26W Fresnel Lens

Quick Calculator

60

 

 

 

ROOM SURFACE REFLECTANCES:

 

 

 

 

80% Ceiling; 50% Wall, 20% Floor

50

 

 

 

1800 Lumens Per Lamp

 

 

 

 

 

 

 

RCR= 1 (Rm. Width = 10xMtg. Ht. above work plane)

40

 

 

 

RCR= 5 (Rm. Width = 2xMtg. Ht. above work plane)

 

 

 

 

RCR=10 (Rm. Width = Mtg. Ht. above work plane)

30

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

40

60

80

100

120

140

 

 

 

AREA PER FIXTURE IN SQUARE FEET

 

4

5

6

7

8

9

10

11

12

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

This quick calculator chart determines the number and spacing of 2 Lt. 26 watt Quad Tube units with Fresnel Lens and clear cone, for any level of illumination.

Conversion Factors: 26W, Fresnel Lens with White Cone = F.C.x 0.9; 18W, Fresnel/Clear Cone = 0.8; 18W Fresnel/Clear Cone =0.7.

Spacing Ratio = 1.2

Certified Test Report Number: 2550

COMPUTED BY: LSI PROGRAM “TEST-LITE”

PREPARED FOR: LIGHTOLIER INC.

APERTURE: 7 1/4”

REFLECTOR: SPECULAR CLEAR ALZAK CONE WITH REGRESSED FRESNEL LENS

LAMPS: TWO 26W QUAD TUBE LENS EACH RATED AT 1800 LUMINES.

 

 

 

CANDELPOWER SUMMARY

 

ACROSS

 

Angle

ALONG

22.5

45

67.5

ACROSS LUMENS

45

 

0

864

864

864

864

864

 

ALONG

 

5

852

850

851

868

875

82

 

10

836

842

860

887

897

 

 

 

 

 

 

15

806

818

849

881

888

238

 

90

20

750

774

812

835

842

 

 

 

25

670

703

743

769

771

336

 

 

30

572

602

643

670

677

 

 

 

35

453

495

533

556

556

328

 

 

40

350

388

416

433

438

 

300

 

45

255

284

312

321

322

241

60

50

207

222

240

249

249

 

 

 

55

70

82

93

103

105

102

 

 

60

29

31

38

42

41

 

 

 

65

8

9

12

10

10

15

 

 

70

3

3

6

3

3

 

600

 

75

2

2

3

2

2

3

 

 

80

1

1

4

2

1

 

 

 

85

1

2

5

3

2

4

 

 

90

2

9

14

6

2

 

900

 

 

ZONAL LUMENS AND PERCENTAGES

 

Zone

Lumens

% Lamp

% Luminaire

0

 

30

0–30

 

657

18.25

 

48.66

 

0–40

 

985

27.37

 

72.97

 

 

 

 

**EFFICIENCY = 37.5%**

 

0–60

1328

36.90

 

98.37

 

 

0–90

1350

37.50

 

100.00

 

 

40–90

 

364

10.14

 

27.03

DATE: NOVEMBER 18, 1992

 

60–90

 

21

.61

 

 

1.63

 

90–180

 

0

.00

 

 

.00

 

 

 

 

 

 

 

0–180

1350

37.50

 

100.00

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES

THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

Coefficients of Utilization

 

 

 

 

 

 

% Effective Ceiling Cavity Reflectance

 

 

 

 

 

 

 

 

 

80

 

 

70

 

 

50

 

 

 

30

 

 

10

 

0

 

 

 

 

 

 

 

 

%Wall Reflectance

 

 

 

 

 

 

 

 

 

 

 

50

30

10

50

30

10

 

30

10

 

50

30

10

50

30

10

0

 

 

 

50

 

RATIO

1

.41

.40

.39

.41

.40

.39

.39

.38

.38

 

.38

.37

.36

.36

.36

.35

.35

3

.35

.33

.32

.35

.33

.32

.34

.32

.31

 

