| Decorative Lumidome™ Contemporary 5243 |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
| |||||||
Page 2 of 2 | Ceiling or Wall Mounted Compact Fluorescent |
INITIAL FOOTCANDLES
80
70
60
50
40
30
20
10
2 Light - 36/39W Quad Tube
2900 Lumens Per Lamp
RCR = 1 (60' x60'x8.5' room) RCR = 5 (12' x12'x8.5' room) RCR = 10 (6' x6'x8.5' room)
Room surface reflectances
80% Ceiling,50% Walls,20% Floor
25 | 50 | 75 | 100 | 125 | 150 | 175 | 200 |
AREA PER FIXTURE IN SQUARE FEET
3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 |
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
Use quick calculator chart to determine the number and spacing of luminaries for a desired level of illumination.
For 3 light - 26W Quad Tube units multiply FC’s by 0.95
SPACING RATIO = 1.3
180 | 150 | 120 |
ACROSS 45 ALONG
90
400
60
800
1200
0 | 30 |
CERTIFIED TEST REPORT NO. 1045FR
COMPUTED BY LSI PROGRAM
LIGHTOLIER SURFACE UTILITY FLOURESCENT LUMIDOME |
| ||||
CAT. 5241WH239F1 WITH TWIST LOCK ACRYLIC DIFFUSER |
|
| |||
|
| ||||
| ROBERTSON BALLAST |
|
| ||
CANDLEPOWER DATA |
|
|
|
| |
ANGLE | CANDLEPOWER | LUMENS | ANGLE CANDLEPOWER | LUMENS | |
0 | 850 |
| 95 | 83 | 92 |
5 | 846 | 81 | 100 | 62 |
|
10 | 836 |
| 105 | 49 | 54 |
15 | 819 | 232 | 110 | 41 |
|
20 | 795 |
| 115 | 39 | 39 |
25 | 766 | 354 | 120 | 38 |
|
30 | 730 |
| 125 | 38 | 35 |
35 | 688 | 432 | 130 | 39 |
|
40 | 640 |
| 135 | 39 | 30 |
45 | 589 | 456 | 140 | 38 |
|
50 | 532 |
| 145 | 38 | 25 |
55 | 472 | 423 | 150 | 38 |
|
60 | 410 |
| 155 | 38 | 18 |
65 | 349 | 348 | 160 | 37 |
|
70 | 291 |
| 165 | 35 | 10 |
75 | 237 | 253 | 170 | 31 |
|
80 | 189 |
| 175 | 32 | 4 |
85 | 147 | 162 | 180 | 33 |
|
90 | 108 |
|
|
|
|
ZONAL LUMENS AND PERCENTAGES |
|
|
| ||
ZONE | LUMENS | % LAMP | %LUMINAIRE |
|
|
666 | 11.48 | 21.92 |
|
| |
1097 | 18.92 | 36.11 |
|
| |
1975 | 34.05 | 65.01 |
|
| |
2735 | 47.17 | 90.04 |
|
| |
1638 | 28.25 | 53.93 | TESTED ACCORDING TO IES | ||
760 | 13.12 | 25.03 | |||
302 | 5.22 | 9.96 | PROCEDURES. TEST DISTANCE EXCEEDS | ||
3038 | 52.39 | 100.00 | FIVE TIMES THE GREATEST LUMINOUS | ||
** EFFICIENCY = 52.4% ** |
|
| OPENING OF LUMINAIRE. | ||
|
|
|
|
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
|
| 80 |
| 70 |
| 50 |
| 30 |
| 10 |
|
|
|
|
|
|
|
| |||||
|
| 50 30 10 |
| 50 30 10 |
| 50 30 10 |
| 50 30 | 10 | 50 30 10 | 0 |
| 1 | .53 .50 .48 |
| .51 .49 .47 |
| .48 .46 .44 |
| .45 .43 .42 | .42 .41 .40 | .38 | |
RATIO | 2 | .46 .42 .39 |
| .44 .41 .38 |
| .42 .39 .37 |
| .39 .37 .35 | .37 .35 .33 | .32 | |
4 | .36 .31 .28 |
| .35 .31 .27 |
| .33 .29 .26 |
| .31 .28 .26 | .29 .27 .25 | .23 | ||
CAVITY | 3 | .40 .36 .33 |
| .39 .35 .32 |
| .37 .33 .31 |
| .35 .32 .29 | .33 .30 .28 | .27 | |
6 | .29 .24 .21 |
| .28 .23 .20 |
| .26 .23 .20 |
| .25 .22 .19 | .24 .21 .18 | .17 | ||
ROOM | 5 | .32 .27 .24 |
| .31 .27 .23 |
| .29 .26 .23 |
| .28 .24 .22 | .26 .24 .21 | .20 | |
8 | .23 .19 .16 |
| .22 .18 .15 |
| .21 .18 .15 |
| .20 .17 .15 | .19 .16 .14 | .13 | ||
| 7 | .26 .21 .18 |
| .25 .21.17 |
| .24 .20 .17 |
| .22 .19 .16 | .21 .18 .16 | .15 | |
| 9 | .21 .17 .14 |
| .21 .16 .14 |
| .19 .16 .13 |
| .19 .15 | .13 | .18 .15 .12 | .11 |
| 10 | .19 .15 .12 |
| .19 .15 .12 |
| .18 .14 .12 |
| .17 .14 | .11 | .16 .13 .11 | .10 |
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES For 3 light - 26W Quad Tube units multiply CU’s by 0.95
Job Information | Type: |
Lightolier a Genlyte company | www.lightolier.com |
631 Airport Road, Fall River, MA 02720 • (508)
© 2005 Genlyte Group LLC • B0305