Lightolier 4X9PL Page 2 of, 32W Triple Tube, Specular clear Reflector Trim, Job Information, Type

Models: 4X9PL

1 2
Download 2 pages 19.73 Kb
Page 2
Image 2
Calculite® Matrix® Lensed Downlight  4X9PL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calculite® Matrix® Lensed Downlight4X9PL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 2 of 2

 

 

 

4 1/2" X 9" Rectangular Aperture (1) 26W Quad/32/42/57W Triple Tube Prismatic Lens

26W Triple Tube, Specular clear Reflector Trim

32W Triple Tube, Specular clear Reflector Trim

One Sylvania lamp, 1800 lumens

 

 

 

 

 

CANDLEPOWER SUMMARY

 

 

Test Report

 

 

1624FR

 

 

Feb. 26, 2002

Angle

Along

 

22.5

45

67.5

Across

Lumens

 

 

 

 

0

 

484

 

 

484

484

484

484

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

491

 

 

490

490

490

485

47

 

 

 

 

 

 

 

 

 

 

10

 

497

 

 

497

499

496

488

 

 

 

 

 

 

 

 

 

 

 

15

 

501

 

 

504

504

493

481

140

 

 

 

 

 

 

 

 

 

 

20

 

493

 

 

499

498

471

449

 

 

 

 

 

 

 

 

 

 

 

25

 

460

 

 

471

468

426

395

205

 

 

 

 

 

 

 

 

 

 

30

 

403

 

 

419

411

361

331

 

 

 

 

 

 

 

 

 

 

 

35

 

333

 

 

347

334

289

262

198

 

 

 

 

 

 

 

 

 

 

40

 

259

 

 

266

242

210

187

 

 

 

 

 

 

 

 

 

 

 

45

 

188

 

 

189

162

142

128

129

 

 

 

 

 

 

 

 

 

 

50

 

131

 

126

101

88

 

71

 

 

 

 

 

 

 

 

 

 

 

55

 

85

 

 

79

56

33

 

16

53

 

 

 

 

 

 

 

 

 

 

60

 

51

 

41

23

3

 

1

 

 

 

 

 

 

 

 

 

 

 

65

 

19

 

17

3

0

 

0

10

 

 

 

 

 

 

 

 

 

 

70

 

5

 

 

4

0

0

 

0

 

 

 

 

 

 

 

 

 

 

 

75

 

0

 

 

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

80

 

0

 

 

0

0

0

 

0

 

 

 

 

 

 

 

 

 

 

 

85

 

0

 

 

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

90

 

0

 

 

0

0

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

 

 

 

 

 

 

Zone

Lumens

% Lamp

 

% Luminaire

 

 

 

 

 

 

 

 

 

 

0-30

391

 

21.76

 

50.13

 

 

 

 

 

 

 

 

 

 

0-40

589

 

32.74

 

75.41

 

 

 

 

 

 

 

 

 

 

0-60

771

 

42.84

 

98.68

 

 

 

 

 

 

 

 

 

 

0-90

781

 

43.41

 

100.00

 

EFFICIENCY = 43.4%

 

Spacing Criterion: Along = 1.2Across = 1.1

 

 

 

 

 

 

 

cu

 

 

 

 

 

% Effective Ceiling Cavity Reflectance

 

 

 

 

 

 

 

 

 

80

 

 

70

 

 

 

50

 

 

 

30

 

 

10

 

0

 

50

30

10

50

30

10

 

50

30

10

 

50

30

10

50

30

10

0

 

 

1

.48

.47

.46

.47

.46

.45

 

.45

.45

.44

 

.44

.43

.42

.42

.42

.41

.41

 

RATIO

2

.45

.43

.41

.44

.42

.41

 

.42

.41

.40

 

.41

.40

.39

.40

.39

.38

.38

 

3

.41

.39

.37

.41

.39

.37

 

.40

.38

.36

 

.39

.37

.36

.38

.36

.35

.35

 

CAVITY

4

.38

.36

.34

.38

.36

.34

 

.37

.35

.33

 

.36

.34

.33

.35

.34

.33

.32

 

5

.36

.33

.31

.35

.33

.31

 

.34

.32

.31

 

.34

.32

.30

.33

.31

.30

.29

 

ROOM

6

.33

.30

.28

.33

.30

.28

 

.32

.30

.28

 

.31

.29

.28

.31

.29

.28

.27

 

7

.30

.28

.26

.30

.27

.25

 

.30

.27

.25

 

.29

.27

.25

.28

.27

.25

.24

 

 

8

.28

.25

.23

.28

.25

.23

 

.27

.25

.23

 

.27

.25

.23

.26

.24

.23

.22

 

 

9

.26

.23

.21

.26

.23

.21

 

