Lightolier 4R35 Page 2 of, Features, Lamping by others, Electrical, Mounting, Labels, Type

Models: 4R35

1 2
Download 2 pages 12.38 Kb
Page 2
Image 2
Page 2 of 2

Architectural Decorative 4R35

Page 2 of 2

Pendalux Traditional 35" Diameter Body 6-26/32/42 Triple Tube

Features

1.Diffusing Reflector: White translucent acrylic, 3/16” thick.

2.Inner Dirt Shield: White translucent acrylic, 1/8” thick.

3.Chassis: Steel 20 gauge, semi-gloss white powder-coat finish.

4.Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia. fastened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45°. Complies with California Code.

5.Rods: Reflector Bowl is suspended from a central point on three 3/16” steel rods.

6.Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4 lamp base.

7.Flange Trim: Steel 20 gauge, Plated or Painted finish.

Lamping (by others)

Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.

General Electric

Osram/Sylvania

Philips

26W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

F26TBX/*/A/4P

CF26DT/E/IN/*

PL-T26W/*/4P

 

 

 

32W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

F32TBX/*/A/4P

CF32DT/E/IN/*

PL-T32W/*/4P

42W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

F42QBK/*/A/4P

CF42DT/E/IN/*

PL-T42W/*/4P

*Manufacturers’ color temperature designation.

Electrical

Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage

120/277V, Multi-Wattage 26/32/42W.

 

 

 

 

 

 

 

6 Lamp

 

26 Watt

 

32Watt

 

42Watt

 

 

 

 

 

Voltage

 

120V

277V

 

120V

 

277V

120V

 

277V

Total Input Watts

 

168

168

 

210

 

210

279

 

279

Max. Line Current(amps)

 

2.22

0.96

 

1.40

 

2.80

1.20

 

1.60

Power Factor

 

>0.98

>0.98

 

>0.98

 

>0.98

>0.99

 

>0.99

Ballast Factor

 

1.02

1.02

 

0.96

 

0.96

0.95

 

0.95

THD <10% Minimum Starting Temperature: -5˚F/-20˚C

Mounting

Mounts directly to 4” outlet box, using crossbar hanger, supplied.

Labels

cULus Suitable for Damp Locations.

Application Data

35 Inch Diameter

36’ x 36’ x 11’ Space

Luminaire

 

Spacing: 12’ x 12’

 

 

 

Susp. Dist. 35”

 

2 Lamps

26W

32W

42W

 

TTT

TTT

TTT

 

 

 

 

Illum. (FC) Maint.

28

37

49

Lum.Ratio

8/1

8/1

8/1

 

 

 

 

Watts/Sq. Ft.

1.15

1.42

1.94

Reflectancies: 80% Ceiling, 50% Walls, 20% Floor.

Light Loss Factor = .75 (.88 BF x .85)

FC (footcandles) at 30” work plane.

CERTIFIED TEST REPORT NO. 4R35642A

COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE

CAT. #4R35642SNU, 35” DIFFUSER

6-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS.

3-ADVANCE BALLAST #ICF-2S42-M2-LD, 120 VAC

 

 

 

 

CANDLEPOWER SUMMARY

 

 

 

 

ANGLE

MEAN CP

LUMENS

ANGLE MEAN CP

LUMENS

 

 

 

0

495

 

90

44

 

 

 

 

5

497

47

95

235

347

 

 

 

10

490

 

100

757

 

 

 

 

15

480

136

105

1311

1339

 

 

 

20

468

 

110

1681

 

 

 

 

25

450

208

115

1932

1913

 

 

 

30

430

 

120

2163

 

 

 

 

35

404

253

125

2341

2083

 

 

 

40

373

 

130

2442

 

 

 

 

45

340

263

135

2546

1973

 

 

 

50

304

 

140

2654

 

 

 

 

55

268

240

145

2727

1707

 

 

 

60

231

 

150

2764

 

 

 

 

65

190

190

155

2785

1290

 

 

 

70

154

 

160

2818

 

 

 

 

75

118

126

165

2679

750

 

 

 

80

85

 

170

2401

 

 

 

 

85

56

68

175

2363

231

 

 

 

90

44

 

180

2540

 

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

ZONE

LUMENS% LAMP%LUMINAIRE

 

 

 

 

 

 

 

 

DATE: MAR. 1, 2001

 

0-30

424

2.22

3.23

 

 

PREPARED FOR:

 

0-40

699

3.64

5.31

 

 

LIGHTOLIER, FALL RIVER, MA

 

0-60

1246

6.48

9.47

 

 

 

 

0-90

1659

 

8.64

12.62

 

 

 

 

 

 

 

 

 

40-90

1069

5.01

7.31

 

 

 

 

60-90

414

2.16

3.15

 

 

 

 

90-180

12631

65.79

95.98

 

 

 

 

0-180

14269

74.43

100.00

 

 

 

 

 

**

EFFICIENCY = 74.4%

**

 

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

80

 

 

70

 

 

50

 

 

30

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

30

10

50

30

10

50

30

10

50

30

10

50

30

10

0

1

.58 .55 .53

.51 .49 .46

.37 .36 .35

.24 .24 .23

.13 .12 .12

.08

2

.51 .47 .43

.44 .41 .38

.32 .30 .28

.21 .20 .19

.11

.10 .10

.07

3

.45 .40 .36

.35 .35 .32

.29 .26 .24

.19 .17 .16

.10 .09 .09

.06

4

.39 .34 .31

.34 .30 .27

.25 .22 .20

.17 .15 .14

.09 .08 .07

.05

5

.34 .30 .26

.31 .26 .23

.22 .20 .17

.15 .13 .12

.08 .07 .06

.04

6

.31 .26 .22

.27 .23 .20

.20 .17 .15

.13 .12 .10

.07 .06 .06

.04

7

.28 .23 .19

.24 .20 .17

.18 .15 .13

.12 .10 .09

.06 .05 .05

.03

8

.25 .20 .17

.22 .18 .15

.16 .13 .11

.11 .09 .08

.06 .05 .04

.03

9

.22 .18 .14

.20 .16 .13

.15 .12 .10

.10 .08

.07

.05 .04 .04

.02

10

.20 .16 .13

.18 .14 .11

.13 .11 .09

.09 .07

.06

.05 .04 .03

.02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

 

Job Information

Type:

 

 

 

 

Lightolier a Genlyte company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2006 Genlyte Group LLC • B0406

Page 2
Image 2
Lightolier 4R35 specifications Page 2 of, Features, Lamping by others, Electrical, Mounting, Labels, Application Data, Type