.33

.32

.31

.32

.31

.30

.30

 

 

2

.38

.37

.35

.38

.36

.35

.38

.35

.34

 

.35

.34

.34

.34

.34

.33

.32

CAVITY

4

.33

.31

.29

.32

.31

.29

.32

.30

.29

 

.31

.29

.28

.30

.29

.28

.27

5

.30

.28

.26

.30

.28

.26

.29

.27

.26

 

.29

.27

.25

.28

.27

.25

.25

ROOM

6

.28

.26

.24

.28

.26

.24

.27

.25

.24

 

.27

.25

.24

.26

.25

.23

.23

7

.26

.23

.22

.26

.23

.22

.25

.23

.22

 

.25

.23

.21

.24

.23

.21

.21

 

 

 

 

 

8

.24

.21

.20

.24

.21

.20

.23

.21

.20

 

.23

.21

.19

.22

.21

.19

.19

 

 

9

.22

.20

.18

.22

.20

.18

.21

.19

.18

 

.21

.19

.18

.21

.19

.18

.17

 

 

10

.20

.18

.16

.20

.18

.16

.20

.18

.16

 

.20

.18

.16

.19

.17

.16

.16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20% FLOOR CAVITY REFLECTANCE

Conversion Factors: 26W, Fresnel Lens with White Cone: C.U. x 0.9; 18W, Fresnel/Clear Cone = 1.1; 18W, Fresnel/White Cone = 1.0.

Calculite® CFL Lensed Downlight 8096

7" Aperture (2) Quad Tube Horizontal Lamp

26W Opal Diffuser and Clear Lens

Quick Calculator

FOOTCANDLES

60

 

 

 

 

 

 

 

ROOM SURFACE REFLECTANCES:

 

 

 

 

 

 

 

 

 

 

80% Ceiling; 50% Wall, 20% Floor

 

 

 

50

 

 

 

 

 

 

 

1800 Lumens Per Lamp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCR= 1 (Rm. Width = 10xMtg. Ht. above work plane)

 

40

 

 

 

 

 

 

 

RCR= 5 (Rm. Width = 2xMtg. Ht. above work plane)

 

 

 

 

 

 

 

 

 

RCR=10 (Rm. Width = Mtg. Ht. above work plane)

INITIAL

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

30

45

 

60

75

90

105

120

 

 

 

 

 

 

 

AREA PER FIXTURE IN SQUARE FEET

 

 

 

 

 

4

5

 

6

 

7

8

9

 

 

10

 

11

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

This quick calculator chart determines the number and spacing of 2 lt.-26 watt Quad

Tube units with Opal Diffuser and Clear Cone for any level of illumination.

Conversion Factors: Opal Diffuser/White Cone = F.C. x 0.9. Clear Lens/Clear Cone = F.C. x 1.2.

Clear Lens/White Cone = F.C. x 1.1; 18W, Opal Diffuser/Clear Lens = 0.8; Opal Diffuser/White

Cone = 0.7; Clear Lens/Clear Cone = 0.9; Clear Lens/White Cone = 0.8.

Spacing Ratio = 1.2

Certified Test Report Number: 2551

COMPUTED BY: LSI PROGRAM “TEST-LITE”

PREPARED FOR: LIGHTOLIER INC.

APERTURE: 7 1/4”

REFLECTOR: SPECULAR CLEAR WITH REGRESSED OPAL DIFFUSER

LAMPS: TWO 26W QUAD TUBE EACH RATED AT 1800 LUMINES.