.25

.23

.21

 

.25

.23

.21

.24

.22

.21

.20

 

 

10

.24

.21

.19

.24

.21

.19

 

.23

.21

.19

 

.23

.21

.19

.23

.21

.19

.19

 

One Sylvania lamp, 2400 lumens

 

 

 

 

 

CANDLEPOWER SUMMARY

 

 

 

 

 

 

Test Report

 

 

1617FR

 

Feb. 8, 2002

 

Angle

Along

22.5

 

45

67.5

Across

Lumens

 

 

 

 

 

0

 

877

877

 

877

877

 

877

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

910

908

 

906

902

 

900

86

 

 

 

 

 

 

 

 

 

 

 

10

 

931

929

 

915

896

 

886

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

950

948

 

920

876

 

849

257

 

 

 

 

 

 

 

 

 

 

 

20

 

949

951

 

907

826

 

783

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

905

917

 

857

758

 

702

382

 

 

 

 

 

 

 

 

 

 

 

30

 

807

831

 

771

666

 

614

 

 

 

 

 

 

 

 

 

 

 

 

 

35

 

679

699

 

644

562

 

510

388

 

 

 

 

 

 

 

 

 

 

 

40

 

537

542

 

488

425

 

376

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

390

389

 

336

293

 

264

264

 

 

 

 

 

 

 

 

 

 

 

50

 

267

258

 

213

185

 

143

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

171

161

 

115

62

 

28

108

 

 

 

 

 

 

 

 

 

 

 

60

 

103

84

 

44

2

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

39

34

 

5

0

 

0

19

 

 

 

 

 

 

 

 

 

 

 

70

 

10

7

 

0

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

0

0

 

0

0

 

0

1

 

 

 

 

 

 

 

 

 

 

 

80

 

0

0

 

0

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

85

 

0

0

 

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

90

 

0

0

 

0

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone

 

 

Lumens

% Lamp

% Luminaire

 

 

 

 

 

 

 

 

 

 

 

0-30

 

724

 

30.19

 

48.14

 

 

 

 

 

 

 

 

 

 

 

 

 

0-40

 

1112

 

46.36

 

73.95

 

 

 

 

 

 

 

 

 

 

 

 

 

0-60

 

1484

 

61.86

 

98.67

 

 

 

 

 

 

 

 

 

 

 

 

 

0-90

 

1504

 

62.70

 

100.00

 

 

 

EFFICIENCY = 62.7%

 

Spacing Criterion: Along = 1.3Across = 1.1

 

 

 

 

 

 

 

 

 

 

 

 

cu

 

 

 

 

 

% Effective Ceiling Cavity Reflectance

 

 

 

 

 

 

 

 

 

 

 

 

 

80

 

 

70

 

 

50

 

 

 

30

 

 

 

10

 

 

0

 

 

 

 

50

30

10

50

30

10

50

30

10

 

50

30

10

 

50

30

10

 

0

 

 

 

 

 

1

.69

.68

.66

.68

.66

.65

.65

.64

.63

 

.63

.62

.61

 

.61

.60

.59

 

.58

 

 

 

 

RATIO

2

.64

.62

.59

.63

.61

.59

.61

.59

.57

 

.59

.58

.56

 

.57

.56

.55

 

.54

 

 

 

 

3

.59

.56

.53

.58

.55

.53

.57

.54

.52

 

.55

.53

.51

 

.54

.52

.51

 

.50

 

 

 

 

CAVITY

4

.55

.51

.49

.54

.51

.48

.53

.50

.48

 

.52

.49

.47

 

.50

.48

.47

 

.46

 

 

 

 

5

.51

.47

.44

.50

.47

.44

.49

.46

.43

 

.48

.45

.43

 

.47

.45

.43

 

.42

 

 

 

 

ROOM

6

.47

.43

.40

.47

.43

.40

.46

.42

.40

 

.45

.42

.39

 

.44

.41

.39

 

.38

 

 

 

 

7

.43

.39

.36

.43

.39

.36

.42

.38

.36

 

.41

.38

.36

 

.40

.38

.35

 

.34

 

 

 

 

 

8

.40

.36

.33

.39

.36

.33

.39

.35

.33

 

.38

.35

.32

 

.37

.35

.32

 

.31

 

 

 

 

 

9

.37

.33

.30

.36

.33

.30

.36

.32

.30

 

.35

.32

.29

 

.35

.32

.29

 

.28

 

 

 

 

 

10

.34

.30

.27

.34

.30

.27

.33

.29

.27

 

.33

.29

.27

 

.32

.29

.27

 

.26

 

 

42W Triple Tube, Specular20% Floor CavityclearR flect nce Reflector Trim

One Sylvania lamp, 3200 lumens

 

 

 

