Lightolier 4F23 Page 2 of, Features, Lamping by others, Electrical, Mounting, Labels, Type

Models: 4F23

1 2
Download 2 pages 15.61 Kb
Page 2
Image 2
Architectural Decorative 4F23

Architectural Decorative 4F23

Page 2 of 2

Pendalux Gemini 23” Diameter Body 2-26/32/42 Triple Tube

Features

1.Diffusing Reflector: White translucent acrylic, 3/16” thick.

2.Inner Dirt Shield: White translucent acrylic, 1/8” thick.

3.Chassis: Steel, 20 gauge, semi-gloss white powder-coat finish.

4.Suspension: Swivel (central) stem, 3/4” steel tube. Canopy, 7” Dia., fas- tened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45˚. Complies with California Code.

5.Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4 lamp base.

6.Flange Trim: Steel 20 gauge, Plated or Painted finish.

Lamping (by others)

Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.

 

 

 

 

General Electric

 

 

Osram/Sylvania

 

 

Philips

26W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

 

F26TBX/*/A/4P

 

 

CF26DT/E/IN/*

 

 

PL-T26W/*/4P

 

 

 

32W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

 

F32TBX/*/A/4P

 

 

CF32DT/E/IN/*

 

 

PL-T32W/*/4P

 

 

 

 

 

42W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

 

F42QBK/*/A/4P

 

 

CF42DT/E/IN/*

 

 

PL-T42W/*/4P

*Manufacturers’ color temperature designation.

 

 

 

 

Electrical

Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage N120/277V, Multi-Wattage 26/32/42W.

4 Lamp

26 Watt

 

32Watt

 

42Watt

 

Voltage

120V

 

277V

120V

277V

120V

277V

Total Input Watts

55

 

55

68

68

93

93

Max. Line Current (amps)

2.22

 

0.96

2.80

1.20

1.20

1.60

Power Factor

>0.98

 

>0.98

>0.98

>0.98

>0.99

>0.99

Ballast Factor

1.02

 

1.02

0.96

0.96

0.95

0.95

THD<10% Minimum Starting Temperature: -5°F/-20°C.

Mounting

Mounts directly to 4” outlet box, using crossbar hanger, supplied.

Labels

cULus listed (suitable for damp locations).

23 Inch Diameter

 

 

 

 

24’ x 24’ x 9.5’ Space

 

 

 

Luminaire

 

Spacing: 8’ x 8’

 

 

 

 

Susp. Dist. 24”

 

2 Lamps

 

26W

 

32W

42W

 

 

TTT

 

TTT

TTT

Illum. (FC)

 

22

 

29

40

Maint.

 

 

 

 

 

Lum.

 

7/1

 

7/1

8/1

Ratio

 

 

 

 

 

Watts/

 

0.85

 

1.06

1.45

Sq. Ft.

 

 

 

 

 

 

 

 

 

 

 

CERTIFIED TEST REPORT NO. 4A23242A

COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE

CAT. #4A23242, 23” DIFFUSER

2-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS.

ADVANCE BALLAST #ICF-2S42-M2-LD, 120VAC

 

CANDLEPOWER SUMMARY

 

ANGLE

MEAN CP

LUMENS

 

 

 

ANGLE

MEAN CP

LUMENS

0

195

 

90

38

 

5

193

18

95

80

121

10

191

 

100

245

 

15

189

53

105

437

456

20

184

 

110

604

 

25

177

82

115

735

725

30

169

 

120

848

 

35

158

99

125

949

848

40

148

 

130

1035

 

45

137

106

135

1091

842

50

126

 

140

1133

 

55

113

101

145

1140

713

60

100

 

150

1125

 

65

88

87

155

1103

507

70

76

 

160

1051

 

75

64

68

165

956

267

80

53

 

170

812

 

85

42

47

175

647

65

90

38

 

180

598

 

 

 

 

 

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

DATE: DEC. 11, 2000

 

PREPARED FOR:

ZONE

LUMENS% LAMP%LUMINAIRE

 

LIGHTOLIER, FALL RIVER, MA

2.95

 

0-30

153

2.40

 

0-40

252

3.95

4.86

 

0-60

459

7.18

8.83

 

0-90

661

10.34

12.72

 

40-90

409

6.39

7.86

 

60-90

202

3.16

3.88

 

90-180

4543

70.98

87.28

 

0-180

5204

81.33

100.00

** EFFICIENCY = 81.3% **

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

80

 

 

70

 

 

50

 

 

30

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

30

10

50

30

10

50

30

10

50

30

10

50

30

10

0

1

.69 .66 .63

.60 .58 .55

.44 .43 .41

.29 .28 .27

.15 .15 .15

.08

2

.60 .55 .51

.53 .49 .45

.38 .36 .34

.25 .24 .23

.13 .13 .12

.07

3

.53 .47 .43

.46 .42 .38

.34 .31 .28

.22 .21 .19

.12 .11 .10

.06

4

.47 .41 .36

.41 .36 .32

.30 .27 .24

.20 .18 .16

.11 .10 .09

.05

5

.41 .35 .30

.36 .31 .27

.27 .23 .20

.18 .16 .14

.09 .08 .08

.04

6

.37 .31 .26

.32 .27 .23

.24 .20 .18

.16 .14 .12

.08 .07 .07

.04

7

.33 .27 .22

.29 .24 .20

.21 .18 .15

.14 .12 .10

.08 .06 .06

.03

8

.30 .24 .20

.26 .21 .17

.19 .16 .13

.13 .11 .09

.07 .06 .05

.03

9

.27 .21 .17

.23 .19 .15

.17 .14 .12

.12 .10

.08

.06 .05 .04

.02

10

.24 .19 .15

.21 .17 .13

.16 .13 .10

.11 .08

.07

.06 .05 .04

.02

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

Application Data

Reflectances: 80% Ceiling, 50% Walls, 20% Floor.

Light Loss Factor = .75(.88 BF x .85)

FC (footcandles) at 30” work plane.

Job Information

Type:

 

 

Lightolier a Genlyte company

 

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • C0605