Decorative Triplex™ 5005
1200 | Surface Utility |
Page 2 of 2 |
INITIAL FOOTCANDLES
80
70
60
50
40
30
20
10
2 Light - 26W Quad Tube
1800 Lumens Per Lamp
RCR = 1 (60' x60'x8.5' room) RCR = 5 (12' x12'x8.5' room) RCR = 10 (6' x6'x8.5' room)
Room surface reflectances
80% Ceiling,50% Walls,20% Floor
20 | 40 | 60 | 80 | 100 | 120 | 140 | 180 |
|
|
|
| AREA PER FIXTURE IN SQUARE FEET |
|
|
|
|
|
|
| ||||||
3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
| 13 |
|
|
|
| ||
|
|
|
| CENTER TO CENTER DISTANCE OF FIXTURES IN FEET |
|
|
|
|
| ||||||||
Use quick calculator chart to determine the number and spacing of luminaries for |
|
|
| ||||||||||||||
a desired level of illumination. |
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| SPACING RATIO = 1.3 |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| CERTIFIED TEST REPORT NO. 0972FR |
|
|
| ||||
|
|
|
|
|
|
|
|
|
| COMPUTED BY LSI PROGRAM |
|
|
| ||||
|
|
|
|
|
|
|
|
|
| LIGHTOLIER SURFACE UTILITY FLOURESCENT |
|
|
| ||||
|
|
|
|
|
|
|
|
| CAT. 5005WH226U WITH TWIST LOCK OPAL GLASS DIFFUSER |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
| ROBERTSON BALLAST #PSM226CQMVW, 120VAC |
|
|
| |||||
180 |
| 150 |
|
| 120 |
|
|
| CANDLEPOWER DATA |
|
|
|
| ANGLE | CANDLEPOWER | LUMENS | |
|
|
| ACROSS |
|
|
|
| ANGLE | CANDLEPOWER | LUMENS | |||||||
|
|
| 45 |
|
|
|
| 0 | 391 |
|
|
|
| 95 | 108 | 118 | |
|
|
|
|
|
|
| 5 | 389 |
| 38 |
|
| 100 | 92 |
| ||
|
|
| ALONG |
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| 10 | 385 |
|
|
|
| 105 | 78 | 83 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
| 9 0 |
| 15 | 377 |
| 107 |
|
| 110 | 64 |
| |
|
|
|
|
|
|
| 20 | 368 |
|
|
|
| 115 | 53 | 53 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| 25 | 356 |
| 165 |
|
| 120 | 43 |
|
|
|
|
|
|
|
|
|
| 30 | 342 |
|
|
|
| 125 | 35 | 32 |
|
|
|
|
|
|
|
|
| 35 | 326 |
| 205 |
|
| 130 | 28 |
|
|
|
|
|
|
|
|
|
| 40 | 310 |
|
|
|
| 135 | 23 | 18 |
200 |
|
|
|
|
| 80 | 45 | 293 |
| 227 |
|
| 140 | 19 | 11 | ||
|
|
|
|
|
|
|
|
| 50 | 274 |
|
|
|
| 145 | 17 | |
|
|
|
|
|
|
|
|
| 55 | 255 |
| 230 |
|
| 150 | 16 |
|
|
|
|
|
|
|
|
|
| 60 | 236 |
|
|
|
| 155 | 16 | 8 |
400 |
|
|
|
|
|
|
|
| 65 | 217 |
| 216 |
|
| 160 | 16 |
|
|
|
|
|
|
|
|
|
| 70 | 198 |
|
|
|
| 165 | 14 | 5 |
|
|
|
|
|
|
|
|
| 75 | 179 |
| 190 |
|
| 170 | 12 |
|
|
|
|
|
|
|
|
|
| 80 | 160 |
|
|
|
| 175 | 11 | 2 |
|
|
|
|
|
|
|
|
| 85 | 142 |
| 155 |
|
| 180 | 12 |
|
600 |
|
|
|
|
|
|
|
| 90 | 121 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ZONAL LUMENS AND PERCENTAGES |
|
|
| |||||
0 |
|
|
|
|
| 30 |
| ZONE | LUMENS | % LAMP | %LUMINAIRE |
|
|
| |||
|
|
|
|
|
|
|
|
| 308 |
| 9.07 | 16.64 |
|
|
| ||
|
|
|
|
|
|
|
|
| 513 |
| 5.10 | 27.69 |
|
|
| ||
|
|
|
|
|
|
|
|
| 968 |
| 28.50 | 52.26 |
|
|
| ||
|
|
|
|
|
|
|
|
| 1528 |
| 44.96 | 82.44 |
|
|
| ||
|
|
|
|
|
|
|
|
| 1015 |
| 29.86 | 54.75 |
|
|
| ||
|
|
|
|
|
|
|
|
| 559 |
| 16.46 | 30.18 |
|
|
| ||
|
|
|
|
|
|
|
|
| 325 |
| 9.57 | 17.56 |
|
|
| ||
|
|
|
|
|
|
|
|
| 1853 |
| 54.53 | 100.00 |
|
|
|
** EFFICIENCY = 54.5% **
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
|
| 80 |
|
| 70 |
|
| 50 |
|
| 30 |
|
| 10 |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
| 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 0 | |
| 1 | .52 .50 .47 | .50 .48 .45 | .46 .44 .42 | .42 .41 .39 | .39 .37 .36 | .34 | |||||||||||
| 2 | .45 .41 .37 | .43 .39 .36 | .40 .37 .34 | .36 .34 .32 | .33 .31 .30 | .28 | |||||||||||
RATIO | 3 | .39 .34 .30 | .37 .33 .30 | .35 .31 .28 | .32 .29 .26 | .29 .27 .24 | .23 | |||||||||||
4 | .35 .30 .26 | .33 .29 .25 | .31 .27 .24 | .28 .25 .22 | .26 .23 .21 | .19 | ||||||||||||
CAVITY | 6 | .27 .22 .19 | .26 .22 .18 | .24 .20 .17 | .22 .19 .16 | .21 .18 .15 | .14 | |||||||||||
ROOM | 5 | .31 .26 .22 | .29 .25 .21 | .27 .23 .20 | .25 .22 .19 | .23 .20 .18 | .16 | |||||||||||
7 | .24 .19 .16 | .23 .19 .16 | .22 .18 .15 | .20 .17 .14 | .19 .16 .13 | .12 | ||||||||||||
| ||||||||||||||||||
| 8 | .22 .17 .14 | .21 .17 .14 | .20 .16 .13 | .18 .15 .12 | .17 .14 .12 | .11 | |||||||||||
| 9 | .20 .15 .12 | .19 .15 .12 | .18 .14 .11 | .17 .13 | .11 | .15 .12 .10 | .09 | ||||||||||
| 10 | .18 .14 .11 | .18 .13 .11 | .16 .13 .10 | .15 .12 | .10 | .14 .11 .09 | .08 |
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
Job Information |
| Type: |
Lightolier a Genlyte Thomas Company | www.lightolier.com |
631 Airport Road, Fall River, MA 02720 • (508)
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902