 

 

CANDLEPOWER SUMMARY

 

 

 

Test Report

 

 

1610FR

 

 

Feb. 7, 2002

Angle

Along

 

22.5

45

67.5

Across

Lumens

 

 

 

 

0

 

1208

1208

1208

1208

1208

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

1210

1211

1208

1206

1228

116

 

 

 

 

 

 

 

 

 

 

10

 

1224

1226

1214

1197

1208

 

 

 

 

 

 

 

 

 

 

 

 

15

 

1227

1231

1209

1167

1164

338

 

 

 

 

 

 

 

 

 

 

20

 

1204

1213

1179

1097

1073

 

 

 

 

 

 

 

 

 

 

 

 

25

 

1134

1157

1105

1002

 

965

494

 

 

 

 

 

 

 

 

 

 

30

 

1012

1045

987

879

 

842

 

 

 

 

 

 

 

 

 

 

 

 

35

 

855

 

880

821

734

 

699

500

 

 

 

 

 

 

 

 

 

 

40

 

681

 

687

623

555

 

516

 

 

 

 

 

 

 

 

 

 

 

 

45

 

504

 

498

436

383

 

359

345

 

 

 

 

 

 

 

 

 

 

50

 

354

 

339

286

252

 

212

 

 

 

 

 

 

 

 

 

 

 

 

55

 

235

 

217

159

91

 

501

448

 

 

 

 

 

 

 

 

 

 

60

 

143

 

117

65

8

 

4

 

 

 

 

 

 

 

 

 

 

 

 

65

 

56

 

48

9

1

 

1

28

 

 

 

 

 

 

 

 

 

 

70

 

16

 

10

1

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

75

 

0

 

0

0

0

 

0

1

 

 

 

 

 

 

 

 

 

 

80

 

0

 

0

0

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

85

 

0

 

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

90

 

0

 

0

0

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

 

 

 

 

 

 

 

Zone

Lumens

% Lamp

 

% Luminaire

 

 

 

 

 

 

 

 

 

 

0-30

 

 

948

29.63

 

 

48.13

 

 

 

 

 

 

 

 

 

 

0-40

 

 

1447

45.24

 

 

73.50

 

 

 

 

 

 

 

 

 

 

0-60

 

 

1940

60.64

 

 

98.51

 

 

 

 

 

 

 

 

 

 

0-90

 

 

1969

61.55

 

 

100.00

 

EFFICIENCY = 61.6%

 

Spacing Criterion: Along = 1.2Across = 1.1

 

 

 

 

 

 

 

 

cu

 

 

 

 

 

% Effective Ceiling Cavity Reflectance

 

 

 

 

 

 

 

 

 

 

80

 

 

70

 

 

 

50

 

 

 

30

 

 

10

 

0

 

 

50

30

10

50

30

10

 

50

30

10

 

50

30

10

50

30

10

0

 

 

 

1

.68

.66

.65

.67

.65

.64

.64

.63

.62

 

.62

.61

.60

.60

.59

.58

.57

 

 

RATIO

2

.63

.60

.58

.62

.59

.58

.60

.58

.56

 

.58

.56

.55

.56

.55

.54

.53

 

 

3

.58

.55

.52

.57

.54

.52

.56

.53

.51

 

.54

.52

.50

.53

.51

.50

.49

 

 

 

 

 

 

CAVITY

4

.54

.50

.48

.53

.50

.47

.52

.49

.47

 

.51

.48

.46

.49

.47

.46

.45

 

 

5

.50

.46

.43

.49

.46

.43

.48

.45

.43

 

.47

.44

.42

.46

.44

.42

.41

 

 

 

 

 

 

ROOM

6

.46

.42

.39

.46

.42

.39

.45

.41

.39

 

.44

.41

.39

.43

.40

.38

.37

 

 

7

.42

.38

.36

.42

.38

.35

.41

.38

.35

 

.40

.37

.35

.40

.37

.35

.34

 

 

 

 

 

 

 

8

.39

.35

.32

.39

.35

.32

.38

.34

.32

 

.37

.34

.32

.37

.34

.32

.31

 

 

 

9

.36

.32

.29

.36

.32

.29

.35

.32

.29

 

.35

.31

.29

.34

.31

.29

.28

 

 

 

10

.33

.29

.27

.33

.29

.26

.32

.29

.26

 

.32

.29

.26

.31

.28

.26

.25

 

20% Floor Cavity Reflectance

57W Triple Tube, Specular clear Reflector Trim

One Sylvania lamp, 4300 lumens

 

 

 

 

 

CANDLEPOWER SUMMARY

 

 

 

 

Test Report

 

 

1631FR

 

Mar. 11, 2002

Angle

Along

 

22.5

45

67.5

Across

Lumens

 

