| Calculite® Incandescent Surface Cylinder | 7026AO | |||||||||||||
Page 2 of 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 9” Aperture | BR40 / R40 / PAR38 | |||||
100 |
|
|
|
|
| Clear Alzak with 250W PAR38 FL, T.H. |
| 80 |
|
|
|
| Clear Alzak with 120W BR40 FL |
| |||||||||
FOOTCANDLES | 90 |
|
|
|
|
| 3600 Lumens Per Lamp |
|
| FOOTCANDLES | 70 |
|
|
|
| 1600 Lumens Per Lamp |
|
| |||||
|
|
|
|
| RCR = 1 (60' x 60' x 8.5' room) |
|
|
|
|
| RCR = 1 (60' x 60' x 8.5' room) |
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
80 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
| RCR = 5 (12' x 12' x 8.5' room) |
| 60 |
|
|
|
| RCR = 5 (12' x 12' x 8.5' room) |
|
| |||||||||
70 |
|
|
|
|
| RCR = 10(6' x 6' x 8.5' room) |
|
|
|
|
| RCR = 10(6' x 6' x 8.5' room) |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
| Room Surface Reflectances: |
|
|
|
|
|
| Room Surface Reflectances: |
|
| |||||||||
60 |
|
|
|
|
|
| 50 |
|
|
|
|
|
| ||||||||||
|
|
|
|
| 80% Ceiling; 50% Walls; 20% Floor |
|
|
|
| 80% Ceiling; 50% Walls; 20% Floor |
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
50 |
|
|
|
|
|
|
|
|
|
|
| 40 |
|
|
|
|
|
|
|
|
| ||
40 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
INITIAL |
|
|
|
|
|
|
|
|
|
|
| INITIAL | 30 |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
30 |
|
|
|
|
|
|
|
|
|
|
| 20 |
|
|
|
|
|
|
|
|
| ||
20 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 10 |
|
|
|
|
|
|
|
|
|
|
|
| 10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 25 |
| 50 |
| 75 | 100 | 125 | 150 | 175 | 200 | 225 |
|
|
| 20 |
| 40 | 60 | 80 | 100 | 120 |
|
|
|
|
| AREA PER FIXTURE IN SQUARE FEET |
|
|
|
|
| AREA PER FIXTURE IN SQUARE FEET |
|
| |||||||||||
| 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |
| 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
|
|
| CENTER TO CENTER DISTANCE OF FIXTURES IN FEET |
|
| CENTER TO CENTER DISTANCE OF FIXTURES IN FEET |
Use quick calculator chart to determine spacing of luminaires for desired level of illumination.
Conversion Factors:
100W PAR38 FL IR, F.C. X 0.6
120W PAR38 FL, F.C. X 0.5
90W PAR38 FL, F.C. X 0.4
75W & 65W IR PAR38 FL, F.C. X 0.3
Use quick calculator chart to determine spacing of luminaires for desired
level of illumination. Conversion Factors:
300W R40 FL, F.C. X 2.2
90W BR40 FL, F.C. X 0.7
75W BR40 FL, F.C. X 0.5
SPACING RATIO = 0.4 | SPACING RATIO = 0.5 |
CERTIFIED TEST REPORT NO. 0870FR
COMPUTED BY LSI PROGRAM
SURFACE CYLINDER OPEN DOWNLIGHT
8” DIA. APERTURE, SPECULAR CLEAR FINISH REFLECTOR 250W PAR38 FL (KRYPTON) PHILIPS LAMP. LUMEN RATING = 3100 LMS.
