| Lytespan® Track Lighting System 9376 |
Page 2 of 2 | PowerWash™ T5 3 Foot Track Mounted 39 Watt High Output Fluorescent |
Lighting Data 2-39W T5 High Output
Footcandles on wall:
Lamp Information:
2 X 39W T5 High Output
Mini
1 x 39W T5 High Output
Mini Bi Pin Fluorescent (9377)
Two Lamps, without louver, aimed 45˚ up.
Two Lamps, with louver, aimed 45˚ down.
180˚ 150˚
120˚
90˚
90˚
60˚
0˚ 30˚
EXAMPLE: With track located 4’ from wall and multiple units |
spaced 6’ on center and aimed 45˚ from horizontal, the illumination |
One Lamp, with louver, aimed 45˚ down.
90˚
60˚
on wall 4’ from ceiling will be 57 f.c. beneath units and 48 f.c. | Footcandles on Wall |
between units. |
0˚ 30˚
Track 3 Feet From Wall | Single Unit |
Multiple Units
|
|
|
|
|
|
|
|
|
| 0’ | 1’ | 2’ | 3’ | 4’ | 5’ |
|
| |
|
|
|
|
|
| 3’ |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| Beam Center |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ceiling | 1’ |
|
|
|
| 157 | 132 | 76 | 36 | 17 | 9 |
|
| |||||
2’ |
|
| 45˚ |
| 123 | 106 | 65 | 32 | 14 | 6 |
|
| ||||||
3’ |
|
|
|
|
| 78 | 69 | 47 | 27 | 13 | 6 |
|
| |||||
|
|
|
|
|
|
| ||||||||||||
From |
|
|
|
|
|
| ||||||||||||
4’ |
|
|
|
| 51 | 46 | 34 | 22 | 13 | 7 |
|
| ||||||
Distance | 5’ |
|
|
|
| 30 | 27 | 21 | 15 | 9 | 6 |
|
| |||||
6’ |
|
|
|
| 19 | 18 | 15 | 11 | 8 | 5 |
|
| ||||||
7’ |
|
|
|
|
| 12 | 12 | 10 | 8 | 6 | 4 |
|
| |||||
|
|
|
|
|
|
| ||||||||||||
| 8’ |
|
|
|
| 8 | 8 | 7 | 5 | 4 | 3 |
|
| |||||
| 9’ |
|
|
|
| 6 | 6 | 5 | 4 | 3 | 3 |
|
|
4’
196 | 166 | 196 |
153 | 136 | 153 |
107 | 100 | 107 |
83 | 80 | 83 |
50 | 49 | 50 |
40 | 39 | 40 |
27 | 27 | 27 |
19 | 19 | 19 |
16 | 16 | 16 |
5’
178 | 114 | 178 |
136 | 95 | 136 |
91 | 74 | 91 |
70 | 62 | 70 |
41 | 38 | 41 |
33 | 32 | 33 |
22 | 21 | 22 |
15 | 15 | 15 |
13 | 13 | 13 |
6’
17077 170
12965 129
84 | 54 | 84 |
63 | 50 | 63 |
35 | 30 | 36 |
29 | 26 | 29 |
19 | 18 | 19 |
13 | 13 | 13 |
11 | 11 | 11 |
Track 4 Feet From Wall | Single Unit |
Multiple Units
4’ |
|
| 0’ | 1’ | 2’ | 3’ | 4’ | 5’ |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Beam Center |
|
|
| |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
Ceiling | 1’ |
| 87 | 75 | 48 | 24 | 10 | 3 | ||
2’ | 45˚ | 86 | 76 | 53 | 31 | 16 | 7 | |||
From | 3’ |
| 65 | 58 | 43 | 27 | 15 | 8 | ||
| ||||||||||
4’ |
| 47 | 43 | 33 | 23 | 15 | 9 | |||
Distance | 5’ |
| 34 | 32 | 26 | 19 | 13 | 9 | ||
|
| |||||||||
| 6’ |
| 23 | 21 | 18 | 14 | 10 | 7 | ||
| 7’ |
| 16 | 15 | 13 | 10 | 8 | 6 | ||
| 8’ |
| 11 | 11 | 9 | 8 | 6 | 5 | ||
| 9’ |
| 8 | 8 | 7 | 6 | 5 | 4 |
4’ |
10597 105
117111 117
96 | 93 | 96 |
79 | 77 | 79 |
66 | 64 | 66 |
47 | 46 | 47 |
35 | 35 | 35 |
29 | 29 | 29 |
22 | 22 | 22 |
5’
92 | 69 | 92 |
100 | 82 | 100 |
80 | 70 | 80 |
65 | 60 | 65 |
54 | 51 | 54 |
38 | 37 | 38 |
29 | 28 | 29 |
24 | 24 | 24 |
18 | 18 | 18 |
6’
87 | 48 | 87 |
| |||
92 | 60 | 92 |
| |||
71 | 53 | 71 |
| |||
| 57 |
| 48 |
| 57 |
|
47 | 42 | 47 |
| |||
33 | 30 | 33 |
| |||
25 | 23 | 25 |
| |||
21 | 20 | 21 |
| |||
16 | 15 | 16 |
|
Track 5 Feet From Wall |
|
| Single Unit |
|
| |||
|
| 5’ | 0’ | 1’ | 2’ | 3’ | 4’ | 5’ |
|
|
|
| Beam Center |
|
|
| |
Ceiling | 1’ |
| 61 | 55 | 41 | 27 | 16 | 10 |
2’ | 45˚ | 62 | 56 | 43 | 29 | 18 | 11 | |
3’ |
| 55 | 51 | 40 | 28 | 18 | 12 | |
From |
| |||||||
4’ |
| 40 | 38 | 30 | 22 | 15 | 10 | |
Distance | 5’ |
| 31 | 29 | 24 | 18 | 13 | 9 |
6’ |
| 24 | 22 | 19 | 15 | 12 | 8 | |
7’ |
| 18 | 17 | 15 | 12 | 10 | 7 | |
|
| |||||||
| 8’ |
| 13 | 12 | 11 | 9 | 7 | 6 |
| 9’ |
| 10 | 9 | 8 | 7 | 6 | 5 |
4’
99 | 96 | 99 |
104 | 102 | 104 |
101 | 99 | 101 |
77 | 76 | 77 |
63 | 62 | 63 |
53 | 53 | 53 |
43 | 43 | 43 |
32 | 32 | 32 |
27 | 27 | 27 |
Multiple Units
5’
83 | 74 | 83 |
87 | 80 | 87 |
84 | 79 | 84 |
63 | 60 | 63 |
51 | 49 | 51 |
44 | 42 | 44 |
36 | 35 | 36 |
26 | 26 | 26 |
22 | 22 | 22 |
6’
74 | 58 | 74 |
77 | 63 | 77 |
75 | 64 | 75 |
54 | 49 | 54 |
44 | 41 | 44 |
37 | 35 | 37 |
31 | 29 | 31 |
22 | 22 | 22 |
19 | 19 | 19 |
Footcandles are average and rounded off and data for multiple units are based on a minimum of five units.
Job Information |
| Type: |
Lightolier a Genlyte Thomas Company | www.lightolier.com |
631 Airport Road, Fall River, MA 02720 • (508)
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • B0902