Calculite® Evolution Pinhole Downlight  C3MRPD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 2 of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 1/4" Aperture, MR16 (12V)

37W MR16 IR - 40° Flood Sylvania Halogen Lamp, Lumen Rating = 840 LMS, 120V Electronic Transformer

400˚

800˚

1200˚

1600˚

CANDLEPOWER Distribution

60˚

30˚

ANGLE

MEAN CP

LUMENS

 

01524

5

1350

126

10

1069

 

15

813

225

20

485

 

25

139

91

30

24

 

35

7

6

40

1

 

45

0

0

50

0

 

55

0

0

60

0

 

65

0

0

70

0

 

75

0

0

80

0

 

85

0

0

90

0

 

LUMINANCE SUMMARY CD. / SQ.M.

ANGLE

MEAN CD/SQ M

45

0

55

0

65

0

75

0

85

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS

% LAMP

%LUMINAIRE

0-30

442

52.70

98.47

0-40

448

53.42

99.81

0-60

449

53.51

99.97

0-90

449

53.52

100.00

40-90

0

0.10

0.19

60-90

0

0.01

0.03

90-180

0

0.00

0.00

0-180

449

53.52

100.00

Coefficients of Utilization

CEILING

 

 

 

80%

 

 

70%

 

50%

 

30%

 

 

WALL

70

50

30

10

50

10

50

10

50

10

0

 

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

0

 

.64

.64

.64

.64

.62

.62

.59

.59

.57

.57

.54

 

1

 

.62

.61

.60

.60

.60

.59

.58

.57

.56

.55

.53

 

2

 

.60

.59

.58

.57

.58

.56

.56

.55

.55

.54

.52

 

3

 

.59

.57

.56

.54

.56

.54

.55

.53

.54

.52

.51

 

4

 

.58

.56

.54

.53

.55

.52

.54

.52

.53

.51

.50

 

5

 

.57

.54

.52

.51

.54

.51

.53

.50

.52

.50

.49

 

6

 

.56

.53

.51

.50

.53

.50

.52

.49

.51

.49

.48

 

7

 

.54

.52

.50

.49

.51

.48

.51

.48

.50

.48

.47

 

8

 

.53

.50

.49

.48

.50

.47

.50

.47

.49

.47

.46

 

9

 

.52

.49

.48

.46

.49

.46

.49

.46

.48

.46

.46

 

10

 

.51

.48

.47

.45

.48

.45

.48

.45

.48

.45

.45

 

** EFFICIENCY = 53.5% ** SC = .5

CERTIFIED TEST REPORT NO. 2739FR DATE: SEPT 24, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**

LUMINAIRE INPUT WATTS = 38

50W MR16 IR - 40° Flood GE Halogen Lamp, Lumen Rating = 800 LMS, 120V Electronic Transformer

375˚

750˚

1125˚

1500˚

CANDLEPOWER Distribution

60˚

30˚

ANGLE

MEAN CP

LUMENS

 

01391

5

1364

128

10

1234

 

15

944

259

20

539

 

25

166

104

30

31

 

35

7

7

40

2

 

45

0

0

50

0

 

55

0

0

60

0

 

65

0

0

70

0

 

75

0

0

80

0

 

85

0

0

90

0

 

LUMINANCE SUMMARY CD. / SQ.M.

ANGLE

MEAN CD/SQ M

45

0

55

0

65

0

75

0

85

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS

% LAMP

%LUMINAIRE

0-30

491

61.43

98.34

0-40

498

62.36

99.83

0-60

499

62.45

99.97

0-90

499

62.47

100.00

40-90

0

0.11

0.17

60-90

0

0.02

0.03

90-180

0

0.00

0.00

0-180

499

62.47

100.00

Coefficients of Utilization

CEILING

 

 

 

80%

 

 

70%

 

50%

 

30%

 

 

WALL

70

50

30

10

50

10

50

10

50

10

0

 

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

0

 

.74

.74

.74

.74

.73

.73

.69

.69

.66

.66

.62

 

1

 

.72

.71

.70

.70

.70

.68

.68

.66

.65

.64

.62

 

2

 

.70

.69

.67

.66

.68

.65

.66

.64

.64

.63

.60

 

3

 

.69

.67

.65

.63

.66

.63

.64

.62

.63

.61

.60

 

4

 

.67

.65

.63

.61

.64

.61

.63

.60

.62

.60

.58

 

5

 

.66

.63

.61

.59

.62

.59

.61

.59

.61

.58

.57

 

6

 

.65

.62

.59

.58

.61

.58

.60

.57

.60

.57

.56

 

7

 

.63

.60

.58

.56

.60

.56

.59

.56

.58

.56

.55

 

8

 

.62

.59

.57

.56

.58

.55

.58

.55

.57

.55

.54

 

9

 

.61

.57

.55

.54

.57

.54

.57

.54

.56

.53

.53

 

10

 

