Calculite® HID Downlight C12E28VN

Page 1 of 2

12" Aperture, ED28 (Enclosed) Metal Halide, Narrow Beam

 

10

8

4

1

2

3

6

7 5 11

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21-1/4" (540 mm) 175-250W 23-3/4" (603 mm) 320-400W

13" (330 mm)

 

 

 

 

 

 

 

 

 

 

20" (508 mm) to 30" (762 mm)

11"

10-3/4"

(280 mm)

(273 mm)

16-3/8" (416 mm)

Top View

18-3/4"

(376 mm)

Vertical Adjustment: 5/8" (16 mm) to 2 7/8" (73 mm)

Ceiling Cutout: 12 9/16” (256 mm) Dia.

12" (305 mm) Dia.

13-1/4" (337 mm) Dia.

2" (50 mm) max. Ceiling Thickness

Reflector Trim

 

Frame-In Kit

Lamp (Enclosed, Coated)

C12E28VN CLW

Specular Clear, White Painted Flange.

C1217MHPU Magnetic Pulse Start, 120V/277V

175W

ED28, BT28, PS MH

CLP

Specular Clear, Matching Flange.

C1225MHPU Magnetic Pulse Start, 120V/277V

250W

ED28, BT28, PS MH

CCDW

Comfort Clear Diffuse, White Painted Flange.

C1232MHPU Magnetic Pulse Start, 120V/277V

320W

ED28, BT28, PS MH

CCDP

Comfort Clear Diffuse, Matching Flange.

C1240MHPU Magnetic Pulse Start, 120V/277V

400W

ED28, BT28, PS MH

CCZW

Champagne Bronze, White Painted Flange.

C1217MHU

Magnetic, 120V/277V

175W

ED28, BT28, MH

CCZP

Champagne Bronze, Matching Flange.

C1225MHU

Magnetic, 120V/277V

250W

ED28, BT28, MH

 

 

C1240MHU

Magnetic, 120V/277V

400W

ED28, BT28, MH

 

 

 

 

 

 

Features

1.Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides narrow beam optics ideal for high ceilings. Also available in wide beam, see C12E28VW specification sheet.

2.Aperture Cone: Low brightness with 40° cut-off to lamp. Specular Clear or Comfort Clear™ Diffuse, or champagne bronze self-flanged in painted white or aperture-matching polished flange. Consult factory for other finishes.

3.Lamp Shield: High-temperature glass as required by code, captive during re-lamping.

4.Socket Cup: Heat dissipating, die-cast aluminum, pre-wired with mogul base porcelain socket with nickel plated screw shell. Postive locking attachment without tools to reflector assures proper optical alignment of lamp.

5.Mounting Frame: 0.048" (18-ga.) galvanized steel. Includes the pre-installed mounting bars.

6.Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures.

7.Retention Springs: Rust resistant springs secure cone for quick, tool-less installation.

8.Frame Vertical Adjustment: Vertical adjustment mechanism accommodates mounting to virtually any ceiling system using mounting bars (provided, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be preset prior to installation.

9.Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories.

10.Ballast: Pulse Start

11.Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below.

12.Thermal Protector: Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.

Electrical

Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, CWA or Super CWA (pulse start) circuit type, high power factor, sound rating “B” (175W and 250W PS)/sound rating “C” (others), -20°F minimum starting Temperature, Type 1 Outdoor rating.

Electrical (cont.)

Ballast

ANSI Code

Voltage

Max. Amps

Input Watts

175W

PS MH

M137

120/277

2.20/0.90

205

250W

PS MH

M138

120/277

2.80/1.20

290

320W

PS MH

M132

120/277

3.40/1.50

370

400W

PS MH

M135

120/277

4.10/1.80

465

175W

MH

M57

120/277

2.00/0.90

205

250W

MH

M58

120/277

2.60/1.10

290

400W

MH

M59

120/277

3.90/1.70

460

Options and Accessories

Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet ”A“.

Emergency: Add suffix E to Reflector Trim and Frame-In Kit. See Spec. Sheet “E”.

Slope Ceiling Adapters: See Specification Sheet SCA.

Fuse (magnetic ballast): Add suffix F1 or F2 to Frame in Kit (F1=120V, F2=277V).

Chicago Plenum: Consult Factory.

Labels

UL (Suitable for Damp Locations), CSA, I.B.E.W.

For 320W/400W, install fixtures with minimum spacing: 4 feet from center-to- center of adjacent luminaries; 3 inch from top of luminaire to overhead building member;2 feet from luminaire center to side building member.

Job Information

Type:

Job Name:

Cat. No.:

Lamp(s): Notes:

Lightolier a Genlyte Thomas Companywww.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4

Page 1
Image 1
Lightolier C12E28VN specifications Aperture, ED28 Enclosed Metal Halide, Narrow Beam, Frame-In Kit, Features, Electrical