Image 2
1200

Decorative Triplex5005

1200

Surface Utility

Page 2 of 2

INITIAL FOOTCANDLES

80

70

60

50

40

30

20

10

2 Light - 26W Quad Tube

1800 Lumens Per Lamp

RCR = 1 (60' x60'x8.5' room) RCR = 5 (12' x12'x8.5' room) RCR = 10 (6' x6'x8.5' room)

Room surface reflectances

80% Ceiling,50% Walls,20% Floor

20

40

60

80

100

120

140

180

 

 

 

 

AREA PER FIXTURE IN SQUARE FEET

 

 

 

 

 

 

 

3

4

5

6

7

8

9

10

11

12

 

13

 

 

 

 

 

 

 

 

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

 

 

 

 

 

Use quick calculator chart to determine the number and spacing of luminaries for

 

 

 

a desired level of illumination.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPACING RATIO = 1.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CERTIFIED TEST REPORT NO. 0972FR

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPUTED BY LSI PROGRAM **TEST-LITE**

 

 

 

 

 

 

 

 

 

 

 

 

 

LIGHTOLIER SURFACE UTILITY FLOURESCENT

 

 

 

 

 

 

 

 

 

 

 

 

CAT. 5005WH226U WITH TWIST LOCK OPAL GLASS DIFFUSER

 

 

 

 

 

 

 

 

 

 

 

2-26W QUAD TUBE GE LAMPS. LUMEN RATING = 1700 LMS.

 

 

 

 

 

 

 

 

 

 

 

ROBERTSON BALLAST #PSM226CQMVW, 120VAC

 

 

 

180

 

150

 

 

120

 

 

 

CANDLEPOWER DATA

 

 

 

 

ANGLE

CANDLEPOWER

LUMENS

 

 

 

ACROSS

 

 

 

 

ANGLE

CANDLEPOWER

LUMENS

 

 

 

45

 

 

 

 

0

391

 

 

 

 

95

108

118

 

 

 

 

 

 

 

5

389

 

38

 

 

100

92

 

 

 

 

ALONG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

385

 

 

 

 

105

78

83

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9 0

 

15

377

 

107

 

 

110

64

 

 

 

 

 

 

 

 

20

368

 

 

 

 

115

53

53

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

356

 

165

 

 

120

43

 

 

 

 

 

 

 

 

 

 

30

342

 

 

 

 

125

35

32

 

 

 

 

 

 

 

 

 

35

326

 

205

 

 

130

28

 

 

 

 

 

 

 

 

 

 

40

310

 

 

 

 

135

23

18

200

 

 

 

 

 

80

45

293

 

227

 

 

140

19

11

 

 

 

 

 

 

 

 

 

50

274

 

 

 

 

145

17

 

 

 

 

 

 

 

 

 

55

255

 

230

 

 

150

16

 

 

 

 

 

 

 

 

 

 

60

236

 

 

 

 

155

16

8

400

 

 

 

 

 

 

 

 

65

217

 

216

 

 

160

16

 

 

 

 

 

 

 

 

 

 

70

198

 

 

 

 

165

14

5

 

 

 

 

 

 

 

 

 

75

179

 

190

 

 

170

12

 

 

 

 

 

 

 

 

 

 

80

160

 

 

 

 

175

11

2

 

 

 

 

 

 

 

 

 

85

142

 

155

 

 

180

12

 

600

 

 

 

 

 

 

 

 

90

121

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

0

 

 

 

 

 

30

 

ZONE

LUMENS

% LAMP

%LUMINAIRE

 

 

 

 

 

 

 

 

 

 

 

 

0-30

308

 

9.07

16.64

 

 

 

 

 

 

 

 

 

 

 

 

0-40

513

 

5.10

27.69

 

 

 

 

 

 

 

 

 

 

 

 

0-60

968

 

28.50

52.26

 

 

 

 

 

 

 

 

 

 

 

 

0-90

1528

 

44.96

82.44

 

 

 

 

 

 

 

 

 

 

 

 

40-90

1015

 

29.86

54.75

 

 

 

 

 

 

 

 

 

 

 

 

60-90

559

 

16.46

30.18

 

 

 

 

 

 

 

 

 

 

 

 

90-180

325

 

9.57

17.56

 

 

 

 

 

 

 

 

 

 

 

 

0-180

1853

 

54.53

100.00

 

 

 

** EFFICIENCY = 54.5% **

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

 

80

 

 

70

 

 

50

 

 

30

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

30

10

50

30

10

50

30

10

50

30

10

50

30

10

0

 

1

.52 .50 .47

.50 .48 .45

.46 .44 .42

.42 .41 .39

.39 .37 .36

.34

 

2

.45 .41 .37

.43 .39 .36

.40 .37 .34

.36 .34 .32

.33 .31 .30

.28

RATIO

3

.39 .34 .30

.37 .33 .30

.35 .31 .28

.32 .29 .26

.29 .27 .24

.23

4

.35 .30 .26

.33 .29 .25

.31 .27 .24

.28 .25 .22

.26 .23 .21

.19

CAVITY

6

.27 .22 .19

.26 .22 .18

.24 .20 .17

.22 .19 .16

.21 .18 .15

.14

ROOM

5

.31 .26 .22

.29 .25 .21

.27 .23 .20

.25 .22 .19

.23 .20 .18

.16

7

.24 .19 .16

.23 .19 .16

.22 .18 .15

.20 .17 .14

.19 .16 .13

.12

 

 

8

.22 .17 .14

.21 .17 .14

.20 .16 .13

.18 .15 .12

.17 .14 .12

.11

 

9

.20 .15 .12

.19 .15 .12

.18 .14 .11

.17 .13

.11

.15 .12 .10

.09

 

10

.18 .14 .11

.18 .13 .11

.16 .13 .10

.15 .12

.10

.14 .11 .09

.08

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902

Page 2
Image 2
Lightolier 5005 manual 1200, Decorative Triplex, Surface Utility, Page 2 of, Job Information, Type