Features

1.Diffusing Reflector: White translucent acrylic, 3/16” thick.

2.Inner Dirt Shield: White translucent acrylic, 1/8” thick.

3.Chassis: Steel, 20 gauge, semi-gloss white powder-coat finish.

4.Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, 7” Dia., fas- tened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45˚. Complies with California Code.

5.Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4 lamp base.

Lamping (by others)

Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.

 

 

General Electric

 

Osram/Sylvania

 

 

 

Philips

26W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

 

 

F26TBX/*/A/4P

 

 

CF26DT/E/IN/*

 

 

 

PL-T26W/*/4P

 

 

 

 

 

 

 

 

32W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

 

 

F32TBX/*/A/4P

 

 

CF32DT/E/IN/*

 

 

 

PL-T32W/*/4P

 

 

 

 

 

 

 

42W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

 

 

F42QBK/*/A/4P

 

CF42DT/E/IN/*

 

 

 

PL-T42W/*/4P

 

 

 

 

*Manufacturers’ color temperature designation.

 

 

 

 

 

Electrical

Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage

120/277V, Multi-Wattage 26/32/42W.

 

 

 

 

 

 

 

6 Lamp

 

26 Watt

 

32Watt

 

42Watt

 

 

 

 

 

Voltage

 

120V

 

277V

 

120V

 

277V

120V

 

277V

 

 

 

 

 

Total Input Watts

 

168

 

168

 

210

 

210

279

 

372

Max. Line Current (amps)

 

2.22

 

0.96

 

2.80

 

1.20

1.20

 

1.60

Power Factor

 

>0.98

 

>0.98

 

>0.98

 

>0.98

>0.99

 

>0.99

Ballast Factor

 

1.02

 

1.02

 

0.96

 

0.96

0.95

 

0.95

THD<10% Minimum Starting Temperature: -5°F/-20°C

Mounting

Mounts directly to 4” outlet box, using crossbar hanger, supplied.

Labels

cULus listed suitable for damp locations.

Application Data

35 Inch Diameter

 

 

 

36’ x 36’ x 11’ Space

 

 

 

Luminaire

 

Spacing: 12’ x 12’

 

 

 

Susp. Dist. 35”

 

6 Lamps

26W

 

32W

42W

 

TTT

 

TTT

TTT

Illum. (FC)

33

 

44

58

Maint.

 

 

 

 

Lum.

8/1

 

8/1

9/1

Ratio

 

 

 

 

Watts/

1.15

 

1.42

1.94

Sq. Ft.

 

 

 

 

 

 

 

 

 

Reflectances: 80% Ceiling, 50% Walls, 20% Floor.

Light Loss Factor = .75 (.88 BF x .85)

FC (footcandles) at 30” work plane.

Pendalux Cirrus 35” Diameter Body 6-26/32/42 Triple Tube

CERTIFIED TEST REPORT NO. 4A35642A

COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE

CAT. #4A353642APBU, 35” DIFFUSER

6-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS.

3-ADVANCE BALLAST #ICF-2S42-M2-LD, 120 VAC

 

 

ANGLE

CANDLEPOWER SUMMARY

 

 

 

MEAN CP

LUMENS

ANGLE

MEAN CP

LUMENS

 

 

0

655

 

90

90

 

 

 

5

653

62

95

280

422

 

 

10

645

 

100

896

 

 

 

15

632

179

105

1385

1435

 

 

20

613

 

110

1760

 

 

 

25

591

273

115

2112

2095

 

 

30

566

 

120

2458

 

 

 

35

534

334

125

2759

2453

 

 

40

493

 

130

2960

 

 

 

45

451

349

135

3096

2391

 

 

50

406

 

140

3197

 

 

 

55

361

324

145

3262

2045

 

 

60

315

 

150

3303

 

 

 

65

268

267

155

3356

1548

 

 

70

226

 

160

3367

 

 

 

75

184

196

165

3147

882

 

 

80

146

 

170

2778

 

 

 

85

110

124

175

2734

268

 

 

90

90

 

180

2972

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

 

 

 

 

DATE: DEC. 14, 2000

 

ZONE

LUMENS% LAMP%LUMINAIRE

 

PREPARED FOR:

0-30

514

 

2.68

3.29

 

LIGHTOLIER, FALL RIVER, MA

0-40

848

 

4.42

5.42

 

 

0-60

1520

 

7.92

9.72

 

 

 

 

 

0-90

2107

10.98

13.47

 

 

40-90

1259

 

6.56

8.05

 

 

60-90

587

 

3.06

3.75

 

 

90-180

13538

70.51

86.53

 

 

0-180

15646

81.49

100.00

 

 

 

** EFFICIENCY = 81.5% **

 

 

 

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

 

80

 

 

70

 

 

50

 

 

30

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

30

10

50

30

10

50

30

10

50

30

10

50

30

10

0

 

1

.69 .66 .64

.61 .58 .55

.45 .43 .42

.30 .29 .28

.16 .16 .15

.08

 

2

.60 .56 .52

.53 .49 .46

.39 .36 .34

.26 .24 .23

.14 .13 .13

.07

RATIO

3

.53 .48 .43

.47 .42 .38

.34 .31 .29

.23 .21 .20

.12 .11 .11

.06

4

.47 .41 .36

.41 .36 .32

.30 .27 .24

.20 .18 .17

.11 .10 .09

.05

CAVITY

6

.37 .31 .26

.33 .27 .23

.24 .21 .18

.16 .14 .12

.09 .08 .07

.04

 

5

.41 .35 .31

.37 .31 .27

.27 .23 .21

.18 .16 .14

.10 .09 .08

.04

ROOM

7

.33 .27 .23

.29 .24 .20

.22 .18 .15

.15 .12 .11

.08

.07 .06

.03

 

 

8

.30 .24 .20

.26 .21 .18

.19 .16 .13

.13 .11 .09

.07 .06 .06

.03

 

9

.27 .21 .17

.24 .19 .15

.18 .14 .12

.12 .10

.08

.07 .05 .05

.02

 

10

.24 .19 .15

.22 .17 .14

.16 .13 .10

.11 .09

.07

.06

.05 .04

.02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

 

Job Information

Type:

 

 

 

 

Lightolier a Genlyte company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2006 Genlyte Group LLC • C0406

Page 2
Image 2
Lightolier 4A35 specifications Page 2 of, Features, Lamping by others, Electrical, Mounting, Labels, Application Data, Type