Lightolier Lighting Systems Baselyte-BSL13, Performance, Module Lengths & Mounting Distances

Models: Baselyte-BSL13

1 8
Download 8 pages 61.93 Kb
Page 2
Image 2
Lighting Systems  Baselyte-BSL13

Lighting SystemsBaselyte-BSL13

Page

 

of 8

 

 

 

 

 

 

 

Performance

 

 

 

 

 

 

 

Candlepower Curve

Candlepower Summary

 

 

 







 

 

 

ZONE

 

CANDLEPOWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



 

 

DEG.

0

22.5

45

67.5

90

 

 

 

 

 

 

 

 

 

 



 

180

2754

2754

2754

2754

2754

 

 

 

 



 

 

 

 

 

 

175

2741

2743

2747

2747

2749

 

 

 

 

 

 

 

 

 

 



165

2647

2656

2672

2682

2691

 

 

 

 



155

2469

2487

2538

2589

2607

 

 

 

 



145

2213

2243

2349

2420

2442

 

 

 

 

 



135

1880

1944

2081

2157

2189

 

 

 

 



125

1492

1589

1742

1816

1836



 

 

 

115

1061

1178

1316

1305

1312



 

 

 



105

592

715

750

740

752

 

 

 

 

 

95

137

190

221

219

231

 

 

 

 



 

 

 

 

 

 

90

4

12

29

41

48



 

 

 



 

 

 

 

 

 

85

9

13

26

42

48



 

 

 



 

 

 

 



 

75

17

22

41

59

67

 

 

 



 





 

 

65

23

36

58

76

84

 

 

 

 

 

 

 

 

 

55

38

54

75

91

99

Report No: 9900153

45

61

72

88

104

111

35

84

89

103

113

119

Lamps: F32T8

25

104

107

116

122

126

Lumens per Lamp: 2950

15

118

119

122

127

129

Efficiency: 79.6%

5

126

126

126

126

127

Up: 95.5% Down: 4.5%

0

127

127

127

127

127

Module Lengths & Mounting Distances

@

-ODULE ,ENGTH ,

-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

Note: Shaded area indicates locations of emergency sections (emergency wiring controls all lamps or optional battery pack controls one or two lamps).

4 Light T8 Semi-Indirect

Coefficients of Utilization

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

80

 

 

70

 

 

 

50

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

50

30

10

50

30

10

 

50

30

10

0

76

76

76

66

66

66

 

46

46

46

1

66

63

61

57

55

52

 

40

38

37

2

58

53

49

50

46

43

 

35

32

30

3

50

45

41

43

39

35

 

30

28

25

4

44

38

34

38

33

30

 

27

24

21

5

39

33

29

34

29

25

 

24

20

18

6

35

29

25

30

25

21

 

21

18

15

7

31

25

21

27

22

19

 

19

16

13

8

28

22

18

24

19

16

 

17

14

12

9

25

20

16

22

17

14

 

15

12

10

10

23

18

14

20

15

12

 

14

11

9

Zonal Lumen Summary

 

ZONE

LUMENS

%BARE LAMP

%LUMINAIRE

0-90

425.5

3.6

4.5

90-180

8972.5

76.0

95.5

0-180

9398

79.6

100.0

Run Configuration

Run

4’

8’

12’

Joiner

End Set

Mount

Power

Length

Module

Module

Module

Mount*

 

 

 

 

 

 

 

 

 

 

 

4’ run

1

 

 

 

1

1

1

 

 

 

 

 

 

 

 

8’ run

 

1

 

 

1

1

1

 

 

 

 

 

 

 

 

12’ run

 

 

1

 

1

1

1

 

 

 

 

 

 

 

 

16’ run

 

2

 

1

1

2

1

 

 

 

 

 

 

 

 

20’ run

 

1

1

1

1

2

1

 

 

 

 

 

 

 

 

24’ run

 

 

2

1

1

2

1

 

 

 

 

 

 

 

 

28’ run

 

2

1

2

1

3

1

 

 

 

 

 

 

 

 

32’ run

 

1

2

2

1

3

1

 

 

 

 

 

 

 

 

*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.

System Components & Accessories

End Set

BSLESW = suspended standard white

Joiner

BSLJS = suspended joiner

Dust Cover

BSLDCS = 4’ suspended dust cover

Job Information

Type:

Lightolier a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Page 2
Image 2
Lightolier Lighting Systems Baselyte-BSL13, Performance, Module Lengths & Mounting Distances, Run Configuration, Type