.59

.56

.54

.53

.56

.53

.55

.53

.55

.52

.52

 

** EFFICIENCY = 62.5% ** SC = .6

CERTIFIED TEST REPORT NO. 2720FR DATE: SEPT 5, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**

LUMINAIRE INPUT WATTS = 51

50W MR16 IR - 40° Flood Sylvania Halogen Lamp, Lumen Rating = 1125 LMS, 120V Electronic Transformer

CANDLEPOWER Distribution

500˚

60˚

 

1000˚

 

1500˚

 

2000˚

30˚30

ANGLE

MEAN CP

 

LUMENS

 

 

0

2041

 

5

1808

169

10

1433

 

15

1089

302

20

650

 

25

186

122

30

33

 

35

9

8

40

2

 

45

1

1

50

1

 

55

1

1

60

0

 

65

0

0

70

0

 

75

0

0

80

0

 

85

0

0

90

0

 

LUMINANCE SUMMARY CD. / SQ.M.

ANGLE

MEAN CD/SQ M

45

0

55

0

65

0

75

0

85

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS

% LAMP

%LUMINAIRE

0-30

593

52.72

98.39

0-40

601

53.45

99.75

0-60

602

53.57

99.97

0-90

602

53.59

100.00

40-90

1

0.13

0.25

60-90

0

0.02

0.03

90-180

0

0.00

0.00

0-180

602

53.59

100.00

Coefficients of Utilization

CEILING

 

 

 

80%

 

 

70%

 

50%

 

30%

 

 

WALL

70

50

30

10

50

10

50

10

50

10

0

 

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

.64

.64

.64

.64

.62

.62

.60

.60

.57

.57

.54

 

1

 

.62

.61

.60

.60

.60

.59

.58

.57

.56

.55

.53

 

2

 

.60

.59

.58

.57

.58

.56

.56

.55

.55

.54

.52

 

3

 

.59

.57

.56

.54

.56

.54

.55

.53

.54

.52

.51

 

4

 

.58

.56

.54

.53

.55

.52

.54

.52

.51

.51

.50

 

5

 

.57

.54

.52

.51

.54

.51

.53

.50

.52

.50

.49

 

6

 

.56

.53

.51

.50

.53

.50

.52

.49

.51

.49

.48

 

7

 

.54

.52

.50

.49

.51

.48

.51

.48

.50

.48

.47

 

8

 

.53

.50

.49

.48

.50

.47

.50

.47

.49

.47

.46

 

9

 

.52

.49

.48

.46

.49

.46

.49

.46

.48

.46

.46

 

10

 

.51

.48

.47

.45

.48

.45

.48

.45

.48

.45

.45

 

** EFFICIENCY = 53.6% **

SC = .5

CERTIFIED TEST REPORT NO. 2721FR DATE: SEPT 5, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**

LUMINAIRE INPUT WATTS = 51

Job Informationv

Type:

 

 

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group •F0408

Lightolier is a Philips group brand

Page 2
Image 2
Lightolier C3MRPD specifications Ceiling, Wall RCR, Luminaire Input Watts =, Angle Mean CP Lumens

C3MRPD specifications

The Lightolier C3MRPD is a sophisticated lighting fixture designed to enhance both residential and commercial spaces. This versatile product offers a plethora of features and technologies that make it a preferred choice among designers and architects.

One of the standout features of the C3MRPD is its energy efficiency. Utilizing advanced LED technology, this fixture provides powerful illumination while significantly reducing energy consumption compared to traditional lighting options. The LED modules not only ensure lower utility costs but also have a longer lifespan, minimizing the need for frequent replacements.

The C3MRPD employs innovative optics that allow for superior light distribution. The fixture is designed to produce a uniform light output, eliminating harsh shadows and creating a more inviting atmosphere in any room. This is particularly beneficial in spaces where visual tasks are performed, such as offices, kitchens, and retail environments.

Another characteristic of the C3MRPD is its versatility in application. This fixture can be recessed, surface-mounted, or used in pendant configurations, adapting seamlessly to various design schemes and architectural requirements. Its sleek and modern design ensures it complements a wide range of interiors, from contemporary styles to more traditional spaces.

The fixture's adjustable features also provide users with unique customization options. With the ability to tilt and rotate, the C3MRPD can direct light exactly where it’s needed, making it ideal for highlighting artwork or architectural details. This flexibility makes it suitable for multiple environments, from galleries to homes.

Moreover, the C3MRPD incorporates advanced control technology that allows users to manage their lighting with ease. Options for dimming and smart lighting integration, such as compatibility with home automation systems, provide user-friendly control over the ambiance of a space.

In summary, the Lightolier C3MRPD is a remarkable lighting solution that combines energy efficiency, adaptability, and modern design. Its advanced LED technology, superior optics, and customizable features make it an excellent choice for anyone looking to enhance their lighting experience. Whether for residential or commercial applications, the C3MRPD stands out as a reliable and aesthetically pleasing option for modern lighting needs.