Lightolier manual MHT6RF, MHT6RNF, MHT6RS, Page 2 of, Lytespan Track Lighting8121

Models: 8121

1 2
Download 2 pages 58.09 Kb
Page 2
Image 2
Lytespan® Track Lighting  8121

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lytespan® Track Lighting  8121

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 2 of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mini HID Cylinder 39W T6 CMH (M130)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MHT6RF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Metal Halide T-6 Reflector Flood

Aiming Angle:

L Beam Length

D

Distance

W Beam Width

A

Aiming Angle

C Distance to center beam

FC

Footcandles

L and W are the outer points where the candle power drops to 50% of the maximum. FC are the initial footcandles at the center of the beam.

Lamp data shown is typical. Consult lamp manu- facturers for availability and performance.

CBCP = Center Beam Candle Power.

Flood Reflector

30° Horizontal

30° Vertical

45° Vertical

with 39W T-6 Master Color Ceramic Metal Halide Philips (Clear) Lamp

Lamp

(To 50% CBCP)

 

Life (Hrs.)

 

D

FC

L

W

 

Beam Spread

CBCP

Rated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6'

107

4.4'

4.4'

 

 

 

 

8'

60

5.8'

5.8'

 

 

3,849

9000

10'

38

7.3'

7.3'

39W T-6

 

 

to

12'

27

8.7'

8.7'

 

40°

 

15,000

 

 

 

 

 

D

C

FC

L

W

 

 

 

 

 

6'

3.5'

69

6.1'

5.0'

8'

4.6'

39

8.1'

6.7'

10'

5.8'

25

10.2'

8.4'

12'

6.9'

17

12.2'

10.1'

D

C

FC

L

W

 

 

 

 

 

2'

3.5'

120

9.7'

2.9'

3'

5.2'

53

14.5'

4.4'

4'

6.9'

30

19.3'

5.8'

5'

8.7'

19

24.2'

7.3'

D

C

FC

L

W

 

 

 

 

 

3'

3.0'

151

5.0'

3.1'

4'

4.0'

85

6.7'

4.1'

5'

5.0'

54

8.4'

5.1'

6'

6.0'

38

10.1'

6.2'

MHT6RNF

Metal Halide T-6 Narrow Flood

Aiming Angle:

L Beam Length

D

Distance

W Beam Width

A

Aiming Angle

C Distance to center beam

FC

Footcandles

L and W are the outer points where the candle power drops to 50% of the maximum. FC are the initial footcandles at the center of the beam.

Lamp data shown is typical. Consult lamp manu- facturers for availability and performance.

CBCP = Center Beam Candle Power.

Narrow Flood Reflector

30° Horizontal

30° Vertical

45° Vertical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with 39W T-6 Master Color Ceramic Metal Halide Philips (Clear) Lamp

Lamp

(To 50% CBCP)

 

Life (Hrs.)

 

D

FC

L

W

 

 

Beam Spread

CBCP

Rated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6'

171

3.0'

3.0'

 

 

 

 

 

8'

109

3.7'

3.7'

 

 

 

10,932

12,000

10'

76

4.4'

4.4'

 

 

 

 

 

12'

56

5.2'

5.2'

 

 

21°

 

 

 

 

 

 

 

D

C

FC

L

W

 

 

 

 

 

6'

4.5'

111

4.0'

5.0'

8'

5.8'

71

5.0'

6.7'

10'

6.9'

49

6.0'

8.4'

12'

8.1'

36

7.0'

10.1'

D

C

FC

L

W

 

D

C

FC

L

W

 

 

 

 

 

 

 

 

 

 

 

2'

5.2'

152

5.0'

2.2'

 

5'

5.0'

155

3.8'

2.6'

3'

6.9'

85

6.6'

3.0'

6'

6.0'

107

4.6'

3.1'

4'

8.7'

55

8.3'

3.7'

7'

7.0'

79

5.4'

3.7'

5'

10.4'

38

9.9'

4.4'

8'

8.0'

60

6.1'

4.2'

MHT6RS

Metal Halide T-6 Reflector Spot

Aiming Angle:

L Beam Length

D

Distance

W Beam Width

A

Aiming Angle

C Distance to center beam

FC

Footcandles

L and W are the outer points where the candle power drops to 50% of the maximum. FC are the initial footcandles at the center of the beam.

Lamp data shown is typical. Consult lamp manu- facturers for availability and performance.

CBCP = Center Beam Candle Power.

Spot Reflector

30° Horizontal

30° Vertical

45° Vertical

with 39W T6 Master Color Ceramic Metal Halide Philips (Clear) Lamp

Lamp

(To 50% CBCP)

 

Life (Hrs.)

 

D

FC

L

W

 

Beam Spread

CBCP

Rated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10'

281

1.7'

1.7'

 

 

 

 

15'

125

2.6'

2.6'

 

 

28,105

9,000

20'

70

3.5'

3.5'

39W T6 CMH

10°

 

12,000

25'

45

4.4'

4.4'

 

 

 

 

 

 

 

D

C

FC

L

W

 

 

 

 

 

6'

4.6'

285

1.9'

1.6'

12'

6.9'

127

2.8'

2.4'

16'

9.2'

71

3.7'

3.2'

20'

11.5'

46

4.7'

4.0'

D

C

FC

L

W

 

 

 

 

 

4'

6.9'

220

2.9'

1.4'

6'

10.4'

98

4.3'

2.1'

8'

13.9'

55

5.7'

2.8'

10'

17.3'

35

7.2'

3.5'

D

C

FC

L

W

 

 

 

 

 

6'

6.0'

276

2.1'

1.5'

9'

9.0'

123

3.2'

2.2'

12'

12.0'

69

4.2'

3.0'

15'

15.0'

44

5.3'

3.7'

Job Information

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2009 Philips Group • B0109

Lightolier is a Philips group brand

Page 2
Image 2
Lightolier manual MHT6RF, MHT6RNF, MHT6RS, Page 2 of, Lytespan Track Lighting8121, Mini HID Cylinder 39W T6 CMH M130