Belmont Spill Frame BESF1X4
Page 2 of 2
Chassis
Model No. BE1W232UNVHI
with shielding BESF1X4
LER = FP - 48.0 IW - 58.87 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $5.00
Report Number: G2008131
Lamp: (2) F32T8
Luminaire: 1X4 Belmont Spill Frame
Ballast:
Report is based on 2850 Lumens per lamp. Efficiency: 56.3%
CIE Type - Direct |
|
| |
Plane: |
| ||
Spacing Criteria: | 1.3 | 1.3 | |
Shielding Angles: | 90 | 90 | |
Plane: |
| ||
Luminous Length: | 48.000 | 9.000 | |
ZONAL LUMEN SUMMARY |
| ||
|
|
|
|
ZONE | LUMENS | % LAMP | % FIXT |
801 | 14.1 | 25.0 | |
1320 | 23.2 | 41.1 | |
2375 | 41.7 | 74.0 | |
3208 | 56.3 | 100.0 | |
0000 | 0.0 | 000.0 | |
3208 | 56.3 | 100.0 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 3535. | 3591. | 3657. |
55 | 3445. | 3552. | 3639. |
65 | 3284. | 3497. | 3666. |
75 | 2938. | 3561. | 4171. |
85 | 2346. | 6091. | 8148. |
CANDELA DISTRIBUTION
|
| 0.0 | 45.0 | 90.0 | FLUX | ||||
0 |
| 1024 | 1024 | 1024 |
|
| |||
5 |
| 1017 | 1018 | 1023 |
| 97 | |||
15 |
| 982 | 986 | 993 | 279 | ||||
25 |
| 915 | 921 | 929 | 425 | ||||
35 |
| 818 | 827 | 836 | 519 | ||||
45 |
| 697 | 708 | 721 | 548 | ||||
55 |
| 551 | 568 | 582 | 508 | ||||
65 |
| 387 | 412 | 432 | 407 | ||||
75 |
| 212 | 257 | 301 | 273 | ||||
85 |
|
| 57 | 148 | 198 | 152 | |||
90 |
|
| 20 | 102 | 150 |
|
| ||
|
|
| |||||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.200 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
01 | 60 | 57 | 55 | 54 | 52 | 50 | 51 | 50 | 48 |
02 | 55 | 50 | 45 | 46 | 43 | 40 | 45 | 42 | 39 |
03 | 50 | 43 | 38 | 41 | 37 | 34 | 39 | 36 | 33 |
04 | 45 | 38 | 33 | 36 | 32 | 28 | 35 | 31 | 28 |
05 | 42 | 34 | 29 | 32 | 28 | 24 | 31 | 27 | 24 |
06 | 38 | 31 | 25 | 29 | 25 | 21 | 28 | 24 | 21 |
07 | 36 | 28 | 23 | 26 | 22 | 19 | 26 | 22 | 19 |
08 | 33 | 25 | 20 | 24 | 20 | 17 | 23 | 19 | 17 |
09 | 31 | 23 | 18 | 22 | 18 | 15 | 22 | 18 | 15 |
10 | 29 | 21 | 17 | 20 | 16 | 14 | 20 | 16 | 14 |
Architectural Surface Fluorescent
Ordering Information
Chase Code:
BE
1
2
32
UNV
Belmont | Fixture Width: | Body Finish: | Lamp |
|
|
| Voltage: |
Lamp: | |||||||
Architectural | 1 = 10 1/2¨ wide | W = White | Quantity | (By Others) | |||
Fluorescent |
| B = Black | 2 = 2 Lamp T8 | 32 = T8 32W |
| ||
|
|
|
| (Nominal 24") |
|
Options:
Add appropriate suffix to catalog no.,
ie: (GLR)
Consult factory for additional options
Ballast Type:
| <10THD |
1 & 2 Lamp Elec. T8 | HI †† |
(32 Watt) |
|
†Instant Start (UNV) |
|
NOTE: Chassis and shielding are packed in separate cartons. When ordering, enter as separate line items.
Length | Shielding | Chassis | Finish | Lamp | Ballast | 10THD |
4' | BESF1X4 | BE1B232UNVHI | Black | 1 - 2 Lamp Elec. | HI | |
4' | BESF1X4 | BE1W232UNVHI | White | 1 - 2 Lamp Elec. | HI |
Specifications
Finish: Chassis
Electrical: Thermally protected class “P” ballast C.B.M. approved, no PCB. If KO is within 3” of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws.
See: www.lamprecycle.org
NOTE: Chassis and shielding shown are stock items.
Job Information Type:
For Factory Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
www.lightolier.com © 2009 a Philips Group | Section 3A/Folio |
Lightolier is a Philips group brand