 

 

 

CANDELPOWER SUMMARY

 

ACROSS

 

Angle

Along

22.5

45

67.5

Across

Lumens

45

 

0

634

634

634

634

634

 

ALONG

 

5

622

622

634

643

622

60

 

10

613

613

625

635

615

 

 

 

 

 

 

15

594

595

608

620

601

171

 

90

20

565

567

582

594

576

 

 

25

529

532

549

562

543

251

 

 

 

 

30

482

486

503

519

504

 

 

 

35

430

433

449

464

454

279

 

 

40

370

374

386

401

392

 

200

 

45

299

302

313

326

319

241

60

50

227

227

234

244

238

 

 

55

87

91

96

104

102

104

 

 

 

 

60

30

32

37

41

40

 

 

 

65

7

8

11

10

9

14

 

 

70

2

3

6

3

3

 

400

 

75

2

2

3

2

1

2

 

80

1

1

4

2

1

 

 

 

 

 

 

85

1

1

4

3

1

4

 

 

90

1

9

14

7

2

 

600

 

 

ZONAL LUMENS AND PERCENTAGES

 

Zone

Lumens

% Lamp

% Luminaire

0

 

30

0–30

 

481

13.38

42.75

 

0–40

 

761

21.15

67.55

 

 

 

**EFFICIENCY = 31.1%**

 

0–60

 

1106

30.73

98.15

 

 

0–90

 

1126

31.30

100.00

 

 

40–90

 

365

10.16

32.45

DATE: NOVEMBER 19, 1992

 

60–90

 

20

.58

 

1.85

 

90–180

 

0

.00

 

 

.00

 

 

 

 

 

 

 

0–180

 

1126

31.30

100.00

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES

THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

Coefficients of Utilization

% Effective Ceiling Cavity Reflectance

 

 

 

80

 

 

70

 

 

50

 

 

 

 

30

 

 

 

10

 

0

 

 

 

 

 

 

 

 

%Wall Reflectance

 

 

 

 

 

 

 

 

 

 

 

 

 

50

30

10

50

30

10

 

30

10

 

50

30

10

 

50

30

10

0

 

 

 

50

 

 

 

RATIO

1

.34

.33

.33

.34

.33

.32

.32

.32

.31

 

.31

.31

.30

 

.30

.30

.29

.29

 

3

.29

.27

.26

.29

.27

.26

.28

.27

.25

 

.27

.26

.25

 

.26

.25

.25

.24

 

 

2

.32

.30

.29

.31

.30

.29

.30

.29

.28

 

.29

.28

.28

 

.28

.28

.27

.26

 

CAVITY

4

.27

.25

.23

.27

.25

.23

.26

.24

.23

 

.25

.24

.23

 

.25

.23

.22

.22

 

6

.23

.21

.19

.22

.20

.19

.22

.20

.19

 

.21

.20

.19

 

.21

.20

.18

.18

 

 

5

.25

.23

.21

.24

.22

.21

.24

.22

.21

 

.23

.22

.21

 

.23

.21

.20

.20

 

ROOM

7

.21

.19

.17

.20

.18

.17

.20

.18

.17

 

.20

.18

.17

 

.19

.18

.17

.16

 

8

.19

.17

.15

.19

.17

.15

.18

.16

.15

 

.18

.16

.15

 

.18

.16

.15

.14

 

 

 

 

 

 

9

.17

.15

.14

.17

.15

.14

.17

.15

.14

 

.17

.15

.13

 

.16

.15

.13

.13

 

 

10

.16

.14

.12

.16

.14

.12

.15

.14

.12

 

.15 .13 .12

 

.15

.13

.12

.12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20% FLOOR CAVITY REFLECTANCE

 

 

 

 

 

 

 

Conversion Factors: 26W, Opal Diffuser/White Cone: C.U. x 0.9. Clear Lens/Clear Cone: C.U. x 1.2. Clear

Lens/White Cone: C.U. x 1.1; Opal Diffuser/Clear Lens = 1.1; Opal Diffuser/White Cone = 1.0; Clear

 

 

Lens/Clear Cone = 1.3; Clear Lens/White Cone = 1.2.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Job Information

 

 

 

Type:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • A0708

Lightolier is a Philips group brand

Page 2
Image 2
Lightolier 8096 Calculite CFL Lensed Downlight, Page 2 of, Lightolier is a Philips group brand, Job Information, Type