 

 

0

 

1562

 

 

1562

1562

1562

1562

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

1555

 

 

1559

1562

1565

1566

149

 

 

 

 

 

 

 

 

 

 

 

10

 

1543

 

 

1550

1551

1548

1546

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

1509

 

 

1521

1523

1506

1491

426

 

 

 

 

 

 

 

 

 

 

 

20

 

1449

 

 

1467

1463

1412

1382

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

1350

 

 

1382

1352

1282

1243

610

 

 

 

 

 

 

 

 

 

 

 

30

 

1210

 

 

1250

1196

1114

1084

 

 

 

 

 

 

 

 

 

 

 

 

 

35

 

1029

 

 

1065

996

927

901

615

 

 

 

 

 

 

 

 

 

 

 

40

 

824

 

 

840

765

701

662

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

618

 

 

614

537

480

456

427

 

 

 

 

 

 

 

 

 

 

 

50

 

444

 

 

423

351

304

269

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

303

 

 

273

191

105

57

182

 

 

 

 

 

 

 

 

 

 

 

60

 

181

 

 

143

75

 

2

0

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

62

 

 

53

4

 

0

0

31

 

 

 

 

 

 

 

 

 

 

 

70

 

12

 

 

5

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

0

 

 

0

0

 

0

0

1

 

 

 

 

 

 

 

 

 

 

 

80

 

0

 

 

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

85

 

0

 

 

0

0

 

0

0

0

 

 

 

 

 

 

 

 

 

 

 

90

 

0

 

 

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone

Lumens

% Lamp

 

% Luminaire

 

 

 

 

 

 

 

 

 

 

 

0-30

 

 

1184

27.56

 

 

 

48.55

 

 

 

 

 

 

 

 

 

 

 

0-40

 

 

1799

41.86

 

 

 

73.75

 

 

 

 

 

 

 

 

 

 

 

0-60

 

 

2408

56.02

 

 

 

98.70

 

 

 

 

 

 

 

 

 

 

 

0-90

 

 

2440

56.76

 

 

 

100.00

EFFICIENCY = 56.8%

 

Spacing Criterion: Along = 1.2Across = 1.1

 

 

 

 

 

 

 

 

 

 

 

cu

 

 

 

 

 

% Effective Ceiling Cavity Reflectance

 

 

 

 

 

 

 

 

 

 

 

 

80

 

 

70

 

 

 

50

 

 

 

30

 

 

10

 

 

0

 

 

 

50

30

10

50

30

10

50

30

10

 

50

30

10

50

30

10

 

0

 

 

 

 

1

.63

.61

.60

.61

.60

.59

.59

.58

.57

 

.57

.56

.55

.55

.54

.54

 

.53

 

 

 

RATIO

2

.58

.56

.54

.57

.55

.53

.55

.53

.52

 

.54

.52

.51

.52

.51

.50

 

.49

 

 

 

3

.54

.51

.48

.53

.50

.48

.51

.49

.47

 

.50

.48

.46

.49

.47

.46

 

.45

 

 

 

4

.50

.47

.44

.49

.46

.44

.48

.45

.43

 

.47

.45

.43

.46

.44

.42

 

.41

 

 

 

CAVITY

 

 

 

 

 

5

.46

.43

.40

.46

.42

.40

.44

.42

.39

 

.44

.41

.39

.43

.41

.39

 

.38

 

 

 

6

.43

.39

.36

.42

.39

.36

.41

.38

.36

 

.40

.38

.36

.40

.37

.35

 

.35

 

 

 

ROOM

 

 

 

 

 

7

.39

.36

.33

.39

.35

.33

.38

.35

.33

 

.37

.34

.32

.37

.34

.32

 

.31

 

 

 

8

.36

.33

.30

.36

.32

.30

.35

.32

.30

 

.35

.32

.30

.34

.31

.29

 

.29

 

 

 

 

 

 

 

 

 

 

9

.33

.30

.27

.33

.30

.27

.33

.29

.27

 

.32

.29

.27

.31

.29

.27

 

.26

 

 

 

 

10

.31

.27

.25

.31 .27 .25

.30

.27

.25

 

.30

.27

.24

.29

.26

.24

 

.24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Job Information

 

 

Type:

 

 

 

 

 

 

 

 

 

20% Floor Cavity Reflectance

20% Floor Cavity Reflectance

Based on specular clear (CL) finish. To estimate other finishes, multiply can- delas and CU values by 0.95 for CCL, by 0.90 for CCD.

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • B0608

Lightolier is a Philips group brand

Page 2
Image 2
Lightolier 4X9PL Page 2 of, 32W Triple Tube, Specular clear Reflector Trim, 57W Triple Tube, Specular clear Reflector Trim