INITIAL FOOTCANDLES
50
70
60
50
40
30
20
10
2 Light - 26W Quad Tube
1800 Lumens Per Lamp
RCR = 1 (60' x60'x8.5' room) RCR = 5 (12' x12'x8.5' room) RCR = 10 (6' x6'x8.5' room)
Room surface reflectances
80% Ceiling,50% Walls,20% Floor
|
| 20 |
| 40 | 60 | 80 | 100 | 120 |
|
|
| AREA PER FIXTURE IN SQUARE FEET |
| ||||
3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
Use quick calculator chart to determine the number and spacing of luminaries for a desired level of illumination.
SPACING RATIO = 1.3
|
|
|
|
|
|
|
| CERTIFIED TEST REPORT NO. 1104FR |
|
| ||
|
|
|
|
|
|
|
| COMPUTED BY LSI PROGRAM |
|
| ||
|
|
|
|
|
|
| LIGHTOLIER SURFACE UTILITY FLOURESCENT SPILL RING |
|
| |||
|
|
|
|
|
|
|
| CAT.# 5533WH226U WITH ENCLOSED ACRYLIC DIFFUSER |
|
| ||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| ROBERTSON BALLAST #PSM226CQMVW,120VAC |
|
| ||
180 | 150 | 120 |
|
| CANDLEPOWER DATA |
| ANGLE | CANDLEPOWER | LUMENS | |||
|
|
| ACROSS |
|
|
| ANGLE | CANDLEPOWER | LUMENS | |||
|
|
| 45 |
|
|
| 0 | 402 |
| 95 | 52 | 58 |
|
|
|
|
|
| 5 | 401 | 39 | 100 | 40 |
| |
|
|
| ALONG |
|
| |||||||
|
|
|
| 10 | 396 |
| 105 | 30 | 32 | |||
|
|
|
|
|
|
| 15 | 388 | 110 | 110 | 22 |
|
|
|
| 90 |
| 20 | 377 |
| 115 | 18 | 18 | ||
|
|
|
|
|
|
| 25 | 363 | 168 | 120 | 15 |
|
|
|
|
|
|
|
| 30 | 346 |
| 125 | 13 | 12 |
|
|
|
|
|
|
| 35 | 326 | 205 | 130 | 11 |
|
|
|
|
|
|
|
| 40 | 304 |
| 135 | 10 | 8 |
| 200 |
|
|
|
|
|
| |||||
|
| 80 | 45 | 281 | 217 | 140 | 9 |
| ||||
|
|
| 6 | |||||||||
|
|
|
|
|
|
| 50 | 255 |
| 145 | 9 | |
|
|
|
|
|
|
| 55 | 227 | 205 | 150 | 8 |
|
|
|
|
|
|
|
| 60 | 200 |
| 155 | 8 | 4 |
400 |
|
|
|
|
| 65 | 175 | 174 | 160 | 7 |
| |
|
|
|
|
|
|
| 70 | 150 |
| 165 | 6 | 2 |
|
|
|
|
|
|
| 75 | 127 | 136 | 170 | 5 |
|
|
|
|
|
|
|
| 80 | 106 |
| 175 | 5 | 1 |
|
|
|
|
|
|
| 85 | 86 | 94 | 80 | 5 |
|
600 |
|
|
|
|
| 90 | 66 |
|
|
|
| |
0 |
| 30 |
| ZONAL LUMENS AND PERCENTAGES |
|
|
| |||||
|
| ZONE | LUMENS | % LAMP | %LUMINAIRE |
|
| |||||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| 315 | 8.77 | 21.29 |
|
| |
|
|
|
|
|
|
| 520 | 14.45 | 35.10 |
|
| |
|
|
|
|
|
|
| 941 | 26.14 | 63.50 |
|
| |
|
|
|
|
|
|
| 1343 | 37.33 | 90.68 |
|
| |
|
|
|
|
|
|
| 823 | 22.88 | 55.58 |
|
| |
|
|
|
|
|
|
| 402 | 11.19 | 27.18 |
|
| |
|
|
|
|
|
|
| 138 | 3.84 | 9.32 |
|
| |
|
|
|
|
|
|
| 1481 | 41.16 | 100.00 |
|
| |
|
|
|
|
|
|
| ** EFFICIENCY = 41.2% ** |
|
|
|
| |
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE. | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD |
|
|
| ||||||||||||
|
|
| %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20 |
|
|
|
|
| ||||||||||
|
|
| 80 |
| 70 |
| 50 |
| 30 |
| 10 |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
| 50 30 10 |
| 50 30 10 |
| 50 | 30 10 |
| 50 30 10 |
| 50 | 30 10 | 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
| 1 | .41 .39 .37 |
| .40 .38 .36 |
| .37 .36 .34 |
| 35 .34 .33 |
| .33 | .32 .31 | .30 |
|
|
|
| |
| RATIO | 2 | .36 .33 .30 |
| .35 .32 .30 |
| .32 .30 .28 |
| .31 .29 .27 |
| .29 | .27 .26 | .25 |
|
|
|
| |
| 4 | .28 .24 .21 |
| .27 .24 .21 |
| .26 .23 .20 |
| .24 .22 .20 |
| .23 | .21 .19 | .18 |
|
|
|
| ||
| CAVITY | 3 | .31 .28 .25 |
| .30 .27 .25 |
| .29 .26 .24 |
| .27 .25 .23 |
| .25 | .23 .22 | .21 |
|
|
|
| |
| 6 | .22 .18 .16 |
| .22 .18 .15 |
| .20 .17 .15 |
| .19 .17 .15 |
| .18 | .16 .14 | .13 |
|
|
|
| ||
| ROOM | 5 | .25 .21 .18 |
| .24 .21 .18 |
| .23 .20 .17 |
| .22 .19 .17 |
| .20 | .18 .16 | .15 |
|
|
|
| |
| 8 | .18 .14 .12 |
| .17 .14 .12 |
| .17 .14 .11 |
| .16 .13 .11 |
| .15 | .13 .11 | .10 |
|
|
|
| ||
|
| 7 | .20 .16 .14 |
| .19 .16 .13 |
| .18 .15 .13 |
| .17 .15 .13 |
| .17 | .14 .12 | .11 |
|
|
|
| |
|
| 9 | .16 .13 .10 |
| .16 .13 .10 |
| .15 .12 .10 |
| .14 .12 .10 |
| .14 | .11 .10 | .09 |
|
|
|
| |
|
| 10 | .15 .11 .09 |
| .14 .11 .09 |
| .14 .11 .09 |
| .13 .11 .09 |
| .13 | .10 .08 | .08 |
|
|
|
| |
|
| DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES |
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Job Information | Type: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Lightolier a Genlyte company | www.lightolier.com |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 631 Airport Road, Fall River, MA 02720 • (508) | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| We reserve the right to change details of design, materials and finish. | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| © 2005 Genlyte Group LLC • B0305 |
|