Lighting Systems  Baselyte-BSL21

Lighting SystemsBaselyte-BSL21

Page of 7

Performance

Candlepower Curve

 







 

 

 

 



 

 

 

 

 

 

 

 



 

 

 

 



 

 

 

 



 

 

 

 



 

 

 

 



 

 

 

 





 

 

 



 

 

 

 



 

 

 



 

 

 

 

 

 

 

 





 

 

 



 

 

 

 

 

 

 

 





 

 

 



 

 

 

 

 







 

 

 

 

 

 

 

 

Report No: 2101588

Lamps: F32T8

Lumens per Lamp: 2950

Efficiency: 89.6%

Up: 100.0% Down: 0.0%

Candlepower Summary

ZONE

 

CANDLEPOWER

 

DEG.

0

22.5

45

67.5

90

180

639

639

639

639

639

175

636

637

640

641

641

165

613

619

632

641

645

155

571

584

614

639

649

145

507

533

588

633

650

135

427

471

555

622

647

125

331

402

520

605

636

115

225

333

480

560

592

105

114

266

374

388

419

95

25

83

121

102

122

90

1

1

8

1

9

85

0

0

0

0

0

75

0

0

0

0

0

65

0

0

0

0

0

55

0

0

0

0

0

45

0

0

0

0

0

35

0

0

0

0

0

25

0

0

0

0

0

15

0

0

0

0

0

5

0

0

0

0

0

0

0

0

0

0

0

 Light T8 Indirect

Coefficients of Utilization

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

80

 

 

70

 

 

 

50

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

50

30

10

50

30

10

 

50

30

10

0

85

85

85

73

73

73

 

49

49

49

1

74

71

68

63

60

58

 

43

41

40

2

64

59

55

55

51

47

 

37

35

33

3

56

50

46

48

43

39

 

33

30

27

4

49

43

38

42

37

33

 

29

26

23

5

44

37

32

37

32

28

 

26

22

20

6

39

32

27

33

28

24

 

23

19

17

7

35

28

24

30

24

21

 

20

17

14

8

31

25

20

27

21

18

 

18

15

12

9

28

22

18

24

19

16

 

17

13

11

10

26

20

16

22

17

14

 

15

12

10

Zonal Lumen Summary

 

 

ZONE

LUMENS

%BARE LAMP

%LUMINAIRE

0-90

0

0

0

90-180

2645

89.7

100.0

0-180

2645

89.7

100.0

Module Lengths & Mounting Distances

@

-ODULE ,ENGTH ,

-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

Note: Shaded area indicates locations of emergency sections (emergency wiring controls all lamps or optional battery pack controls one or two lamps).

Run Configuration

Run

4’

8’

12’

Joiner

End Set

Mount

Power

Length

Module

Module

Module

Mount*

 

 

 

 

 

 

 

 

 

 

 

4’ run

1

 

 

 

1

1

1

 

 

 

 

 

 

 

 

8’ run

 

1

 

 

1

1

1

 

 

 

 

 

 

 

 

12’ run

 

 

1

 

1

1

1

 

 

 

 

 

 

 

 

16’ run

 

2

 

1

1

2

1

 

 

 

 

 

 

 

 

20’ run

 

1

1

1

1

2

1

 

 

 

 

 

 

 

 

24’ run

 

 

2

1

1

2

1

 

 

 

 

 

 

 

 

28’ run

 

2

1

2

1

3

1

 

 

 

 

 

 

 

 

32’ run

 

1

2

2

1

3

1

 

 

 

 

 

 

 

 

*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.

System Components & Accessories

End Set

BSLESW = suspended standard white

Joiner

BSLJS = suspended joiner

Dust Cover

BSLDCS = 4’ suspended dust cover

Job Information

Type:

Lightolier a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Page 2
Image 2
Lightolier Lighting Systems Baselyte-BSL21, Page of, Performance, Module Lengths & Mounting Distances, Type, End Set