Lightolier 4A28 Page 2 of, Features, Lamping by others, Electrical, Mounting, Labels, Type

Models: 4A28

1 2
Download 2 pages 23.4 Kb
Page 2
Image 2
Page 2 of 2

Architectural Decorative 4A28

Page 2 of 2

Features

1.Diffusing Reflector: White translucent acrylic, 3/16” thick.

2.Inner Dirt Shield: White translucent acrylic, 1/8” thick.

3.Chassis: Steel, 20 gauge, semi-gloss white powder-coat finish.

4.Suspension: Swivel (central) stem, 3/4” steel tube. Canopy, 7” Dia., fas- tened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45°. Complies with California Code.

5.Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4 lamp base.

Lamping (by others)

Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.

 

 

 

 

General Electric

 

 

Osram/Sylvania

 

 

Philips

26W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

 

F26TBX/*/A/4P

 

 

CF26DT/E/IN/*

 

 

PL-T26W/*/4P

 

 

 

32W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

 

F32TBX/*/A/4P

 

 

CF32DT/E/IN/*

 

 

PL-T32W/*/4P

 

 

 

 

 

42W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

 

F42QBK/*/A/4P

 

 

CF42DT/E/IN/*

 

 

PL-T42W/*/4P

*Manufacturers’ color temperature designation.

 

 

 

 

Electrical

Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage 120/277V, Multi-Wattage 26/32/42W.

4 Lamps

 

26 Watt

 

32Watt

 

42Watt

 

 

 

 

 

Voltage

 

120V

277V

 

120V

277V

120V

 

277V

Total Input Watts

 

110

110

 

140

140

186

 

186

Max. Line Current (amps)

 

1.11

0.48

 

1.40

0.60

0.60

 

0.80

Power Factor

 

>0.98

>0.98

 

>0.98

>0.98

>0.99

 

>0.99

Ballast Factor

 

1.02

1.02

 

0.96

0.96

0.95

 

0.95

THD<10% Minimum Starting Temperature: -5°F/-20°C

Mounting

Mounts directly to 4” outlet box, using crossbar hanger, supplied.

Labels

cULus listed suitable for damp locations.

Application Data

28 Inch Diameter

 

 

 

 

30’ x 30’ x 10’ Space

 

 

 

Luminaire

 

Spacing: 10’ x 10’

 

 

 

 

Susp. Dist. 28”

 

4 Lamps

 

26W

 

32W

42W

 

 

TTT

 

TTT

TTT

Illum. (FC)

 

30

 

41

54

Maint.

 

 

 

 

 

Lum.

 

8/1

 

8/1

9/1

Ratio

 

 

 

 

 

Watts/

 

1.10

 

1.36

1.86

Sq. Ft.

 

 

 

 

 

 

 

 

 

 

 

Reflectances: 80% Ceiling, 50% Walls, 20% Floor.

Light Loss Factor = .75 (.88 BF x .85)

FC (footcandles) at 30” work plane.

Pendalux Cirrus 28” Diameter Body 4-26/32/42 Triple Tube

CERTIFIED TEST REPORT NO. 4A28442

COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE

CAT. #4A28442APBU, HOUSING COVER WITHOUT FLANGE, 28” DIFFUSER 4-42W PLT TRIPLE TUBE PHILIPS LAMPS. LUMEN RATING = 3200 LMS.

2-ADVANCE BALLAST, #ICF-2S42-M2-LD, 120 VAC

 

 

 

 

CANDLEPOWER SUMMARY

 

 

 

 

ANGLE MEAN CP LUMENS

ANGLE MEAN CP LUMENS

 

 

 

0

395

 

 

90

53

 

 

 

 

5

394

38

 

95

121

199

 

 

 

10

389

 

 

100

433

 

 

 

 

15

382

108

 

105

834

871

 

 

 

20

372

 

 

110

1193

 

 

 

 

25

360

166

 

115

1470

1453

 

 

 

30

342

 

 

120

1722

 

 

 

 

35

321

201

 

125

1912

1704

 

 

 

40

297

 

 

130

2053

 

 

 

 

45

272

211

 

135

2149

1656

 

 

 

50

247

 

 

140

2203

 

 

 

 

55

221

198

 

145

2215

1386

 

 

 

60

193

 

 

150

2192

 

 

 

 

65

165

165

 

155

2178

1005

 

 

 

70

141

 

 

160

2136

 

 

 

 

75

116

123

 

165

1949

546

 

 

 

80

92

 

 

170

1666

 

 

 

 

85

71

78

 

175

1624

159

 

 

 

90

53

 

 

180

1756

 

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

ZONE

LUMENS

% LAMP

%LUMINAIRE

 

DATE: OCT. 4, 2000

 

 

PREPARED FOR:

0-30

311

 

2.43

3.03

 

 

LIGHTOLIER, FALL RIVER, MA

0-40

512

 

4.01

5.00

 

 

 

0-60

920

 

7.20

8.97

 

 

 

0-90

1287

10.06

12.54

 

 

 

40-90

774

 

6.05

7.55

 

 

 

60-90

366

 

2.86

3.57

 

 

 

90-180

8978

70.15

87.46

 

 

 

0-180

10266

80.21

100.00

 

** EFFICIENCY = 80.2% **

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD

%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

 

80

 

 

70

 

 

50

 

 

30

 

 

10

 

 

 

 

 

50

30

10

50

30

10

50

30

10

50

30

10

50

30

10

0

 

1

.68 .65 .63

.60 .57 .54

.44 .42 .41

.29 .28 .27

.15 .15 .14

.08

RATIO

2

.59 .55 .51

.52 .48 .45

.38 .35 .33

.25 .24 .22

.13 .13 .12

.07

3

.52 .47 .42

.46 .41 .37

.33 .30 .28

.22 .21 .19

.12 .11 .10

.06

 

CAVITY

4

.46 .40 .36

.40 .35 .32

.30 .26 .24

.20 .18 .16

.10 .10 .09

.05

6

.36 .30 .26

.32 .27 .23

.24 .20 .17

.16 .14 .12

.08 .07 .07

.04

ROOM

5

.40 .35 .30

.36 .31 .27

.26 .23 .20

.18 .15 .14

.09 .08 .08

.04

7

.32 .26 .22

.28 .23 .20

.21 .18 .15

.14 .12 .10

.08 .06 .06

.03

 

 

8

.38 .29 .19

.26 .21 .17

.19 .16 .13

.13 .11 .09

.07 .06 .05

.03

 

9

.36 .26 .17

.23 .18 .15

.17 .14 .11

.12 .09

.08

.06 .05 .04

.02

 

10

.33 .24 .15

.21 .16 .13

.16 .12 .10

.11 .08

.07

.06 .05 .04

.02

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

Job Information

Type:

 

 

Lightolier a Genlyte company

 

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • B0605

Page 2
Image 2
Lightolier 4A28 specifications Page 2 of, Features, Lamping by others, Electrical, Mounting, Labels, Application Data, Type