Lightolier 8120 Page 2 of, Cylinder Flood 34 Mini HID 39W T4.5 CMH Lamp, Lighting Data, Type

Models: 8120

1 2
Download 2 pages 50.18 Kb
Page 2
Image 2
Lytespan® Track Lighting System  8120

Lytespan® Track Lighting System  8120

Page 2 of 2

Lighting Data

 

Aiming Angle

Cylinder Flood 34° Mini HID 39W T4.5 CMH Lamp

30°, 45° or 60° Horizontal 30°, 45° or 60° Vertical

LBeam Length

W Beam Width

CDistance to center beam

DDistance

A

Aiming Angle

 

FC

Footcandles

D

 

 

L and W are the outer points where the candle

 

power drops to 50% of the maximum. FC are the

 

initial footcandles at the center of the beam.

 

 

L

FC

 

 

W

D

A

FC

W

L Page 2 of 2 C

D

A

C

FC L

Lamp

 

 

 

0° Aiming Angle

A=30° Aiming Angle

 

A=45° Aiming Angle

A=60° Aiming Angle

Beam Spread

Beam Center

Rated

 

D

FC

L

W

D

C

FC

L

W

 

D

C

FC

L

W

D

C

FC

L

W

50% Max CP

C.P. Candelas

Life-Hrs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6'

114

3.7'

3.7'

 

6'

3.5'

74

5.0'

4.2'

3'

3.0'

161

4.0'

2.6'

 

2'

3.5'

128

6.8'

2.4'

 

 

 

8'

64

4.9'

4.9'

 

8'

4.6'

41

6.7'

5.6'

4'

4.0'

90

5.4'

3.5'

 

3'

5.2'

57

10.2'

3.7'

CMH 39T4/G8.5

4087

9,000

10'

41

6.1'

6.1'

 

10'

5.8'

27

8.4'

7.1'

5'

5.0'

58

6.7'

4.3'

 

4'

6.9'

32

13.6'

4.9'

34°

 

 

12'

28

7.3'

7.3'

 

12'

6.9'

18

10.1'

8.5'

6'

6.0'

40

8.1'

5.2'

 

5'

8.7'

20

17.0'

6.1'