Architectural Decorative 4F42
Page 2 of 2
Features
1.Diffusing Reflector: White translucent acrylic, 3/16” thick.
2.Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3.Chassis: Steel 20 gauge,
4.Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia. fastened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45°. Complies with California Code.
5.Multiple Stems: 3/8” Steel outer pipe stems surround center stem and go into collector plate.
6.Lampholder:
7.Flange Trim: Steel 20 gauge, Plated or Painted Finish.
Lamping (by others)
Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.
|
| General Electric |
| Osram/Sylvania | Philips | ||||||||
|
| 26W Triple Tube |
| ||||||||||
|
| F26TBX/*/A/4P |
|
| CF26DT/E/IN/* |
|
|
|
| ||||
|
|
|
|
|
| ||||||||
| 32W Triple Tube |
| |||||||||||
|
| F32TBX/*/A/4P |
|
| CF32DT/E/IN/* |
|
| ||||||
|
|
|
|
| |||||||||
42W Triple Tube |
| ||||||||||||
|
| F42QBK/*/A/4P |
| CF42DT/E/IN/* |
|
|
|
| |||||
|
|
|
|
|
| ||||||||
*Manufacturers’ color temperature designation. |
|
Electrical
Ballast: Electronic,
8 Lamps |
| 26 Watt |
| 32Watt |
|
| 42Watt |
| ||||
Voltage |
| 120V |
| 277V |
| 120V |
| 277V |
| 120V |
| 277V |
Total Input Watts |
| 224 |
| 224 |
| 276 |
| 276 |
| 364 |
| 364 |
Max. Line Current (amps) |
| 1.84 |
| 0.8 |
| 2.32 |
| 1.04 |
| 3.04 |
| 1.28 |
Power Factor |
| >.98 |
| >.98 |
| >.98 |
| >.98 |
| >.98 |
| >.99 |
Ballast Factor |
| 1.02 |
| 1.02 |
| 1.00 |
| 1.00 |
| 0.98 |
| 0.98 |
|
|
|
|
|
|
THD<10% Minimum Starting Temperature
Mounting
Mounts directly to 4” outlet box, using crossbar hanger, supplied.
Labels
cULus listed suitable for damp locations.
Application Data
42 Inch Diameter |
|
|
|
| |
45’ x 45’ x 12’ Space |
|
|
| ||
Luminaire |
| Spacing: 15’ x 15’ |
| ||
|
|
| Susp. Dist. 42” |
| |
8 Lamps |
| 26W |
| 32W | 42W |
|
| TTT |
| TTT | TTT |
Illum. (FC) |
| 29 |
| 39 | 52 |
Maint. |
|
|
|
|
|
Lum. |
| 10/1 |
| 10/1 | 11/1 |
Ratio |
|
|
|
|
|
Watts/ |
| 0.98 |
| 1.21 | 1.65 |
Sq. Ft. |
|
|
|
|
|
Reflectancies: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75 (.88 BF x .85)
FC (footcandles) at 30” work plane.
