Performance

 

 

 

 

 

 

 

Candlepower Curve

Candlepower Summary

 

 

 







 

 

ZONE

 

CANDLEPOWER

 

 

 

 

 

 

 

 

 

 

DEG.

0

22.5

45

67.5

90

 

 

 



 

 

 

 

 

 

 

 



 

 

180

1045

1045

1045

1045

1045

 

 

 



 

175

1040

1038

1038

1035

1037

 

 

 



165

1001

994

1000

1003

1006

 

 

 



155

931

922

942

949

957

 

 

 



145

831

826

863

906

925

 

 

 

135

693

705

788

855

884

 

 

 

 



125

544

569

700

795

827

 

 

 

 



 

 



115

376

434

596

673

706

 

 

105

205

299

448

501

545

 

 

 

 

 



 

 



95

48

117

187

172

214

 

 

 

 

90

5

20

35

42

47

 

 

 



 

 

 

 

 

85

15

26

42

48

51



 

 



 

 

 

 

 

75

43

46

55

68

73

 

 

 



 



 

 



 

65

86

99

86

72

76

 

 







 

55

185

163

155

131

128

 

 

Report No: 2101580

45

300

249

227

212

212

35

412

354

314

281

286

Lamps: F32T8

25

515

463

437

384

384

Lumens per Lamp: 2950

15

598

567

548

515

516

Efficiency: 82.1%

5

646

637

636

619

623

Up: 76.9% Down: 23.1%

0

651

651

651

651

651

Module Lengths & Mounting Distances

@

-ODULE ,ENGTH ,

-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

Note: Shaded area indicates locations of emergency sections (emergency wiring controls all lamps or optional battery pack controls one or two lamps).

2 Light T8 Direct/Indirect

Coefficients of Utilization

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

80

 

 

70

 

 

 

50

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

50

30

10

50

30

10

 

50

30

10

0

82

82

82

73

73

73

 

56

56

56

1

72

69

66

64

61

59

 

49

47

46

2

63

58

54

56

52

49

 

43

40

38

3

55

50

45

49

45

41

 

38

35

32

4

49

43

38

44

39

35

 

34

30

27

5

44

37

33

39

34

30

 

30

26

24

6

39

33

28

35

30

26

 

27

23

21

7

35

29

25

31

26

22

 

25

21

18

8

32

26

22

29

23

20

 

22

19

16

9

29

23

19

26

21

18

 

20

17

14

10

26

21

17

24

19

16

 

19

15

13

Zonal Lumen Summary

 

ZONE

LUMENS

%BARE LAMP

%LUMINAIRE

0-90

1117

18.9

23.1

90-180

3728

63.2

76.9

0-180

4845

82.1

100.0

Run Configuration

Run

4’

8’

12’

Joiner

End Set

Mount

Power

Length

Module

Module

Module

Mount*

 

 

 

 

 

 

 

 

 

 

 

4’ run

1

 

 

 

1

1

1

 

 

 

 

 

 

 

 

8’ run

 

1

 

 

1

1

1

 

 

 

 

 

 

 

 

12’ run

 

 

1

 

1

1

1

 

 

 

 

 

 

 

 

16’ run

 

2

 

1

1

2

1

 

 

 

 

 

 

 

 

20’ run

 

1

1

1

1

2

1

 

 

 

 

 

 

 

 

24’ run

 

 

2

1

1

2

1

 

 

 

 

 

 

 

 

28’ run

 

2

1

2

1

3

1

 

 

 

 

 

 

 

 

32’ run

 

1

2

2

1

3

1

 

 

 

 

 

 

 

 

*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.

System Components & Accessories

End Set

BSLESW = suspended standard white

Joiner

BSLJS = suspended joiner

Dust Cover

BSLDCS = 4’ suspended dust cover

Job Information

Type:

Lightolier a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Page 2
Image 2
Lightolier Lighting Systems Baselyte-BSL1, Module Lengths & Mounting Distances, Run Configuration, Type, Performance