CANDLEPOWER SUMMARYANGLE | MEAN CP | LUMENS |
0 | 12498 |
|
5 | 11063 | 1009 |
10 | 7681 |
|
15 | 4689 | 1319 |
20 | 2148 |
|
25 | 677 | 416 |
30 | 88 |
|
35 | 18 | 21 |
40 | 9 |
|
45 | 0 | 2 |
50 | 0 |
|
55 | 0 | 0 |
60 | 0 |
|
65 | 0 | 0 |
70 | 0 |
|
75 | 0 | 0 |
80 | 0 |
|
85 | 0 | 0 |
90 | 0 |
|
ZONAL LUMENS AND PERCENTAGES
| ZONE | LUMENS | % LAMP | % LUMINAIRE |
DATE: JUL 30, 1999 | 2743 | 88.50 | 99.17 | |
2764 | 89.18 | 99.93 | ||
PREPARED FOR: | 2766 | 89.24 | 100.00 | |
LIGHOLIER, FALL RIVER, MA | 2766 | 89.24 | 100.00 | |
TESTED ACCORDING TO IES PROCEDURES. | 1 | .06 | .07 | |
0 | .00 | .00 | ||
TEST DISTANCE EXCEEDS FIVE TIMES THE | 0 | .00 | .00 | |
GREATEST LUMINOUS OPENING OF | 2766 | 89.24 | 100.00 |
LUMINAIRE.** EFFICIENCY = 89.2% **
|
|
|
|
|
|
| COEFFICIENTS OF UTILIZATION |
|
|
|
|
|
| |||||||
|
|
|
|
|
| %EFFECTIVE CEILING CAVITY REFLECTANCE |
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
| 80 |
|
|
| 70 |
|
| 50 |
|
| 30 |
|
|
| 10 |
| 0 |
|
|
| 50 | 30 | 10 |
|
|
| % WALL REFLECTANCE |
|
|
| 50 | 30 | 10 | 0 | ||||
|
|
|
| 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 |
| |||||||
| 1 |
| 1.02 | 1.01 | .99 | 1.00 | .99 | .98 | .96 | .96 | .95 | .93 | .93 | .92 | .90 | .90 | .89 | .88 | ||
RATIO | 2 |
| .98 | .96 | .94 | .97 | .92 | .93 | .94 | .93 | .91 | .92 | .91 | .90 | .89 | .89 | .88 | .87 | ||
3 |
| .95 | .93 | .91 | .94 | .92 | .91 | .93 | .91 | .89 | .91 | .89 | .88 | .89 | .88 | .87 | .86 | |||
CAVITY | 4 |
| .93 | .91 | .89 | .92 | .90 | .88 | .91 | .89 | .87 | .89 | .87 | .86 | .88 | .86 | .85 | .84 | ||
6 |
| .89 | .86 | .85 | .89 | .86 | .84 | .88 | .85 | .84 | .87 | .85 | .83 | .86 | .84 | .83 | .82 | |||
ROOM | 5 |
| .91 | .88 | .86 | .90 | .87 | .86 | .89 | .87 | .85 | .88 | .86 | .84 | .86 | .85 | .84 | .83 | ||
7 |
| .87 | .85 | .83 | .87 | .84 | .82 | .86 | .84 | .82 | .82 | .83 | .81 | .84 | .83 | .81 | .81 | |||
| 8 |
| .86 | .83 | .81 | .82. .83 | .81 | .84 | .82 | .81 | .84 | .82 | .81 | .84 | .82 | .80 | .79 | |||
| 9 |
| .84 | .82 | .80 | .84 | .81. | 80 | .83 | .81 | .79 | .83 | .80 | .79 | .82 | .80 | .79 | .78 | ||
| 10 |
| .82 | .80 | .78 | .82 | .80 | .78 | .82 | .79 | .78 | .81 | .79 | .78 | .81 | .79 | .77 | .77 | ||
|
| |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
20% FLOOR CAVITY REFLECTANCE Conversion Factor: 45W to 250W PAR38 FL, C.U. x 1.0
|
| CERTIFIED TEST REPORT NO.0869FR |
|
| |||
|
| COMPUTED BY LSI PROGRAM |
| ||||
|
| SURFACE CYLINDER DOWNLIGHT |
|
| |||
|
| 8” DIA. APERTURE, SPECULAR CLEAR FINISH REFLECTOR |
| ||||
|
| 120W BR40 FL GE LAMP. LUMEN RATING = 1600 LMS |
| ||||
|
|
| CANDLEPOWER SUMMARY | ||||
|
|
| ANGLE | MEAN CP | LUMENS | ||
|
|
| 0 | 3418 |
|
| |
|
|
| 5 | 2993 |
| 280 | |
|
|
| 10 | 2325 |
|
| |
|
|
| 15 | 1771 |
| 508 | |
|
|
| 20 | 1295 |
|
| |
|
|
| 25 | 791 |
| 381 | |
|
|
| 30 | 413 |
|
| |
|
|
| 35 | 134 |
| 150 | |
|
|
| 40 | 72 |
|
| |
|
|
| 45 | 0 |
| 14 | |
|
|
| 50 | 0 |
|
| |
|
|
| 55 | 0 |
| 0 | |
|
|
| 60 | 0 |
|
| |
|
|
| 65 | 0 |