Pendalux Gemini 42” Diameter Body
CERTIFIED TEST REPORT NO. 4A42842A
COMPUTED BY LSI PROGRAM
LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE
CAT. #4A42842A, HOUSING COVER WITHOUT FLANGE, 42” DIFFUSER
|
|
|
|
| CANDLEPOWER SUMMARY |
| |||
|
|
|
|
|
| ||||
|
|
| ANGLE MEAN CP LUMENS |
| ANGLE MEAN CP LUMENS | ||||
|
|
| 0 | 890 |
| 90 | 136 |
| |
|
|
| 5 | 884 | 84 | 95 | 347 | 532 | |
|
|
| 10 | 874 |
| 100 | 1122 |
| |
|
|
| 15 | 856 | 242 | 105 | 1847 | 1900 | |
|
|
| 20 | 831 |
| 110 | 2367 |
| |
|
|
| 25 | 800 | 370 | 115 | 2832 | 2796 | |
|
|
| 30 | 763 |
| 120 | 3237 |
| |
|
|
| 35 | 721 | 452 | 125 | 3618 | 3234 | |
|
|
| 40 | 672 |
| 130 | 3949 |
| |
|
|
| 45 | 617 | 477 | 135 | 4137 | 3187 | |
|
|
| 50 | 556 |
| 140 | 4240 |
| |
|
|
| 55 | 493 | 442 | 145 | 4346 | 2737 | |
|
|
| 60 | 429 |
| 150 | 4495 |
| |
|
|
| 65 | 371 | 369 | 155 | 4491 | 2016 | |
|
|
| 70 | 314 |
| 160 | 3947 |
| |
|
|
| 75 | 261 | 277 | 165 | 3412 | 998 | |
|
|
| 80 | 212 |
| 170 | 3313 |
| |
|
|
| 85 | 166 | 186 | 175 | 3685 | 347 | |
|
|
| |||||||
| DATE: SEPT. 15, 2000 | 90 | 136 |
| 180 | 3859 |
| ||
| PREPARED FOR: |
|
|
|
|
|
|
|
|
| LIGHTOLIER, FALL RIVER, MA |
|
| ZONAL LUMENS AND PERCENTAGES | |||||
|
|
|
| ||||||
|
|
| 696 | 2.72 |
| 3.37 | |||
|
|
| 1147 | 4.48 |
| 5.56 | |||
|
|
| 2066 | 8.07 |
| 10.01 | |||
|
|
| 2898 | 11.32 |
| 14.04 | |||
|
|
| 1750 | 6.84 |
| 8.48 | |||
|
|
| 831 | 3.25 |
| 4.03 | |||
|
|
| 17747 | 69.33 |
| 85.96 | |||
|
|
| 20646 | 80.65 |
| 100.00 | |||
|
|
| ** EFFICIENCY = 80.6% ** |
|
|
|
|
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
|
| 80 |
|
| 70 |
|
| 50 |
|
| 30 |
|
| 10 |
|
|
|
|
| 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 0 |
| 1 | .69 .66 .63 | .60 .58 .55 | .44 .43 .41 | .30 .29 .28 | .16 .16 .15 | .08 | ||||||||||
| 2 | .60 .55 .51 | .52 .49 .45 | .39 .36 .34 | .26 .24 .23 | .14 .13 .13 | .07 | ||||||||||
RATIO | 3 | .53 .47 .43 | .46 .42 .38 | .34 .31 .29 | .23 .21 .20 | .12 .12 .11 | .06 | ||||||||||
4 | .46 .40 .36 | .41 .36 .32 | .30 .27 .24 | .20 .18 .17 | .11 .10 .09 | .05 | |||||||||||
CAVITY | 5 | .40 .35 .30 | .36 .31 .27 | .27 .23 .21 | .18 .16 .14 | .10 .09 .08 | .04 | ||||||||||
| |||||||||||||||||
ROOM | 6 | .37 .30 .26 | .32 .27 .23 | .24 .20 .18 | .16 .14 .12 | .09 .08 .07 | .04 | ||||||||||
8 | .39 .29 .24 | .26 .21 .17 | .19 .16 .13 | .13 .11 .09 | .07 .06 .06 | .03 | |||||||||||
| 7 | .33 .27 .22 | .29 .24 .20 | .21 .18 .15 | .15 .12 .11 | .08 .07 .06 | .03 | ||||||||||
| 9 | .36 .27 .21 | .23 .19 .15 | .18 .14 .12 | .12 .10 | .08 | .07 .05 .05 | .02 | |||||||||
| 10 | .33 .24 .19 | .21 .17 .13 | .16 .13 .10 | .11 .09 | .07 | .06 .05 .04 | .02 |
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
Job Information | Type: |
|
Lightolier a Genlyte company |
| www.lightolier.com |
631 Airport Road, Fall River, MA 02720 • (508)
© 2005 Genlyte Group LLC • C0605