

65

 

 

56

59

61

64

100

60

 

 

54

55

56

59

 

 

51

53

54

57

100

80

 

 

51

52

52

55

 

 

48

49

49

52

100

100

 

 

50

51

50

52

 

 

46

47

46

48

ORDERING INFORMATION

Explanation of Catalog Number. Example: XT2GVA340120SOGLR

 

 

 

 

2

 

 

 

 

XT = Recessed

 

 

 

Fluorescent

 

 

 

with Flat Steel

FIXTURE

 

Lens Frame

WIDTH

XR= Recessed Fluorescent with Regressed Aluminum Lens Frame

 

G

 

 

 

VA

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CEILING

TYPE:LAMP

QUANTITY:

 

VOLTAGE:

 

 

 

 

 

 

 

OPTIONS:

G = Grid (lay-in

 

 

 

 

 

 

2, 3 or 4 Lamps

 

 

 

 

 

 

 

120 or 277

 

BALLAST

TYPE:

 

Add appropriate

 

T-bar)

 

LENS/SHIELDING

 

 

 

 

 

 

 

LAMP/

 

 

 

 

 

LE=Magnetic (T12)

 

suffix to catalog no,

 

 

 

 

 

 

TYPE:

 

 

 

FIXTURE LENGTH:

 

 

 

OC=Magnetic (T8)

 

 

ie: (GLR)

 

 

 

 

 

 

 

 

 

 

 

 

VA = Virgin Acrylic

 

 

 

(Nominal 48")

 

 

SS=Electronic (T12)

 

 

 

 

 

 

 

 

 

 

 

(standard) see

 

 

 

 

 

 

 

 

 

 

 

S3=1-3 Lamp Elect. (T12)

 

 

 

 

 

 

 

 

 

 

 

options and

 

 

 

 

 

 

 

 

 

 

 

SO=Electronic Elect. (T8)

 

 

 

 

 

 

 

 

 

 

 

consult factory

 

 

 

 

 

 

 

 

 

 

 

O3=1-3 Lamp Elect. (T8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O4=1-4 Lamp Elect. (T8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIM=Dimming (T12)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PS=LOL Power Spec T8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimming Ballast

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPTIONS & ACCESSORIES

SPECIAL LENSES: Substitute VB for .125" nominal pattern 12 with 7.8 oz. average weight per square foot. Substitute VI for .125" nominal pattern 12 with 6.9 oz. average weight per square foot.

ACCESS PLATES: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP CSP.

ELECTRICAL/WIRING OPTIONS: Consult factory.

FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF.

RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF.

SPECIFICATIONS

PERFORMANCE: In an installation of 4 lamp 40 W luminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .78. To reduce glare the VCP shall be not less than 42 either lengthwise or crosswise (at 100 fc level) and the average brightness at 65 shall not exceed 718 footlamberts. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 66%.

MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing is embossed for added strength and rigidity with all edges rolled over

for safe handling. Lens frames—(XT) flat full-size steel frame, (XR) regressed full-size aluminum frame.

FINISH: Chassis exterior—white baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. LENS: Extruded virgin acrylic 3/16" square based female cones, running 45° to the panel edge, .095" nominal thickness (similar to pattern 12).

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W. Listed by Underwriters Laboratories.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier Page 2 of, Options & Accessories, Specifications, XT, XR XT2/XR2 SERIES 240/340/440, Photometry, Type, Lamp