Lightolier AGM Page 4 of, Distribution, lamp T5 UP, 2 lamp T5 DOWN per 4’ section, Candlepower

Models: AGM

1 4
Download 4 pages 19.56 Kb
Page 4
Image 4
Page 4 of 4

Lighting Systems Agili-T Pendant Direct/Indirect AGM

Page 4 of 4

1 lamp T5 UP, 2 lamp T5 DOWN per 4’ section

Performance

CANDLEPOWER CURVE

DISTRIBUTION

ZONE

LUMENS

%LAMP

% LUMINAIRE

0-30

1243

15.88

23.97

0-40

1909

24.39

36.81

0-60

2769

35.37

53.40

0-90

2818

36.00

54.35

40-90

909

11.62

17.53

60-90

49

.63

.95

90-180

2367

30.24

45.65

0-180

5186

66.24

100.00

REPORT NO: LSC8534

CAT. NO: AGM4PGRDS328UNVPG

2 x 28W T5 down and 1 x 28W T5 up at 2610 lumens. Efficiency: 66.2%. Indirect Maximum candela: 1067 cd Indirect Peak at: 120°. Candela at Nadir: 1685 cd

CANDLEPOWER

ZONE

 

 

 

 

 

 

DEG

 

0

22,5

45

67,5

90

 

0

1685

1685

1685

1685

1685

5

1676

1674

1682

1688

1685

15

1570

1580

1611

1628

1617

25

1398

1407

1376

1366

1354

35

1154

1144

1071

1021

977

45

857

806

689

623

593

55

420

421

345

311

275

65

5

18

59

45

10

75

0

0

0

0

0

85

0

0

0

0

0

90

0

0

0

0

0

95

7

137

178

196

194

105

47

319

530

640

663

115

101

221

709

958

962

125

155

195

464

777

880

135

206

229

304

452

515

145

250

260

293

331

351

155

289

279

297

323

315

165

312

297

310

315

320

175

316

315

314

321

315

180

322

322

322

322

322

ROOM CAVITY RATIO

COEFFICIENTS OF UTILIZATION

 

 

 

ZONAL CAVITY METHOD • EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

 

 

80

 

 

 

70

 

 

 

50

 

 

 

30

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall reflectance

 

 

 

 

 

 

 

70

50

30

70

70

50

30

10

 

50

30

10

 

50

30

10

50

30

10

0

.72

.72

.72

.72

.66

.66

.66

.66

 

.57

.57

.57

 

.48

.48

.48

.40

.40

.40

1

.67

.64

.62

.60

.62

.60

.58

.56

 

.52

.50

.49

 

.44

.43

.43

.37

.37

.36

2

.62

.58

.55

.52

.58

.54

.51

.49

 

.47

.45

.43

 

.41

.39

.38

.35

.34

.33

3

.57

.52

.48

.45

.53

.49

.45

.43

 

.43

.40

.38

 

.37

.35

.34

.32

.31

.30

4

.53

.47

.43

.39

.50

.44

.40

.37

 

.39

.36

.34

 

.34

.32

.30

.29

.28

.27

5

.49

.42

.38

.34

.46

.40

.36

.33

 

.35

.32

.30

 

.31

.28

.27

.27

.25

.24

6

.46

.38

.34

.30

.43

.36

.32

.29

 

.32

.29

.26

 

.28

.26

.24

.25

.23

.21

7

.42

.35

.30

.27

.39

.33

.29

.26

 

.29

.26

.23

 

.26

.23

.21

.23

.21

.19

8

.39

.32

.27

.24

.37

.30

.26

.23

 

.27

.23

.21

 

.24

.21

.19

.21

.19

.17

9

.36

.29

.24

.21

.34

.27

.23

.20

 

.24

.21

.18

 

.21

.19

.17

.19

.17

.15

10

.34

.26

.21

.18

.31 .25 .21

.18

.22 .19 .16

.20 .17 .15

.17

.15

.13

 

 

 

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS = 94.7

 

 

 

 

0

0

.36

.33

.30

.27

.24

.22

.20

.18

.16

.14

.12

 

 

Job Information

Type:

LIGHTOLIER A GENLYTE COMPANY

www.lightolier.com

CANLYTE

www.canlyte.com

TECHNICAL INFORMATION: (978) 657-7600 - (978) 658-0595

 

525 EDUCATION ROAD, CORNWALL, ONTARIO, CANADA K6H 6C7 - (613) 938-6221

631 AIRPORT ROAD, FALL RIVER, MA 02720 - (508) 679-8131

 

WE RESERVE THE RIGHT TO CHANGE DETAILS OF DESIGN, MATERIALS AND FINISH

 

 

© 2007 GENLYTE GROUP LLC (LIGHTOLIER DIVISION)

Page 4
Image 4
Lightolier AGM Page 4 of, Distribution, lamp T5 UP, 2 lamp T5 DOWN per 4’ section, Candlepower Curve, Job Information