Lightolier Baselyte-BSL10 Module Lengths & Mounting Distances, Run Configuration, Performance

Models: Baselyte-BSL10

1 4
Download 4 pages 30.57 Kb
Page 2
Image 2
Page

Lighting SystemsBaselyte-BSL10

Page

 

of 4

 

 

 

 

 

 

 

 

 

 

Performance

 

 

 

 

 

 

 

 

 

 

Candlepower Curve

 

 

Candlepower Summary

 

 

 











 

 

 

ZONE

 

CANDLEPOWER

 

 

 

 

 

 

 

 

 

 

 

 

 

DEG.

0

45

90

135

180



 

 

 

 

 

 

 

 

 

 

 



 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



 

 

180

341

341

341

341

341

 

 

 

 

 

 

 



 

175

385

371

339

310

298

 

 

 

 

 

 

 



165

469

426

329

250

231

 

 

 

 

 

 

 



155

554

475

311

211

230

 

 

 

 

 

 

 



145

667

531

284

210

200

 

 

 

 

 

 

 

135

715

584

249

175

148

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



125

744

579

206

125

105

 

 

 



 

 

 



115

556

553

159

81

70

 

 

 

 

 

 

 

 

 

 



 

 

 



105

300

332

101

43

42

 

 

 

 

 

 

95

121

117

31

17

19

 

 

 

 

 

 

 



 

 

 

 



 

 

 

 

90

71

61

2

4

6

 

 

 

 

 

 



 

 

 

 

 

 

 

 

 

85

91

78

12

1

1

 

 

 

 

 

 

 



 

 

 

 



 

 

 

 

75

154

141

40

1

1

 

 

 

 

 



 

 





 

 



 

 

65

270

276

80

3

1





 

 

 

 

 

 

 

 

 

55

456

455

178

28

7

 

 

 

 

 

 

 

 

 

 

Report No: 2101681

 

 

45

659

619

284

38

33

 

 

 

35

812

690

395

29

34

 

Lamps: F54T5

 

 

 

 

 

 

 

 

 

25

813

699

491

117

15

 

Lumens per Lamp: 4650

 

 

 

 

 

15

749

707

572

337

201

 

Efficiency: 62.3%

 

 

 

 

 

 

 

5

679

669

619

563

525

 

Up: 55.1% Down: 44.9%

 

 

0

623

623

623

623

623

Light T5 HO Wall Mount Direct/Indirect

Coefficients of Utilization

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

80

 

 

70

 

 

 

50

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

50

30

10

50

30

10

 

50

30

10

0

66

66

66

60

60

60

 

50

50

50

1

57

55

53

52

50

49

 

44

42

41

2

50

46

43

46

43

40

 

38

36

34

3

44

40

36

40

37

33

 

34

31

29

4

39

34

30

36

32

28

 

30

27

24

5

35

30

26

32

28

24

 

27

24

21

6

31

26

23

29

24

21

 

24

21

18

7

28

23

20

26

22

19

 

22

19

16

8

25

21

17

24

19

16

 

20

17

14

9

23

19

15

22

17

15

 

18

15

13

10

21

17

14

20

16

13

 

17

14

11

Zonal Lumen Summary

 

 

ZONE

LUMENS

%BARE LAMP

%LUMINAIRE

0-90

1300

28.0

44.8

90-180

1599

34.4

55.2

0-180

2899

62.3

100.0

Module Lengths & Mounting Distances

@

-ODULE ,ENGTH ,

-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

Note: Shaded area indicates locations of emergency sections (emergency wiring controls all lamps or optional battery pack controls one or two lamps).

Run Configuration

Run

4’

8’

12’

Joiner

End Set

Mount

Power

Length

Module

Module

Module

Mount*

 

 

 

 

 

 

 

 

 

 

 

4’ run

1

 

 

 

1

1

1

 

 

 

 

 

 

 

 

8’ run

 

1

 

 

1

1

1

 

 

 

 

 

 

 

 

12’ run

 

 

1

 

1

1

1

 

 

 

 

 

 

 

 

16’ run

 

2

 

1

1

2

1

 

 

 

 

 

 

 

 

20’ run

 

1

1

1

1

2

1

 

 

 

 

 

 

 

 

24’ run

 

 

2

1

1

2

1

 

 

 

 

 

 

 

 

28’ run

 

2

1

2

1

3

1

 

 

 

 

 

 

 

 

32’ run

 

1

2

2

1

3

1

 

 

 

 

 

 

 

 

*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.

System Components & Accessories

End Set

BSLEWW = wall mount standard white

Joiner

BSLJW = wall mount joiner

Non-Power Wall Mount

 

Power Wall Mount

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BSLWN = non-power wall mount

BSLWP1 = 1-power mount

 

BSLWP2 = 2-power mount

Job Information

Type:

Lightolier a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Page 2
Image 2
Lightolier Baselyte-BSL10 Module Lengths & Mounting Distances, Run Configuration, System Components & Accessories, Type