| 0 | |
|
|
| 70 | 0 |
|
| |
|
|
| 75 | 0 |
| 0 | |
|
|
| 80 | 0 |
|
| |
|
|
| 85 | 0 |
| 0 | |
|
|
| 90 | 0 |
|
| |
|
|
| ZONAL LUMENS AND PERCENTAGES | ||||
|
|
| |||||
DATE: JUL 30, 1999 | ZONE | LUMENS | % LAMP | % LUMINAIRE | |||
1167 | 73.00 | 87.70 | |||||
PREPARED FOR: | 1317 | 82.35 | 98.95 | ||||
LIGHOLIER, FALL RIVER, MA | 1331 | 83.23 | 100.00 | ||||
1331 | 83.23 | 100.00 | |||||
|
|
| |||||
TESTED ACCORDING TO IES PROCEDURES. | 14 | .88 | 1.05 | ||||
0 | .00 | .00 | |||||
TEST DISTANCE EXCEEDS FIVE TIMES THE | 0 | .00 | .00 | ||||
GREATEST LUMINOUS OPENING OF | 1331 | 83.23 | 100.00 | ||||
LUMINAIRE. |
| ** EFFICIENCY = 83.28% ** |
|
|
|
|
|
|
|
| COEFFICIENTS OF UTILIZATION |
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
| %EFFECTIVE CEILING CAVITY REFLECTANCE |
|
|
|
|
|
| ||||||||||||
|
|
|
| 80 |
|
|
|
| 70 |
|
|
| 50 |
|
|
|
| 30 |
|
|
| 10 |
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
| 50 | 30 | 10 |
|
|
|
| % WALL REFLECTANCE |
|
|
| 50 | 30 | 10 |
|
|
| |||||||
|
|
|
|
| 50 | 30 | 10 |
| 50 | 30 |
| 10 |
| 50 | 30 | 10 |
|
|
|
| ||||||
|
| 1 | .94 | .93 | .91 |
| .93 | .91 | .90 |
| .89 | .88 |
| .87 |
| .86 | .85 | .85 | .83 | .83 | .82 | 0 |
|
| ||
RATIO | 2 | .90 | .88 | .86 |
| .89 | .87 | .85 |
| .86 | .85 |
| .83 |
| .84 | .83 | .81 | .82 | .81 | .80 | .81 |
|
| |||
3 | .87 | .84 | .82 |
| .86 | .83 | .81 |
| .84 | .82 |
| .80 |
| .82 | .80 | .79 | .80 | .79 | .78 | .79 |
|
| ||||
CAVITY | 4 | .84 | .81 | .78 |
| .83 | .80 | .78 |
| .81 | .79 |
| .77 |
| .80 | .76 | .76 | .78 | .77 | .75 | .76 |
|
| |||
6 | .78 | .75 | .72 |
| .77 | .74 | .72 |
| .76 | .74 |
| .72 |
| .75 | .73 | .71 | .74 | .72 | .71 | .72 |
|
| ||||
|
| 5 | .80 | .77 | .75 |
| .80 | .77 | .74 |
| .78 | .76 |
| .74 |
| .77 | .75 | .73 | .76 | .74 | .73 | .74 |
|
| ||
ROOM | 7 | .75 | .72 | .69 |
| .75 | .72 | .69 |
| .74 | .71 |
| .69 |
| .73 | .70 | .68 | .72 | .70 | .68 | .70 |
|
| |||
8 | .73 | .69 | .67 |
| .72 | .69 | .67 |
| .71 | .69 |
| .67 |
| .71 | .68 | .66 | .70 | .68 | .66 | .67 |
|
| ||||
|
| 9 | .70 | .67 | 64 |
| .70 | .67 | .64 |
| .69 | .66 |
| .64 |
| .69 | .66 | .64 | .68 | .65 | .64 | .65 |
|
| ||
|
| 10 | .68 | .65 | .62 |
| .68 | .65 | .62 |
| .67 | .64 |
| .62 |
| .67 | .64 | .62 | .66 | .64 | .62 | .63 |
|
| ||
|
|
|
|
|
|
|
|
|
| 20% | FLOOR CAVITY REFLECTANCE |
|
|
|
|
| .61 |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| Conversion Factor: |
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
| 65W to 120W BR40FL, C.U. x 1.0; 300W R40FL, C.U. x .95 |
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
| Job Information |
|
|
| Type: |
|
|
|
|
|
|
|
| ||||||||||||
|
| Lightolier a Genlyte Thomas Company |
|
|
|
|
|
| www.lightolier.com | |||||||||||||||||
|
| 631 Airport Road, Fall River, MA 02720 • (508) | ||||||||||||||||||||||||
|
| We reserve the right to change details of design, materials and finish. |
|
|
| |||||||||||||||||||||
|
| © 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902 |
|
|
|
|