Lytespan®Track Lighting System 6310

Page 2 of 2 Basic Wall Washer

Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC• B1005
Job Information Type:
Lighting Data
TRACK 2 FEET FROM WALL
EXAMPLE:With multiple 75 watt R30 FL
units located 2" from wall, 2" on center
and aimed 60° from horizontal, the illumi-
nation on the wall 3" down from the ceil-
ing is 52 footcandles beneath fixtures and
49 footcandles between fixtures.
Footcandles are average and rounded off
and are based on a minum of five units.
For 100W R30 FL, multiply footcandles by
1.5.
Footcandles on Wall from Multiple Units ñ 75W R30 FL
1" 79 71 79 65 35 65
2" 78 65 78 60 37 60
3" 52 49 52 38 29 38
4" 29 31 29 21 21 21
5" 17 17 17 11 12 11
6" 12 13 12 8 8 8
7" 777 454
8" 555 333
9" 454 333
Distance From Ceiling
2" 2" 3"
60°
TRACK 3 FEET FROM WALL
1" 34 32 34 29 17 29
2" 36 30 36 29 25 29
3" 34 26 34 27 21 27
4" 24 22 24 19 17 19
5" 17 16 17 14 11 14
6" 11 10 11 8 7 8
7" 888 555
8" 565 454
9" 565 434
Distance From Ceiling
3" 3" 4"
60°
2' 2'
3'
49 f.c.
52 f.c.